Oec Fluorotrak 9800 Plus
510(k) K022069
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK022069 | Date17 Sep 2002 | StatusActive |
Recalls
-
- Terminated Z-2629-2016
A firmware issue in the supplied LCD workstation monitor(s). Under some circumstances, the monitor(s) may appear dark with no video displayed.
-
- Terminated Z-0195-2015
GE Healthcare initiated a field correction because prior revision of components were potentially installed on certain OEC 9800, FlexiView 8800, OEC MiniView 6800 and OEC UroView 2800 systems.
-
- Terminated Z-2241-2012
GE OEC recalled certain 9800 Fluoroscope & 9900 Elite Models because the Snubber Board did not conform to the IEC 60601-1 standard for clearance and creepage of voltage isolation.
-
- Terminated Z-2240-2012
GE OEC is recalling certain 9800 Image Intensified Flouroscopic x-ray systems due to customer complaint analysis showing that a replacement Hitachi 160 GB Hard Drive, when installed on certain models is susceptible of causing unanticipated system shut downs, no boots, data loss or data mix, or unexpected hard drive corruption.
-
- Terminated Z-2262-2012
GE initiated a correction to the instructions/use due to the potential for erroneous auto injection of contrast dye.
-
- Terminated Z-1705-2008
Use of existing four-pedal footswitch on a different machine may cause various operational errors.
-
- Terminated Z-2038-2012
Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. The vertical lift column power supply in the mainframe C-arm of the device is defective and subject to early life failure.
-
- Terminated Z-2026-2012
Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. GE OEC recalled imaging devices OEC 9900, OEC 9800, and OEC 8800 as a result of an FDA inspection identifying that the vertical lift column power supply in the mainframe C-arm is defective and subject to early life failure.
-
- Terminated Z-0677-2007
- Terminated Z-0680-2007
- Terminated Z-0681-2007
- Terminated Z-0682-2007
During routine service, primary and/or secondary collimators may not have been properly reinstalled.
-
- Terminated Z-0558-2007
- Terminated Z-0557-2007
- Terminated Z-0556-2007
- Terminated Z-0559-2007
During routine service, a cover may have been installed without the required proper lead shielding.
-
- Terminated Z-0709-06
Small retaining pin may detach and fall into the surgical field during stereotactic surgery.
-
- Terminated Z-0692-5
Enhanced sterility testing revealed the sterilization efficacy of accessories ('Sensors') used with certain Navigation and Visualization systems may be compromised.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- OWB
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.1650
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent