Oec Fluorotrak 9800 Plus

by Ge Oec Medical Systems

510(k) K022069

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

18 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK022069 Date17 Sep 2002ClearedStatusActive

Recalls

18 recalls · FDA

    • Terminated Z-2629-2016 FDA Class II initiated 22 Jul 2016

    A firmware issue in the supplied LCD workstation monitor(s). Under some circumstances, the monitor(s) may appear dark with no video displayed.

    • Terminated Z-0195-2015 FDA Class II initiated 3 Oct 2014

    GE Healthcare initiated a field correction because prior revision of components were potentially installed on certain OEC 9800, FlexiView 8800, OEC MiniView 6800 and OEC UroView 2800 systems.

    • Terminated Z-2241-2012 FDA Class II initiated 26 Apr 2010 on shared 510(k) K022069

    GE OEC recalled certain 9800 Fluoroscope & 9900 Elite Models because the Snubber Board did not conform to the IEC 60601-1 standard for clearance and creepage of voltage isolation.

    • Terminated Z-2240-2012 FDA Class II initiated 6 Nov 2009 on shared 510(k) K022069

    GE OEC is recalling certain 9800 Image Intensified Flouroscopic x-ray systems due to customer complaint analysis showing that a replacement Hitachi 160 GB Hard Drive, when installed on certain models is susceptible of causing unanticipated system shut downs, no boots, data loss or data mix, or unexpected hard drive corruption.

    • Terminated Z-2262-2012 FDA Class II initiated 10 Oct 2008 on shared 510(k) K022069

    GE initiated a correction to the instructions/use due to the potential for erroneous auto injection of contrast dye.

    • Terminated Z-1705-2008 FDA Unclassified (pre-2012) initiated 15 Apr 2008 on shared 510(k) K022069

    Use of existing four-pedal footswitch on a different machine may cause various operational errors.

    • Terminated Z-2038-2012 FDA Class I initiated 22 Feb 2008 on shared 510(k) K022069

    Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. The vertical lift column power supply in the mainframe C-arm of the device is defective and subject to early life failure.

    • Terminated Z-2026-2012 FDA Class II initiated 19 Nov 2007 on shared 510(k) K022069

    Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. GE OEC recalled imaging devices OEC 9900, OEC 9800, and OEC 8800 as a result of an FDA inspection identifying that the vertical lift column power supply in the mainframe C-arm is defective and subject to early life failure.

  • 4 recalls, same reason

    • Terminated Z-0677-2007 FDA Unclassified (pre-2012) initiated 1 Mar 2007 on shared 510(k) K022069
    • Terminated Z-0680-2007 FDA Unclassified (pre-2012) initiated 1 Mar 2007 on shared 510(k) K022069
    • Terminated Z-0681-2007 FDA Unclassified (pre-2012) initiated 1 Mar 2007 on shared 510(k) K022069
    • Terminated Z-0682-2007 FDA Unclassified (pre-2012) initiated 1 Mar 2007 on shared 510(k) K022069

    During routine service, primary and/or secondary collimators may not have been properly reinstalled.

  • 4 recalls, same reason

    • Terminated Z-0558-2007 FDA Unclassified (pre-2012) initiated 9 Feb 2007 on shared 510(k) K022069
    • Terminated Z-0557-2007 FDA Unclassified (pre-2012) initiated 9 Feb 2007 on shared 510(k) K022069
    • Terminated Z-0556-2007 FDA Unclassified (pre-2012) initiated 9 Feb 2007 on shared 510(k) K022069
    • Terminated Z-0559-2007 FDA Unclassified (pre-2012) initiated 9 Feb 2007 on shared 510(k) K022069

    During routine service, a cover may have been installed without the required proper lead shielding.

    • Terminated Z-0709-06 FDA Unclassified (pre-2012) initiated 6 Feb 2006 on shared 510(k) K022069

    Small retaining pin may detach and fall into the surgical field during stereotactic surgery.

    • Terminated Z-0692-5 FDA Unclassified (pre-2012) initiated 13 Dec 2004 on shared 510(k) K022069

    Enhanced sterility testing revealed the sterilization efficacy of accessories ('Sensors') used with certain Navigation and Visualization systems may be compromised.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
OWB
Device Class
Class II
Regulation
21 CFR Part 892.1650
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Other devices from GE Oec Medical Systems, Inc

See all devices from GE Oec Medical Systems, Inc →