Raystation

by Raysearch Laboratories AB 3 variants

510(k) K141860

Raystation is a medical device (FDA Class II; FDA product code MUJ, System, Planning, Radiation Therapy Treatment) made by Raysearch Laboratories AB, cleared under FDA 510(k) K141860 on 23 Oct 2014, active as of 22 Oct 2026. 5 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK141860 Date23 Oct 2014ClearedStatusActive

Official records

From the FDA record

Received by the FDA
10 Jul 2014
FDA decision
23 Oct 2014 (Substantially Equivalent)
FDA review time
105 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K141860 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

5 recalls · 1 ongoing · FDA

    • Ongoing Z-1195-2025 FDA Class II initiated 16 Jan 2025

    Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.

    • Terminated Z-1712-2016 FDA Class II initiated 10 Feb 2016

    A software issue with editing tools that use the left mouse button held down, for drawing in and interacting with the patient views and beams eye views. The views can become unsynchronized with the stored data if simultaneously right clicking, pressing Ctrl-S or Ctrl-Z while the left mouse button is held down. This bug does not affect dose computations, which are based on the stored system state.

    • Terminated Z-2785-2015 FDA Class II initiated 29 May 2015

    An error caused by a floating point precision problem tends to cause a problem with the display of isodose lines for dose and dose difference and color tables for dose, dose difference and PET images

    • Terminated Z-2457-2015 FDA Class II initiated 27 May 2015

    Issue with the algorithm for ROI contraction in RayStation 4.7 when non-uniform contraction distances are used. The ROI contraction tool uses six distances as input: right/left, inferior/superior and posterior/anterior. These contraction distances are, in error, pairwise reversed, i.e. right is interpreted as left, inferior is interpreted as superior, and posterior is interpreted as anterior.

    • Terminated Z-1310-2015 FDA Class II initiated 4 Mar 2015

    An issue with photon dose calculation for DMLC (Dynamic MLC) plans for machines where the MLC is positioned above the jaws, e.g. some Elekta linacs. The magnitude of the error depends on the beam model output factor corrections and on the individual DMLC plan characteristics.

Timeline

6 dated events

  1. Cleared FDA 510(k) K141860
  2. Recall initiated FDA recalls Z-1310-2015
  3. Recall initiated FDA recalls Z-2457-2015
  4. Recall initiated FDA recalls Z-2785-2015
  5. Recall initiated FDA recalls Z-1712-2016
  6. Recall initiated FDA recalls Z-1195-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
MUJ
Device class
Class II
Regulation
21 CFR Part 892.5050
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code MUJ (System, Planning, Radiation Therapy Treatment).

Other devices from Raysearch Laboratories AB

  • Raystation Version 1.0

    Class II
  • Raystation

    Class II
  • Rayautoplan 1.0

    Class II
  • Raydose

    Class II

See all devices from Raysearch Laboratories AB →