Identity
- Trade Name
- NHancer Rx FDA UDI
- Generic Name
- Vascular guide-catheter, single-use FDA UDI
- Device Name
- The NHancer™Rx is a dual lumen catheter intended to use in the coronary and/or peripheral vasculature. The NHancer™Rx is a 0.014” Rapid Exchange (Rx) guide wire support catheter. The NHancer™Rx has an over the wire (OTW) lumen that runs the length of the catheter and a rapid exchange (RX) delivery lumen on the distal end. The NHancer™Rx has an effective length of 135 cm and is compatible with 0.014”/0.36mm or smaller guide wires. The NHancer™Rx has two depth markings located at 95 cm and 105 cm from the distal tip. The NHancer™Rx has a radiopaque marker identifying the distal end of the catheter and a second radiopaque marker located 8 mm from the distal tip identifies the distal end of the OTW lumen. To reduce friction in the guide catheter and vasculature, the distal 15 cm of the shaft is fitted with a hydrophilic coating. To reduce friction of the guide wire in the lumen, the entire lumens of the NHancer Rx are coated with MDX (silicone) coating. To ease catheter loading into the hemostasis device and the guiding catheter a removable stylet (9) is placed in the OTW lumen FDA UDI
- Model / Reference
- NRX1413518 FDA UDI
- Description
- The NHancer™Rx is a dual lumen catheter intended to use in the coronary and/or peripheral vasculature. The NHancer™Rx is a 0.014” Rapid Exchange (Rx) guide wire support catheter. The NHancer™Rx has an over the wire (OTW) lumen that runs the length of the catheter and a rapid exchange (RX) delivery lumen on the distal end. The NHancer™Rx has an effective length of 135 cm and is compatible with 0.014”/0.36mm or smaller guide wires. The NHancer™Rx has two depth markings located at 95 cm and 105 cm from the distal tip. The NHancer™Rx has a radiopaque marker identifying the distal end of the catheter and a second radiopaque marker located 8 mm from the distal tip identifies the distal end of the OTW lumen. To reduce friction in the guide catheter and vasculature, the distal 15 cm of the shaft is fitted with a hydrophilic coating. To reduce friction of the guide wire in the lumen, the entire lumens of the NHancer Rx are coated with MDX (silicone) coating. To ease catheter loading into the hemostasis device and the guiding catheter a removable stylet (9) is placed in the OTW lumen FDA UDI
Identifiers
- Catalog Number
- NRX1413518 FDA UDI
- Primary DI / UDI-DI
- 08718481740231 FDA UDI
- 510(k) Number
- K200324 FDA UDI
- FDA Product Code
- DQY FDA UDI
- GMDN Term
- Vascular guide-catheter, single-use FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 870.1250 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
Yes
FDA UDI
Single Use
Yes
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
No
FDA UDI
Category: Vascular guide-catheter, single-use
NHancer Rx by IMDS Operations B.V. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Vascular guide-catheter, single-use.
- Launcher — MEDTRONIC, INC. · Class II
- Launcher™ — MEDTRONIC, INC. · Class II
- SHERPA NX BALANCED — MEDTRONIC, INC. · Class II
- Surefire Guiding Catheter — Surefire Medical, Inc. · Class II
- SHERPA NX BALANCED™ — MEDTRONIC, INC. · Class II
- Zebra — QApel Medical, Inc. · Class II
- Mach1™ — Boston Scientific · Class II
- SHERPA NX BALANCED — MEDTRONIC, INC. · Class II
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- IMDS Operations B.V.
Sources (1)
- FDA UDI e7d82ae7-23fc-47bc-ab2a-3fb234db6a80 35 fields · synced May 30, 2026