Baxter 1C8627
by Baxter Healthcare Corp GUDID
Listed (no authorization)
Regulatory status
Recall ongoing. 7 ongoing FDA recalls. See recalls
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00085412031859 | Date24 Sep 2016 | StatusIn distribution |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not known
- Not covered
United States — GUDID listing Listed
Recalls
-
- Ongoing Z-0194-2026
- Ongoing Z-0192-2026
- Ongoing Z-0193-2026
IV sets may leak.
-
- Ongoing Z-2594-2025
Baxter Healthcare Corporation is issuing an Urgent Medical Device Recall for one lot of Continu-Flo solution sets listed below due to customer reports of tubing separation.
-
- Ongoing Z-1011-2025
Specific lots of Solution Sets with Duo-Vent Spike have the potential for inverted side clamps causing the tubing to be unusable.
-
- Ongoing Z-0794-2020
- Ongoing Z-0793-2020
Continu-Flo sets with male Luer bodies at the lower end of, and within, the ISO specification for outer diameter require a higher than expected connection force to fully inset and securely tighten the Luer to the ONE-LINK connector.
-
- Terminated Z-0475-2012
During production of the IV sets, solvent was inadvertently applied to the locking collar of the male luer connector, which may have damaged the component, preventing proper engagement of the locking collar to secure a connection.
-
- Terminated Z-2920-2011
The Solution Sets are being recalled because the position of the slide clamp and roller clamp may have been reversed during assembly. The reversed orientation of the slide clamp and roller clamp will cause the set to be incorrectly loaded into an infusion pump, resulting in fluid flow from the patient to the pump, rather than from the pump to the patient.
-
- Terminated Z-0653-06
The extension sets contain microbore female luers that may crack during use, resulting in leakage of medication or incomplete delivery of medication.
-
- Terminated Z-0845-05
Possible occlusion of the Clearlink injection site valve due to inadequate silicone lubrication of the slit in the upper seal of the valve.
-
- Terminated Z-1152-03
There are possible pinholes or perforations in the set tubing, caused by damage that occurred during the packaging process.
Specification
- Trade Name
- Baxter
- Generic Name
- Basic intravenous administration set, noninvasive
- Model / Ref / Catalog
- 1C8627
- Primary DI / UDI-DI
- 00085412031859
- FDA Product Code
- FPA
- GMDN Term
- Basic intravenous administration set, noninvasive
- Device Class
- Class II
- Regulation Number
- 880.5440
- Commercial Distribution
- In Commercial Distribution