RSDSTR10G
RSDSTR10G, an intracardiac ultrasound imaging catheter (FDA Class II; FDA product code OWQ, Reprocessed intravascular ultrasound catheter) made by Sterilmed, Inc., was cleared under FDA 510(k) K110076 on 18 Aug 2011 and listed in FDA GUDID on 22 Sep 2016 (UDI-DI 10888551044370); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 1.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10888551044370 | Date22 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK110076 | Date18 Aug 2011 | StatusActive |
Official records
- AccessGUDID record 10888551044370
- FDA 510(k) database K110076
From the FDA record
- Device description
- REPROCESS SDSTR 10F-90 GE
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile; sterilise before use (Ethylene Oxide)
Across registries
- FDA 510(k) K110076 decided 18 Aug 2011 Active
- FDA GUDID UDI-DI 10888551044370 listed 22 Sep 2016 Listed
Recalls
-
- Terminated Z-0059-2015
Sterilmed, a division of Johnson & Johnson Medical NV/SA (Sterilmed), has become aware of an issue affecting certain lots of Reprocessed SOUNDSTAR® eco Diagnostic Ultrasound Catheters for which Sterilmed is the reprocessor and Biosense Webster is the distributor. Sterilmed determined that the units of these lots were incorrectly processed and as a result when the affected catheter is conne
Timeline
- Cleared FDA 510(k) K110076
- Recall initiated FDA recalls Z-0059-2015
- Listed FDA GUDID 10888551044370
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Intracardiac ultrasound imaging catheter, steerable, reprocessed
- Model / Ref / Catalog
- RSDSTR10G
- Primary DI / UDI-DI
- 10888551044370
- 510(k) Number
- FDA product code
- OWQ
- GMDN term
- Intracardiac ultrasound imaging catheter, steerable, reprocessed
- Device class
- Class II
- Regulation number
- 870.1200
- GUDID distribution status
- Not in Commercial Distribution
- Sterilisation method
- Ethylene Oxide
Similar devices
Other devices filed under FDA product code OWQ (Reprocessed intravascular ultrasound catheter).
- NES Reprocessed Eagle Eye Platinum RX Digital IVUS Catheter by NORTHEAST SCIENTIFIC, INC.
- Reprocessed SoundStar 3D Diagnostic Ultrasound Catheter by INNOVATIVE HEALTH, LLC.
- Reprocessed ViewFlex Xtra ICE Catheter (D087031) by Stryker Sustainability Solutions
- REPROCESSED DIAGNOSTIC ULTRASOUND CATHETER by Alliance Medical, Inc.
- NES Reprocessed Visions PV .018 Digital IVUS Catheter (R-86700) by NORTHEAST SCIENTIFIC, INC.
- Reprocessed Eagle Eye Platinum RX Digital IVUS Catheter by INNOVATIVE HEALTH, LLC.
- Medline ReNewal Reprocessed Siemens ACUSON AcuNav 8F Ultrasound Catheter (for Siemens Systems) (10135936); Medline ReNewal Reprocessed Siemens ACUSON AcuNav 8F Ultrasound Catheter (for GE Systems) (10135910) by Surgical Instruments Service and Savings, Inc.
- Reprocessed ViewFlex Xtra ICE Catheter by Stryker Sustainability Solutions
- REPROCESSED 3D DIAGNOSTIC ULTRASOUND CATHETERS, MODEL SNDSTR10 by Ascent Healthcare Solutions
- Vein360 Reprocessed Visions PV.014P Rx Digital IVUS Catheter, Vein360 Reprocessed Eagle Eye Platinum Rx Digital IVUS Catheter, Vein360 Reprocessed Eagle Eye Platinum ST Rx Digital IVUS Catheter by Vein 360, LLC