NHancer Rx NRX1413518
NHancer Rx NRX1413518 is a vascular guide-catheter (FDA Class II; FDA product code DQY, Catheter, Percutaneous) made by IMDS Operations B.V., cleared under FDA 510(k) K200324 on 6 Aug 2020 and listed in FDA GUDID since 1 Sep 2022 (UDI-DI 08718481740231), active as of 23 Oct 2026.
Active
510(k)
Valid until
No expiry
FDA recalls
None found
Documents
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number08718481740231 | Date1 Sep 2022 | StatusListed |
| United States | FDA 510(k)SESE | NumberK200324 | Date6 Aug 2020 | StatusActive |
Official records
- AccessGUDID record 08718481740231
- FDA 510(k) database K200324
From the FDA record
- Device description
- The NHancer™Rx is a dual lumen catheter intended to use in the coronary and/or peripheral vasculature. The NHancer™Rx is a 0.014” Rapid Exchange (Rx) guide wire support catheter. The NHancer™Rx has an over the wire (OTW) lumen that runs the length of the catheter and a rapid exchange (RX) delivery lumen on the distal end. The NHancer™Rx has an effective length of 135 cm and is compatible with 0.014”/0.36mm or smaller guide wires. The NHancer™Rx has two depth markings located at 95 cm and 105 cm from the distal tip. The NHancer™Rx has a radiopaque marker identifying the distal end of the catheter and a second radiopaque marker located 8 mm from the distal tip identifies the distal end of the OTW lumen. To reduce friction in the guide catheter and vasculature, the distal 15 cm of the shaft is fitted with a hydrophilic coating. To reduce friction of the guide wire in the lumen, the entire lumens of the NHancer Rx are coated with MDX (silicone) coating. To ease catheter loading into the hemostasis device and the guiding catheter a removable stylet (9) is placed in the OTW lumen
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K200324 decided 6 Aug 2020 Active
- FDA GUDID UDI-DI 08718481740231 listed 1 Sep 2022 Listed
Timeline
- Cleared FDA 510(k) K200324
- Listed FDA GUDID 08718481740231
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- NHancer Rx
- Generic name
- Vascular guide-catheter, single-use
- Model / Ref / Catalog
- NRX1413518
- Primary DI / UDI-DI
- 08718481740231
- 510(k) Number
- FDA product code
- DQY
- GMDN term
- Vascular guide-catheter, single-use
- Device class
- Class II
- Regulation number
- 870.1250
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Vascular guide-catheter, single-use.