Nmct 870 Dr

by GE Medical Systems Israel, Functional Imaging

Ref H3100AP, H3100AR, H3906ED, H3906EM, H3906EN, H3906EPModel NM/CT 870 DR

Nmct 870 Dr is a device classified as Class IIb in the EU and Class II in the US made by GE Medical Systems Israel, Functional Imaging, registered in EUDAMED on 15 Oct 2026 (Basic UDI-DI B-00840682140836), cleared under FDA 510(k) K093514 on 10 Dec 2009 and listed in FDA GUDID since 17 May 2018 (UDI-DI 00840682140836), active as of 24 Oct 2026. 21 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

6 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K093514

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00840682140836 Basic UDI-DI 00840682140836UDI-DIDate15 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00840682140836 UDI-DI Date17 May 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK093514 Date10 Dec 2009DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00840682140836 registered 15 Oct 2026 Active
  • FDA 510(k) K093514 decided 10 Dec 2009 Active
  • FDA GUDID UDI-DI 00840682140836 listed 17 May 2018 Listed

Recalls

21 recalls · 6 ongoing · FDA

  • 4 recalls, same reason

    • Ongoing Z-0895-2025 FDA Class II initiated 18 Dec 2024
    • Ongoing Z-0894-2025 FDA Class II initiated 18 Dec 2024
    • Ongoing Z-0893-2025 FDA Class II initiated 18 Dec 2024
    • Ongoing Z-0891-2025 FDA Class II initiated 18 Dec 2024

    GE HealthCare has become aware that certain Infinia, VariCam/VG/VH, Brivo NM 615, Discovery NM 630, Discovery NM/CT 670, and Optima NM/CT 640 Nuclear Medicine systems (see Affected Products Details and Appendices) could have been transported or relocated without proper detector support, which can result in excessive load being applied to the detector mounting mechanisms. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury.

    • Ongoing Z-1053-2023 FDA Class I initiated 19 Dec 2022

    A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury.

    • Ongoing Z-1547-2021 FDA Class II initiated 7 Feb 2021

    GE Healthcare has become aware of a potential issue on 800 family NM/CT Scanners that could cause a shift in CT radiation exposure range of up to 5cm compared to the intended radiation exposure range of the planned scan under specific workflows. The issue occurs only on a hybrid whole-body continuous F3 protocol with Zoom < 1 where the scan range is set on the Smart Console. In some cases, this may also necessitate a re-scan of the patient, which would expose the patient to additional X-ray radiation.

    • Terminated Z-0857-2021 FDA Class II initiated 10 Dec 2020

    GE Healthcare has become aware that rotor bearing screws were found loose on one detector in the field, leading to the release of one of the four rotor bearings in the detector.

  • 3 recalls, same reason

    • Terminated Z-2998-2020 FDA Class II initiated 14 Aug 2020
    • Terminated Z-2996-2020 FDA Class II initiated 14 Aug 2020
    • Terminated Z-2997-2020 FDA Class II initiated 14 Aug 2020

    Rotor bearing screws were found loose on detector.

  • 3 recalls, same reason

    • Terminated Z-1260-2019 FDA Class II initiated 20 Mar 2019
    • Terminated Z-1259-2019 FDA Class II initiated 20 Mar 2019
    • Terminated Z-1265-2019 FDA Class II initiated 20 Mar 2019

    During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy.

  • 3 recalls, same reason

    • Completed Z-0606-2019 FDA Class II initiated 24 May 2018
    • Completed Z-0607-2019 FDA Class II initiated 24 May 2018
    • Completed Z-0608-2019 FDA Class II initiated 24 May 2018

    When your system was installed, the Main disconnect switch, EPO button on the A1 panel, and Remote EPO button(s) (outside of the A1 panel) may not have been wired correctly which could result in these not shutting off all power to the entire system as intended, resulting in a potential electric hazard.

    • Terminated Z-2194-2017 FDA Class II initiated 19 May 2017

    It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed.

    • Terminated Z-0367-2014 FDA Class II initiated 25 Oct 2013

    GE Healthcare has recently become aware of a potential safety issue related to a SPECT scan procedure used for pulmonary imaging. Contact between the Detector (GE Healthcare Discovery NM/CT 670, and/or Optima NM/CT 640, and/or Discovery NM630, and/or Brivo NM 615 all configurations) and the Patient's elbow may occur during SPECT protocols using 450 angular steps in scenarios when a Patients a

    • Terminated Z-1792-2013 FDA Class I initiated 13 Jun 2013

    GE became aware of an incident at a VA Medical Center facility in the US in which a patient died due to injuries sustained while being scanned on an Infinia Hawkeye 4 Nuclear Medicine System. UPDATE: On July 03, 2013 GE notified hospitals that they are recalling several Nuclear Medicine Imaging Systems because serious injuries or deaths could occur due to the failure mode associated with this re

    • Terminated Z-0121-2013 FDA Class II initiated 12 Oct 2012

    GE Healthcare has recently become aware of a potential safety issue associated with the table pallet of your Discovery NM/CT 670 and/or Discovery NM630 system which may impact operation safety. At scan setup, during gantry rotation towards scanning position, a potential contact between the table-pallet-edge and the detector was identified. Such occurrence may damage the pallet front-edge and

    • Terminated Z-1110-2012 FDA Not yet classified initiated 11 Jan 2012

    GE Healthcare has recently become aware of a potential safety issue associated with the collimator cart and lead cover of your Discovery NM/CT 670 and/or Discovery NM 630 system that may impact operator safety. 1. The cart locking pin release and cart disengagement could result in the collimator falling down and could lead to operator or service personnel injury. 2. Another issue is that the

Timeline

24 dated events

  1. Recall initiated FDA recalls Z-2996-2020
  2. Recall initiated FDA recalls Z-2997-2020
  3. Recall initiated FDA recalls Z-0857-2021
  4. Recall initiated FDA recalls Z-1547-2021
  5. Recall initiated FDA recalls Z-1053-2023
  6. Recall initiated FDA recalls Z-0895-2025
  7. Recall initiated FDA recalls Z-0894-2025
  8. Recall initiated FDA recalls Z-0893-2025
  9. Recall initiated FDA recalls Z-0891-2025
  10. Registered EUDAMED B-00840682140836

14 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Nm/CT 870 Dr EUDAMED
Nmct GUDID
Generic name
Stationary gamma camera system
Model / reference
NM/CT 870 DR EUDAMED
H3100AP EUDAMED
H3100AR EUDAMED
H3906ED EUDAMED
H3906EM EUDAMED
H3906EN EUDAMED
H3906EP EUDAMED
870 DR GUDID
Primary DI / UDI-DI
00840682140836
Basic UDI-DI
B-00840682140836
510(k) Number
FDA product code
JAK, KPS
EMDN code
Z11020201 CT/gamma camera systems
GMDN term
Stationary gamma camera system
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1750, 892.1200
System or procedure pack
System which is a device in itself
EU registration type
Legacy device (under a directive)
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
NM/CT 870 DR
H3100AP, H3100AR, H3906ED, H3906EM, H3906EN, H3906EP
GUDID
870 DR
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under NUCLEAR MEDICINE INSTRUMENTS.

Other devices from GE Medical Systems Israel, Functional Imaging

See all devices from GE Medical Systems Israel, Functional Imaging →

Properties

  • Measuring function
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (19, all answered No)