Pipeline Fa-71375-25
by Micro Therapeutics, Inc. 3 variants
Pipeline Fa-71375-25 is a Class III device made by Micro Therapeutics, Inc., approved under FDA PMA P100018 on 6 Apr 2011 and listed in FDA GUDID since 6 Apr 2015 (UDI-DI 00847536008953), active as of 23 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
4 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00847536008953 | Date6 Apr 2015 | StatusListed |
| United States | FDA PMAAPPR | NumberP100018 | Date6 Apr 2011 | StatusActive |
Official records
- AccessGUDID record 00847536008953
- FDA PMA database P100018
Across registries
- FDA PMA P100018 decided 6 Apr 2011 Active
- FDA GUDID UDI-DI 00847536008953 listed 6 Apr 2015 Listed
Recalls
-
- Ongoing Z-1245-2025
- Ongoing Z-1246-2025
Use of embolization device with diameters greater-than-or-equal-to 4mm may lead to incomplete wall apposition and/or braid deformation (fish-mouthing/braid narrowing/braid collapse) noted during procedure and post-procedure, typically noted at 6-12 month imaging follow-up, potentially can lead to thrombosis and/or serious adverse events. Higher risk in females less-than-or-equal-to 45 years of age
-
- Ongoing Z-2403-2021
- Ongoing Z-2402-2021
Due to potential push wire fractures in the delivery system during use. The issue presents as a fracture in the spiral cut area of the Hypotube.
-
- Terminated Z-1527-2020
Embolization device delivery system may fracture at the distal section during device implantation. A weakened bond may result in unintended separation, where the distal portion of the device delivery system remains in the patient. If a Pipeline Flex embolization device has already been implanted successfully, there is no increased risk to patients due to this issue.
-
- Terminated Z-0309-2017
- Terminated Z-0308-2017
- Terminated Z-0307-2017
- Terminated Z-0310-2017
Delamination and detachment of the PTFE (polytetrafluoroethylene) coating material may lead to PTFE coating in the blood stream.
-
- Terminated Z-0120-2016
The firm is recalling Pipeline and Pipeline Flex Embolization Devices from U.S. since the devices were shipped with an EU version of the Instructions for Use.
-
- Terminated Z-1453-2014
Potential for the PTFE (polytetrafluoroethylene) coating to delaminate and detach from the delivery wire.
-
- Terminated Z-2045-2013
Covidien Neurovascular has initiated the recall of several lots of Pipeline Embolization Device (PED) because the Instructions For Use (IFU) do not include the following contraindication: Patients in whom a pre-existing stent is in place in the parent artery at the target aneurysm location. Additionally, the designation of aspirin and clopidogrel was missing from the following contraindication "
Timeline
- Recall initiated FDA recalls Z-0120-2016
- Recall initiated FDA recalls Z-0309-2017
- Recall initiated FDA recalls Z-0308-2017
- Recall initiated FDA recalls Z-0307-2017
- Recall initiated FDA recalls Z-0310-2017
- Recall initiated FDA recalls Z-1527-2020
- Recall initiated FDA recalls Z-2403-2021
- Recall initiated FDA recalls Z-2402-2021
- Recall initiated FDA recalls Z-1245-2025
- Recall initiated FDA recalls Z-1246-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Trade name
- Pipeline
- Generic name
- Bare-metal intracranial vascular stent
- Model / reference
- FA-71375-25
- Primary DI / UDI-DI
- 00847536008953
- PMA number
- FDA product code
- OUT
- GMDN term
- Bare-metal intracranial vascular stent
- Device class
- Class III
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
- Size
- Length — 25.0 MillimeterOuter Diameter — 3.75 Millimeter
Similar devices
Other devices filed under FDA product code OUT (Intracranial aneurysm flow diverter).