Skip to content

Nexframe DB-2040-00780

by Fhc, Inc.

Ref DB-2040

Nexframe DB-2040-00780 is a neurological stereotactic surgery system (EU MDR Class IIa; FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Fhc, Inc., registered in EUDAMED on 28 Oct 2026 (Basic UDI-DI 087326300.03-100-1-A.TB), cleared under FDA 510(k) K012366 on 1 Oct 2001 and listed in FDA GUDID since 5 Nov 2020 (UDI-DI 00873263007808), active as of 7 Nov 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K012366

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number087326300.03-100-1-A.TB Basic UDI-DI 00873263007808UDI-DIDate28 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00873263007808 UDI-DI Date5 Nov 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK012366 Date1 Oct 2001DecidedStatusActive

Official records

From the FDA record

Device description
Bilateral Nexframe System for Medtronic StealthStation Navigation Systems
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 087326300.03-100-1-A.TB registered 28 Oct 2026 Active
  • FDA 510(k) K012366 decided 1 Oct 2001 Active
  • FDA GUDID UDI-DI 00873263007808 listed 5 Nov 2020 Listed

Recalls

1 recall · FDA

    • Terminated Z-0849-2008 FDA Unclassified (pre-2012) initiated 4 Oct 2007

    Sterilty (package integrity) Compromised: Some failures were for damage to the outer pouch, while another set of failures were for the seals on this pouch. The seal between the inner tray and lid has not been compromised and the contents remain sterile, however, the sterility of the outer surfaces of the inner tray and lid cannot be assured.

Timeline

4 dated events

  1. Cleared FDA 510(k) K012366
  2. Recall initiated FDA recalls Z-0849-2008
  3. Listed FDA GUDID 00873263007808
  4. Registered EUDAMED 087326300.03-100-1-A.TB

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Nexframe® Sterotactic System EUDAMED
Nexframe GUDID
Generic name
Neurological stereotactic surgery system
Model / Ref / Catalog
DB-2040, DB-2040-00780
Primary DI / UDI-DI
00873263007808
Basic UDI-DI
087326300.03-100-1-A.TB
510(k) Number
FDA product code
HAW
EMDN code
Z12100685 Stereotactic neurosurgery instruments - consumables
GMDN term
Neurological stereotactic surgery system
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
882.4560
EU registration type
Standard device
EU market of registration
Romania
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide
MRI safety
MR Unsafe

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
DB-2040
GUDID
DB-2040-00780
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under STEREOTACTIC NEUROSURGERY INSTRUMENTS - CONSUMABLES.

Other devices from Fhc, Inc.

See all devices from Fhc, Inc. →

Properties

  • Supplied sterile
  • Sterilise before use
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)