113-03-01
113-03-01 is an orthopaedic implant impactor (FDA Class II) made by Exactech, Inc., cleared under FDA 510(k) K173583 on 12 Mar 2018 (6 earlier submissions) and listed in FDA GUDID since 28 Jul 2022 (UDI-DI 10885862016850), active as of 23 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
4 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10885862016850 | Date28 Jul 2022 | StatusListed |
| United States | FDA 510(k)SESE | NumberK173583 | Date12 Mar 2018 | StatusActive |
Official records
- AccessGUDID record 10885862016850
- FDA 510(k) database K173583
- FDA 510(k) database K103012
- FDA 510(k) database K060107
- FDA 510(k) database K050398
- FDA 510(k) database K051682
- FDA 510(k) database K041906
- FDA 510(k) database K032964
From the FDA record
- Device description
- FEMORAL HEAD IMPACTOR
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K173583 decided 12 Mar 2018 Active
- FDA GUDID UDI-DI 10885862016850 listed 28 Jul 2022 Listed
Recalls
-
- Ongoing Z-1166-2025
- Ongoing Z-1165-2025
Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer.
-
- Ongoing Z-0577-2024
Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.
-
- Ongoing Z-1727-2022
Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear.
-
- Completed Z-2251-2021
- Completed Z-2250-2021
Biolox Delta Femoral Head was packaged and labeled as 170-36-00 (36mm +0), but the device was marked as 170-36-03 (36mm +3.5).
-
- Terminated Z-0572-2008
Mislabeled: A ten piece lot of 140-32-03, 12/14 BIOLOXforte Alumina Femoral Heads 32mm (1069020 - 1069029), from Ceramtec were incorrectly labeled as 140-28-03 12/14 BIOLOXforte Alumina Femoral Heads, 28mm
Timeline
- Recall initiated FDA recalls Z-0572-2008
- Cleared FDA 510(k) K103012
- Cleared FDA 510(k) K173583
- Recall initiated FDA recalls Z-2251-2021
- Recall initiated FDA recalls Z-2250-2021
- Listed FDA GUDID 10885862016850
- Recall initiated FDA recalls Z-1727-2022
- Recall initiated FDA recalls Z-0577-2024
- Recall initiated FDA recalls Z-1166-2025
- Recall initiated FDA recalls Z-1165-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Orthopaedic implant impactor, reusable
- Model / Ref / Catalog
- 113-03-01
- Primary DI / UDI-DI
- 10885862016850
- FDA product code
- JDI, LWJ, LPH, LZO, MEH, OQI
- GMDN term
- Orthopaedic implant impactor, reusable
- Device class
- Class II
- Regulation number
- 888.3350, 888.3360, 888.3358, 888.3353
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices in this category
Other devices filed under Orthopaedic implant impactor, reusable.
- CUP IMPACTOR 4.0 M8x1 H0034300099 by HPF SRL
- Threaded Drill Guide C09077 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- ACCESSORY TRACKER H0034000499 by HPF SRL
- MobiliT Cup MDM002 by CORIN LTD
- Versa-Dial® Shoulder System 407297 by Biomet Orthopedics, Inc.
- Femoral Intercondylar Cutting Block (5#) E02130 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- WasherCap™ Inserter 9mm & 10mm ATMWCIN 42 by ABANZA TECNOMED, S.L.
- Persona® 42-5099-091-00 by Zimmer, Inc.
- INFINITY 33600141 by WRIGHT MEDICAL TECHNOLOGY, INC.
- MobiliT Cup MDM001 by CORIN LTD