Optima CT660
by GE Medical Systems, LLC 2 variants
510(k) K131576
Optima CT660 is a medical device (FDA Class II; FDA product code JAK, System, X-Ray, Tomography, Computed) made by GE Medical Systems, LLC, cleared under FDA 510(k) K131576 on 30 Aug 2013, active as of 22 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK131576 | Date30 Aug 2013 | StatusActive |
Official records
- FDA 510(k) database K131576
From the FDA record
- Received by the FDA
- 31 May 2013
- FDA decision
- 30 Aug 2013 (Substantially Equivalent)
- FDA review time
- 91 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-0608-2025
GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.
-
- Ongoing Z-1900-2021
Improperly loaded software options may result in additional X -ray radiation exposure to the patient.
-
- Terminated Z-2583-2018
- Terminated Z-2584-2018
Some CT and CT/PET systems recently installed with a GE supplied A! electrical panel may not be properly wired to the partial system UPS (Uninteruptible Power Supply).
-
- Terminated Z-2873-2018
- Terminated Z-2870-2018
GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to Service Engineers working inside the gantry.
-
- Terminated Z-2181-2017
- Terminated Z-2182-2017
It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed.
Timeline
- Cleared FDA 510(k) K131576
- Recall initiated FDA recalls Z-2181-2017
- Recall initiated FDA recalls Z-2182-2017
- Recall initiated FDA recalls Z-2873-2018
- Recall initiated FDA recalls Z-2870-2018
- Recall initiated FDA recalls Z-2583-2018
- Recall initiated FDA recalls Z-2584-2018
- Recall initiated FDA recalls Z-1900-2021
- Recall initiated FDA recalls Z-0608-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- JAK
- Device class
- Class II
- Regulation
- 21 CFR Part 892.1750
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent
Devices cleared under K131576
Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.
| UDI-DI | Size and differences | |||
|---|---|---|---|---|
| NA Console Generation Upgrade | ConsoleGenerationUpgrade / Console Generation Upgrade | 00195278882677 | — | On the market |
| Optima CT660 Cj2.5 Upgrade | CT660 Cj2.5 Upgrade | 00840682116510 | — | On the market |
| Revolution | EVO | 00840682109796 | — | On the market |
Similar devices
Other devices filed under FDA product code JAK (System, X-Ray, Tomography, Computed).
- SOMATOM RADIATION TREATMENT PLANNING (RTP) PACKAGE by SIEMENS MEDICAL SOLUTIONS USA, INC.
- SHIMADZU WHOLE BODY X-RAY COMPUTED TOMOGRAPHY SCANNER SCT-7000TS by Shimadzu Medical Systems
- PHILIPS TOMOSCAN SR 4000 by Philips Medical Systems North America, Inc.
- GE LIGHTSPEED ACT FP16 by GE MEDICAL SYSTEMS, INC.
- CSBP-001A BODY PERFUSION SYSTEM by Toshiba Medical Systems
- DENTASCAN by Mpdi, Inc.
- CT-GUIDE NEEDLE GUIDANCE SYSTEM by Activiews, Ltd.
- INSPACE 4D SOFTWARE PACKAGE WITH EXTENDED FUNCTIONALITY by Siemens Medi Cal Solutions, Inc.
- PHILIPS TOMOSCAN SR by Philips Medical Systems North America, Inc.
- XPEED COMPUTED TOMOGRAPHY X-RAY SYSTEM by Toshiba America Medical Systems, In.C