Philips Laser System
Ref LAS-100
Philips Laser System (LAS-100) is an atherectomy excimer laser system (EU MDD Class IIb; FDA Class III; FDA product code LPC, Device, Angioplasty, Laser, Coronary) made by Spectranetics Corporation, registered in EUDAMED on 4 Feb 2025 (Basic UDI-DI B-00813132027452), approved under FDA PMA P910001 on 19 Feb 1993 and listed in FDA GUDID since 20 Sep 2021 (UDI-DI 00813132027452), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00813132027452 00813132027452 | Date4 Feb 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00813132027452 | Date20 Sep 2021 | StatusListed |
| United States | FDA PMAAPPR GUDID | NumberP910001 | Date19 Feb 1993 | StatusActive |
Official records
- EUDAMED public site B-00813132027452
- AccessGUDID record 00813132027452
- FDA PMA database P910001
From the FDA record
- Device description
- Excimer Laser System
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI B-00813132027452 registered 4 Feb 2025 Active
- FDA PMA P910001 decided 19 Feb 1993 Active
- FDA GUDID UDI-DI 00813132027452 listed 20 Sep 2021 Listed
Recalls
-
- Ongoing Z-0221-2023
Laser System may detect Error 106 or Error 108 System Failures that will cause the system to enter non-recoverable safe state. The user will not be able to proceed until the error is cleared. May result in initiation of treatment delay and/or treatment beyond initial scope and/or unable to treat patient.
-
- Ongoing Z-1351-2022
The LAS-100 Laser system may detect an inoperable hardware component during power up, which results in an error code and the system not being operable until code is cleared.
Timeline
- Approved FDA PMA P910001
- Listed FDA GUDID 00813132027452
- Recall initiated FDA recalls Z-1351-2022
- Recall initiated FDA recalls Z-0221-2023
- Registered EUDAMED B-00813132027452
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Atherectomy excimer laser system
- Model / Ref / Catalog
- LAS-100
- Primary DI / UDI-DI
- 00813132027452
- Basic UDI-DI
- B-00813132027452
- PMA number
- FDA product code
- LPC
- EMDN code
- Z12011001 Excimer surgical laser
- GMDN term
- Atherectomy excimer laser system
- Device class
- Class IIb EUDAMEDClass III GUDID
- System or procedure pack
- System which is a device in itself
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class III |
Manufacturer details
- EUDAMED SRN
- US-MF-000020669
- Authorised representative
- Spectranetics International B.V. NL-AR-000001484
Similar devices in this category
Other devices filed under LASER SURGERY INSTRUMENTS.
- TECHNOLAS TENEO 317 Model 2 w/ ANTERION 70010022TPV by Technolas Perfect Vision GmbH
- iRes AX002, AX003 by iVis Technologies S.r.l.
- Skin Laser Scanners 1 by BEIJING HONKON TECHNOLOGIES CO., LTD.
- Dermatological Carbon Dioxide Laser Systems 1 by BEIJING HONKON TECHNOLOGIES CO., LTD.
- Diode Laser Therapy Devices 8127 by Shanghai Apolo Medical Technology Co., Ltd
- MED-Fibers, Inc. MF-365/400-SBT by MED -FIBERS INC.
- Litho DK 30 PVMS00025 by Quanta System S.p.A.
- Diode Laser Therapy Devices 8172 by Shanghai Apolo Medical Technology Co., Ltd
- TruScan Pro TP0009 by Lightmed Corporation
- Vbeam Prima Basic Configuration 9914-00-9081 by Candela Corporation