Skip to content

Oscar 2 99-0133-12

by SunTech Medical, Inc

Oscar 2 99-0133-12 is a blood pressure ambulatory recorder (FDA Class II; FDA product code DXN, System, Measurement, Blood-Pressure, Non-Invasive) made by SunTech Medical, Inc, cleared under FDA 510(k) K151520 on 19 Feb 2016 and listed in FDA GUDID since 10 Jun 2017 (UDI-DI 10840935107507), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

510(k) K151520

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10840935107507 UDI-DI Date10 Jun 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Abbreviated NumberK151520 Date19 Feb 2016DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K151520 decided 19 Feb 2016 Active
  • FDA GUDID UDI-DI 10840935107507 listed 10 Jun 2017 Listed

Recalls

2 recalls · FDA

    • Terminated Z-2429-2020 FDA Class II initiated 20 Apr 2020

    The device display, when activated, can show an incorrect decimal point when the blood pressure reading is a three-digit number and the unit of measure is set for mmHg.

    • Terminated Z-0810-2020 FDA Class II initiated 11 Dec 2019

    The Bravo Mini (Model 250D), Agilis Mini (Model 250D), and NBP One (Model 250D) are being recalled because of a user safety issue when rechargeable batteries are misused in the product.

Timeline

4 dated events

  1. Cleared FDA 510(k) K151520
  2. Listed FDA GUDID 10840935107507
  3. Recall initiated FDA recalls Z-0810-2020
  4. Recall initiated FDA recalls Z-2429-2020

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Oscar 2
Generic name
Blood pressure ambulatory recorder
Model / reference
99-0133-12
Primary DI / UDI-DI
10840935107507
510(k) Number
FDA product code
DXN
GMDN term
Blood pressure ambulatory recorder
Device class
Class II
Regulation number
870.1130
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Blood pressure ambulatory recorder.

Other devices from SunTech Medical, Inc

See all devices from SunTech Medical, Inc →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (12, all answered No)