Raystation
by Raysearch Laboratories AB 3 variants
510(k) K141860
Raystation is a medical device (FDA Class II; FDA product code MUJ, System, Planning, Radiation Therapy Treatment) made by Raysearch Laboratories AB, cleared under FDA 510(k) K141860 on 23 Oct 2014, active as of 22 Oct 2026. 5 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK141860 | Date23 Oct 2014 | StatusActive |
Official records
- FDA 510(k) database K141860
From the FDA record
- Received by the FDA
- 10 Jul 2014
- FDA decision
- 23 Oct 2014 (Substantially Equivalent)
- FDA review time
- 105 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-1195-2025
Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in RayStation version 4.5 to 2024B including some service packs.
-
- Terminated Z-1712-2016
A software issue with editing tools that use the left mouse button held down, for drawing in and interacting with the patient views and beams eye views. The views can become unsynchronized with the stored data if simultaneously right clicking, pressing Ctrl-S or Ctrl-Z while the left mouse button is held down. This bug does not affect dose computations, which are based on the stored system state.
-
- Terminated Z-2785-2015
An error caused by a floating point precision problem tends to cause a problem with the display of isodose lines for dose and dose difference and color tables for dose, dose difference and PET images
-
- Terminated Z-2457-2015
Issue with the algorithm for ROI contraction in RayStation 4.7 when non-uniform contraction distances are used. The ROI contraction tool uses six distances as input: right/left, inferior/superior and posterior/anterior. These contraction distances are, in error, pairwise reversed, i.e. right is interpreted as left, inferior is interpreted as superior, and posterior is interpreted as anterior.
-
- Terminated Z-1310-2015
An issue with photon dose calculation for DMLC (Dynamic MLC) plans for machines where the MLC is positioned above the jaws, e.g. some Elekta linacs. The magnitude of the error depends on the beam model output factor corrections and on the individual DMLC plan characteristics.
Timeline
- Cleared FDA 510(k) K141860
- Recall initiated FDA recalls Z-1310-2015
- Recall initiated FDA recalls Z-2457-2015
- Recall initiated FDA recalls Z-2785-2015
- Recall initiated FDA recalls Z-1712-2016
- Recall initiated FDA recalls Z-1195-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- MUJ
- Device class
- Class II
- Regulation
- 21 CFR Part 892.5050
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent
Similar devices
Other devices filed under FDA product code MUJ (System, Planning, Radiation Therapy Treatment).
- Multimodality Simulation Workspace (MM Sim)1.0 728349 by Philips Medical Systems Nederland B.V.
- MRI Planner 3.0 M7104RT by GE Medical Systems, L.L.C.
- RT Elements, Cranial SRS, Spine SRS, Multiple Brain Mets SRS, RT QA, Adaptive Hybrid Surgery Analysis, Dose Review by Brainlab AG
- syngo.via RT Image Suite by SIEMENS MEDICAL SOLUTIONS USA, INC.
- Simuplan Treatment Planning System, Model V. 7.5 by Simuplan S.L.
- RayCare 2.3 by RaySearch Laboratories AB (PUBL)
- RayStation 10.1 by RaySearch Laboratories AB (PUBL)
- CYBERNIFE STEREOTACTIC RADIOSURGERY SYSTEM by Accuray, Inc.
- RADIONICS XKNIFE HDRT SYSTEM by Integra Radionics, Inc.
- Virtual Cone (1.0) by Varian Medical Systems, Inc.