N/A A71200
Ref A71200
Active
Valid until
2 Jul 2030
FDA recalls
4 ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0199309B0000032JW 00763000520083 | Date23 Jul 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00763000520083 | Date23 Jul 2021 | StatusListed |
Certificates
- G70 039709 1296 Active
Technical documentation EU MDR
- Certifier
- TÜV SÜD Product Service GmbH 0123
- Issued
- 15 Jun 2026
- Expires
- 2 Jul 2030
- Reason
- Change approved
Recalls
-
- Ongoing Z-0372-2025
The Wireless Rechargers in the kits may be unable to enter a recharging session upon first use.
-
- Ongoing Z-1691-2024
inability to reprogram one device
-
- Ongoing Z-0780-2024
Medtronic has discovered an instance in which the Intellis A710 Clinician Programmer Application (CP App) could no longer establish a session with the Implantable Neurostimulator (INS) which resulted in the inability for the clinician to adjust stimulation parameters. In the event of this issue, the patient may receive inadequate or excessive therapy and experience non-optimal pain relief.
-
- Ongoing Z-2159-2021
Specific PINs of the Vectris SureScan MRI lead kits contain the incorrect lead electrode spacing information printed on the shelf box and the sterile pack labeling.
-
- Terminated Z-1926-2016
Loss of therapy during recharging of device. Reportedly, a charging session was terminated prior to obtaining recharge threshold voltage of 3.615, which triggered rapid battery depletion state. As a result, the device depleted to 1.925 volts in one to two days rather than the typical 30 days. Insufficient coupling between recharger and device during recharge session was found to be key factor.
-
- Terminated Z-1147-2015
Current labeling indicates that cycling improves device longevity in every programming scenario. However, enabling cycling at certain parameter settings may decrease the device battery longevity. With cycling enabled, longevity estimate displayed on the Model 8840Programmer may be inaccurate.
-
- Terminated Z-1524-2014
Medtronic neurostimulators (used with pain and deep brain stimulation therapy) have a cycling feature that, when enabled, allows stimulation output to be toggled on and off based on the programmed settings. The use of this feature is determined by the physician and set using the clinician programmer. Current labeling indicates the use of cycling improves device longevity and recharge interval
-
- Terminated Z-0278-2014
Medtronic notified customers regarding Loss of Stimulation of specific Implantable Neuro-Stimulators under the following specific conditions: Switching between groups with Multiple programs or creating program groups. Therapy can be restored with the Physician Recharge mode (RPM) of the Implantable Neurostimulator Recharger (INSR).
-
- Terminated Z-1536-06
Model 3777 Standard Octad Lead (Lot V009545) and Model 3778 Compact Octad Lead (Lot V009546) were mispackaged. The result of this error is that lead kits labeled 3777 lot V009545 may contain a 3778 compact-spaced lead, while those labeled 3778 lot V009546 may contain a 3777 standard-spaced lead. The result of this error is an overall increase or decrease of 14 mm in the electrode coverage.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Vanta™ / Sequentia™
- Generic Name
- Multiple active implantable device programmer
- Device Name
- Clinician Programmer Application
- Model / Reference
- A71200
- Primary DI / UDI-DI
- 00763000520083
- Basic UDI-DI
- 0199309B0000032JW
- PMA Number
- FDA Product Code
- LGW, QRB
- EMDN Code
- J020782 Neurostimulators programmers - software accessories
- GMDN Term
- Multiple active implantable device programmer
- Device Class
- Class III
- Special Device Type
- Software
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Other devices from Medtronic, Inc.
Properties
Other properties (22)
- Sterile: No
- Single Use: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Measuring Function: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Expiration Date: No
- Manufacturing Date: No