Skip to content

Neodent 135.333-ET

by JJGC Indústria e Comércio de Materiais Dentários S/A.

Part of a family of 266 devices: see the family page

Ref 135.333-ETModel Abutment

Neodent 135.333-ET is a dental implant suprastructure (EU MDR Class IIb; FDA Class II; FDA product code NHA, Abutment, implant, dental, endosseous) made by JJGC Indústria e Comércio de Materiais Dentários S/A., registered in EUDAMED on 6 May 2026 (Basic UDI-DI 987800076VY), cleared under FDA 510(k) K163194 on 14 Jul 2017 and listed in FDA GUDID since 10 Aug 2023 (UDI-DI 07899878036869), active as of 7 Nov 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

4 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K163194

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number987800076VY Basic UDI-DI 07899878036869UDI-DIDate6 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number07899878036869 UDI-DI Date10 Aug 2023ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK163194 Date14 Jul 2017DecidedStatusActive

Official records

From the FDA record

Device description
GM TITANIUM BASE AS
MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 987800076VY registered 6 May 2026 Active
  • FDA 510(k) K163194 decided 14 Jul 2017 Active
  • FDA GUDID UDI-DI 07899878036869 listed 10 Aug 2023 Listed

Recalls

6 recalls · 4 ongoing · FDA

    • Ongoing Z-3173-2026 FDA Class II initiated 12 Aug 2026 on shared 510(k) K163194

    There is a discrepancy between the product identification on the packaging and the dimensions of the implant contained inside.

    • Ongoing Z-2929-2026 FDA Class II initiated 13 Jul 2026

    There may be a mismatch between the implant contained inside the packaging and the information described on the outer carton label. If the the incorrect implant is installed, the issue could cause bone compression or difficulty during installation in situations where there is sufficient bone volume

  • 2 recalls, same reason

    • Ongoing Z-1862-2025 FDA Class II initiated 1 May 2025 on shared 510(k) K163194
    • Ongoing Z-1863-2025 FDA Class II initiated 1 May 2025 on shared 510(k) K163194

    It is possible that a package labelled as an 11.5 mm implant may contain a 13 mm implant instead.

    • Terminated Z-0203-2022 FDA Class II initiated 11 Oct 2021 on shared 510(k) K163194

    3.5x11.5mm implants were mislabeled as 3.5x10mm implants. In borderline cases where the bone quality is low and the bone ridge has a maximum indication for the implant height (10mm), if the incorrect implant is installed, it could result in damage to the nerve or adjacent bone structures/cavities.

    • Terminated Z-0455-2019 FDA Class II initiated 2 Oct 2018 on shared 510(k) K163194

    Laser engraved label does not match with the item in the package

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

9 dated events

  1. Cleared FDA 510(k) K163194
  2. Recall initiated FDA recalls Z-0455-2019
  3. Recall initiated FDA recalls Z-0203-2022
  4. Listed FDA GUDID 07899878036869
  5. Recall initiated FDA recalls Z-1862-2025
  6. Recall initiated FDA recalls Z-1863-2025
  7. Registered EUDAMED 987800076VY
  8. Recall initiated FDA recalls Z-2929-2026
  9. Recall initiated FDA recalls Z-3173-2026

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Neodent
Generic name
Dental implant suprastructure, permanent, preformed
Device name
Digital System Abutments
Model / Ref / Catalog
135.333-ET, Abutment
Primary DI / UDI-DI
07899878036869
Basic UDI-DI
987800076VY
FDA product code
NHA
EMDN code
P01020180 Dental implants - accessories
GMDN term
Dental implant suprastructure, permanent, preformed
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
872.3630
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Conditional
Size
Outer Diameter — 4.5 Millimeter

Truth per registry

2 sources · 3 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II
Sterilise before useEUDAMED
No
GUDID
Yes
ImplantableEUDAMED
No
GUDID
Yes

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Sterilise before use UDI-DI 07899878036869: EUDAMED states No, FDA GUDID states Yes.

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under DENTAL IMPLANTS - ACCESSORIES.

Other devices from JJGC Indústria e Comércio de Materiais Dentários S/A.

See all devices from JJGC Indústria e Comércio de Materiais Dentários S/A. →

Properties

  • Supplied sterile
  • Sterilise before use NoEUDAMEDYesGUDID
  • Single use
  • Implantable NoEUDAMEDYesGUDID
  • Prescription use
  • Lot / batch number
  • Serial number
  • Expiration date
  • Manufacturing date
Other properties (16, all answered No)