RayStation 8.0
by RaySearch Laboratories AB (PUBL)
Ref 8.0
RayStation 8.0 is a device classified as Class IIb in the EU and Class II in the US made by RaySearch Laboratories AB (PUBL), registered in EUDAMED on 27 Oct 2026 (Basic UDI-DI B-07350002010112), cleared under FDA 510(k) K180379 on 25 Apr 2018 and listed in FDA GUDID since 27 Jun 2018 (UDI-DI 07350002010112), active as of 7 Nov 2026. 7 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
3 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-07350002010112 07350002010112 | Date27 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number07350002010112 | Date27 Jun 2018 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK180379 | Date25 Apr 2018 | StatusActive |
Official records
- EUDAMED public site B-07350002010112
- AccessGUDID record 07350002010112
- FDA 510(k) database K180379
Across registries
- EUDAMED Basic UDI-DI B-07350002010112 registered 27 Oct 2026 Active
- FDA 510(k) K180379 decided 25 Apr 2018 Active
- FDA GUDID UDI-DI 07350002010112 listed 27 Jun 2018 Listed
Recalls
-
- Ongoing Z-2487-2025
DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique.
-
- Ongoing Z-1185-2025
Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
- Ongoing Z-1742-2024
Potential for reported SSD to be too high.
-
- Terminated Z-0679-2019
Isocenter shifts when using dose tracking in RayStation 3.5, RayStation 4.0, RayStation 4.5, RayStation 4.7, RayStation 5, RayStation 6, RayStation 7 and RayStation 8A. In these versions, isocenter shifts in dose tracking are incorrectly interpreted according to the DICOM patient coordinate system.
-
- Terminated Z-0294-2019
Robust optimization for plans using beam set + background dose is not supported in RayStation 4.5, RayStation 4.7, RayStation 5, RayStation 6 and RayStation 7.
-
- Terminated Z-2497-2018
If the beam model has a highly asymmetric primary source, it is not correctly taken into account in the calculation of DMLC fields when the collimator is rotated. This could lead to potentially significant overdosage at delivery. The user must be aware of the issue to avoid incorrect dose calculations during treatment planning.
-
- Terminated Z-2554-2018
The firm has learned that some RayStation/RayPlan users have commissioned machines with erroneous Beam profile correction parameters. These parameters affect the dose calculated in corners of large or off-axis fields. This effect cannot be seen in the Beam Commissioning module and dose in large or off-axis fields needs to be validated using the Beam 3D Modeling module in RayPhysics/RayPlan Physics. The user must be aware to avoid incorrect dose calculations during treatment planning.
Timeline
- Cleared FDA 510(k) K180379
- Recall initiated FDA recalls Z-2554-2018
- Listed FDA GUDID 07350002010112
- Recall initiated FDA recalls Z-2497-2018
- Recall initiated FDA recalls Z-0294-2019
- Recall initiated FDA recalls Z-0679-2019
- Recall initiated FDA recalls Z-1742-2024
- Recall initiated FDA recalls Z-1185-2025
- Recall initiated FDA recalls Z-2487-2025
- Registered EUDAMED B-07350002010112
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- RayStation 8.0 EUDAMEDRayStation GUDID
- Generic name
- Radiation therapy software
- Model / reference
- 8.0
- Primary DI / UDI-DI
- 07350002010112
- Basic UDI-DI
- B-07350002010112
- 510(k) Number
- FDA product code
- MUJ
- EMDN code
- Z11019082 Various radiotherapy and radiosurgery instruments - software accessories
- GMDN term
- Radiation therapy software
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.5050
- System or procedure pack
- System which is a device in itself
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Ireland
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under VARIOUS RADIOTHERAPY AND RADIOSURGERY INSTRUMENTS.
- Standard Imaging MAX SD 90030 by STANDARD IMAGING INC.
- Standard Imaging SuperMAX Electrometer 90018 by STANDARD IMAGING INC.
- Proton Therapy Combined System IBA-PTC-00 by Ion Beam Applications S.A.
- Xstrahl 150 X-Ray System Floor by Xstrahl, Ltd.
- Orfit Industries 32392 by Orfit Industries NV
- Calibration Cube and Levelling Plate Calibration Cube Mk2 by Vision RT Ltd.
- DDS/GAN DDS/GAN 005 by FONDAZIONE CENTRO NAZIONALE DI ADROTERAPIA ONCOLOGICA
- Real-Time Coach Mk2 5056190500788 by Vision RT Ltd.
- Orfit Industries 32405/10 by Orfit Industries NV
- Xstrahl 200 X-Ray System - Floor by Xstrahl, Ltd.