RayStation 7
by RaySearch Laboratories AB (PUBL)
510(k) K180379
RayStation 7 is a medical device (FDA Class II; FDA product code MUJ, System, Planning, Radiation Therapy Treatment) made by RaySearch Laboratories AB (PUBL), cleared under FDA 510(k) K180379 on 25 Apr 2018, active as of 22 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
3 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK180379 | Date25 Apr 2018 | StatusActive |
Official records
- FDA 510(k) database K180379
From the FDA record
- Received by the FDA
- 12 Feb 2018
- FDA decision
- 25 Apr 2018 (Substantially Equivalent)
- FDA review time
- 72 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-2487-2025
DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray's iDMS, are not guaranteed to be unique.
-
- Ongoing Z-1185-2025
Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
- Ongoing Z-1742-2024
Potential for reported SSD to be too high.
-
- Terminated Z-0679-2019
Isocenter shifts when using dose tracking in RayStation 3.5, RayStation 4.0, RayStation 4.5, RayStation 4.7, RayStation 5, RayStation 6, RayStation 7 and RayStation 8A. In these versions, isocenter shifts in dose tracking are incorrectly interpreted according to the DICOM patient coordinate system.
-
- Terminated Z-0294-2019
Robust optimization for plans using beam set + background dose is not supported in RayStation 4.5, RayStation 4.7, RayStation 5, RayStation 6 and RayStation 7.
-
- Terminated Z-2497-2018
If the beam model has a highly asymmetric primary source, it is not correctly taken into account in the calculation of DMLC fields when the collimator is rotated. This could lead to potentially significant overdosage at delivery. The user must be aware of the issue to avoid incorrect dose calculations during treatment planning.
-
- Terminated Z-2554-2018
The firm has learned that some RayStation/RayPlan users have commissioned machines with erroneous Beam profile correction parameters. These parameters affect the dose calculated in corners of large or off-axis fields. This effect cannot be seen in the Beam Commissioning module and dose in large or off-axis fields needs to be validated using the Beam 3D Modeling module in RayPhysics/RayPlan Physics. The user must be aware to avoid incorrect dose calculations during treatment planning.
Timeline
- Cleared FDA 510(k) K180379
- Recall initiated FDA recalls Z-2554-2018
- Recall initiated FDA recalls Z-2497-2018
- Recall initiated FDA recalls Z-0294-2019
- Recall initiated FDA recalls Z-0679-2019
- Recall initiated FDA recalls Z-1742-2024
- Recall initiated FDA recalls Z-1185-2025
- Recall initiated FDA recalls Z-2487-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- MUJ
- Device class
- Class II
- Regulation
- 21 CFR Part 892.5050
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent
Devices cleared under K180379
Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.
| UDI-DI | Size and differences | |||
|---|---|---|---|---|
| RayStation 7 | 7 | 07350002010068 | — | On the market |
| RayStation 8.0 | 8.0 | 07350002010112 | — | On the market |
Similar devices
Other devices filed under FDA product code MUJ (System, Planning, Radiation Therapy Treatment).
- RadCalc Software by LifeLine Software
- syngo.via RT Image Suite VC10 by Varian Medical Systems, Inc.
- IPLAN RT by Brainlab AG
- PRECISEPLAN 2.0 by Precision Therapy Intl., Inc.
- ODYSSEY by Permedics, Inc.
- RadOncAI by Informai
- EVTOOL MODEL # V. 1.0 by 3D Line USA, Inc.
- Monaco RTP System by Elekta Inc.
- FLEXIPLAN BRACHYTHERAPY TREATMENT PLANNING SYSTEM by Isodose Control B.V.
- ClearCalc Version 2.8 by Radformation, Inc.