Skip to content

Omnifit 2006-2856

by Howmedica Osteonics Corp.

Omnifit 2006-2856 is a constrained polyethylene acetabular liner (FDA Class III) made by Howmedica Osteonics Corp., cleared under FDA 510(k) K261624 on 10 Jul 2026 (4 earlier submissions) and listed in FDA GUDID since 24 Sep 2015 (UDI-DI 07613327021530), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK261624 Date10 Jul 2026DecidedStatusActive
United StatesGUDID listing Number07613327021530 UDI-DI Date24 Sep 2015ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
20 Degree Series I Insert
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K261624 decided 10 Jul 2026 Active· +4 more in the status table
  • FDA GUDID UDI-DI 07613327021530 listed 24 Sep 2015 Listed

Recalls

3 recalls · 3 ongoing · FDA

  • 3 recalls, same reason

    • Ongoing Z-3196-2026 FDA Class II initiated 30 Jul 2026
    • Ongoing Z-3199-2026 FDA Class II initiated 30 Jul 2026 on shared 510(k) K261624
    • Ongoing Z-3201-2026 FDA Class II initiated 30 Jul 2026 on shared 510(k) K261624

    Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

9 dated events

  1. Cleared FDA 510(k) K850352
  2. Cleared FDA 510(k) K890197
  3. Cleared FDA 510(k) K900438
  4. Listed FDA GUDID 07613327021530
  5. Cleared FDA 510(k) K243784
  6. Cleared FDA 510(k) K261624
  7. Recall initiated FDA recalls Z-3196-2026
  8. Recall initiated FDA recalls Z-3199-2026
  9. Recall initiated FDA recalls Z-3201-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Omnifit
Generic name
Constrained polyethylene acetabular liner
Model / Ref / Catalog
2006-2856
Primary DI / UDI-DI
07613327021530
FDA product code
JDL, JDI
GMDN term
Constrained polyethylene acetabular liner
Device class
Class III
Regulation number
888.3320, 888.3350
GUDID distribution status
In Commercial Distribution
Size
Lumen/Inner Diameter — 28.0 Millimeter

Similar devices in this category

Other devices filed under Constrained polyethylene acetabular liner.

Other devices from Howmedica Osteonics Corp.

See all devices from Howmedica Osteonics Corp. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
Other properties (10, all answered No)