WB-2201-R
by Hangzhou Tappa Medical Technology Co., Ltd. 2 variants
WB-2201-R is a medical device (FDA Class II; FDA product code DWJ, System, Thermal Regulating) made by Hangzhou Tappa Medical Technology Co., Ltd., cleared under FDA 510(k) K252861 on 7 Apr 2026 and listed in FDA GUDID since 30 Jun 2026 (UDI-DI 06950456320921), active as of 22 Oct 2026.
Active
510(k)
Valid until
No expiry
FDA recalls
None found
Documents
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number06950456320921 | Date30 Jun 2026 | StatusListed |
| United States | FDA 510(k)SESE | NumberK252861 | Date7 Apr 2026 | StatusActive |
Official records
- AccessGUDID record 06950456320921
- FDA 510(k) database K252861
From the FDA record
- Device description
- Pediatric Underbody Blanket
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K252861 decided 7 Apr 2026 Active
- FDA GUDID UDI-DI 06950456320921 listed 30 Jun 2026 Listed
Timeline
- Cleared FDA 510(k) K252861
- Listed FDA GUDID 06950456320921
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- External circulating-air core temperature regulation system control unit, heating/cooling
- Model / Ref / Catalog
- WB-2201-R
- Primary DI / UDI-DI
- 06950456320921
- 510(k) Number
- FDA product code
- DWJ
- GMDN term
- External circulating-air core temperature regulation system control unit, heating/cooling
- Device class
- Class II
- Regulation number
- 870.5900
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Similar devices
Other devices filed under FDA product code DWJ (System, Thermal Regulating).
- HEMOTHERM MODEL 400 by Cincinnati Sub-Zero
- PATIENT HEATER SYSTEM, MODEL PH112 by Carolina Medical Electronics
- BLANKETROL II HYPER-HYPOTHERMIA TEMPERATURE MANAGMENT SYSTEM by Cincinnati Sub-Zero Products, Inc.
- The IQoolTM System by BrainCool AB
- ALLON 2001 MODIFIED by Mtre Advanced Technology, Ltd.
- WESCO BLANKET by Wesco, Inc.
- SOFT AIR, MODEL SA 4000 AND MISTRAL AIR, MODEL MA0100 by Adroit Medical Systems, Inc.
- BAIR HUGGER(R) PATIENT WARMING SYSTEM-MODIFICATION by Augustine Medical, Inc.
- RK2000 K-THERMIA SYSTEM by Baxter Healthcare Corp
- KIMBERLY-CLARK PATIENT WARMING SYSTEM - MODEL 100 CONTROL UNIT AND ENERGY TRANSFER PADS by KIMBERLY-CLARK CORPORATION
Other devices from Hangzhou Tappa Medical Technology Co., Ltd.
See all devices from Hangzhou Tappa Medical Technology Co., Ltd. →