RestoreSensor™SureScan® 97714
Ref 97714
Active
Valid until
Not listed
FDA recalls
4 ongoingDocuments
None linked in EUDAMED
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/AIMDD EUDAMED | NumberB-00763000100254 | Date28 Aug 2026 | StatusActive |
| European Union | CE/MDD EUDAMED | NumberB-00763000100254 | Date28 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00763000100254 | Date23 Sep 2014 | StatusListed |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-0372-2025
The Wireless Rechargers in the kits may be unable to enter a recharging session upon first use.
-
- Ongoing Z-1691-2024
inability to reprogram one device
-
- Ongoing Z-0780-2024
Medtronic has discovered an instance in which the Intellis A710 Clinician Programmer Application (CP App) could no longer establish a session with the Implantable Neurostimulator (INS) which resulted in the inability for the clinician to adjust stimulation parameters. In the event of this issue, the patient may receive inadequate or excessive therapy and experience non-optimal pain relief.
-
- Ongoing Z-2159-2021
Specific PINs of the Vectris SureScan MRI lead kits contain the incorrect lead electrode spacing information printed on the shelf box and the sterile pack labeling.
-
- Terminated Z-1926-2016
Loss of therapy during recharging of device. Reportedly, a charging session was terminated prior to obtaining recharge threshold voltage of 3.615, which triggered rapid battery depletion state. As a result, the device depleted to 1.925 volts in one to two days rather than the typical 30 days. Insufficient coupling between recharger and device during recharge session was found to be key factor.
-
- Terminated Z-1147-2015
Current labeling indicates that cycling improves device longevity in every programming scenario. However, enabling cycling at certain parameter settings may decrease the device battery longevity. With cycling enabled, longevity estimate displayed on the Model 8840Programmer may be inaccurate.
-
- Terminated Z-1524-2014
Medtronic neurostimulators (used with pain and deep brain stimulation therapy) have a cycling feature that, when enabled, allows stimulation output to be toggled on and off based on the programmed settings. The use of this feature is determined by the physician and set using the clinician programmer. Current labeling indicates the use of cycling improves device longevity and recharge interval
-
- Terminated Z-0278-2014
Medtronic notified customers regarding Loss of Stimulation of specific Implantable Neuro-Stimulators under the following specific conditions: Switching between groups with Multiple programs or creating program groups. Therapy can be restored with the Physician Recharge mode (RPM) of the Implantable Neurostimulator Recharger (INSR).
-
- Terminated Z-1536-06
Model 3777 Standard Octad Lead (Lot V009545) and Model 3778 Compact Octad Lead (Lot V009546) were mispackaged. The result of this error is that lead kits labeled 3777 lot V009545 may contain a 3778 compact-spaced lead, while those labeled 3778 lot V009546 may contain a 3777 standard-spaced lead. The result of this error is an overall increase or decrease of 14 mm in the electrode coverage.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- RestoreSensor® SureScan® EUDAMEDRestoreSensor™ SureScan™ EUDAMEDRestoreSensor™SureScan® GUDID
- Generic Name
- Spinal cord/peripheral nerve implantable analgesic electrical stimulation system pulse generator, implantable
- Device Name
- Implantable Neurostimulator
- Model / Reference
- 97714
- Primary DI / UDI-DI
- 00763000100254 EUDAMED00763000270124 EUDAMED00643169613690 EUDAMED00643169613676 EUDAMED00643169613683 EUDAMED00763000100247 EUDAMED00763000270131 EUDAMED00643169109483 GUDID
- Basic UDI-DI
- B-00763000100254, B-00763000270124, B-00643169613690, B-00643169613676, B-00643169613683, B-00763000100247, B-00763000270131
- PMA Number
- FDA Product Code
- LGW, QRB
- EMDN Code
- J02020201 Fully implantable spinal neurostimulators, rechargeable
- GMDN Term
- Spinal cord/peripheral nerve implantable analgesic electrical stimulation system pulse generator, implantable
- Device Class
- Class AIMDD EUDAMEDClass III GUDID
- EU market of registration
- Netherlands
- GUDID distribution status
- Not in Commercial Distribution
- MRI Safety
- MR Conditional
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Primary DI / UDI-DI | 00763000100254 00763000270124 00643169613690 00643169613676 00643169613683 00763000100247 00763000270131 | 00643169109483 |
| Device Class | Class AIMDD | Class III |
Other devices from Medtronic, Inc.
Properties
Other properties (18)
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Lot / Batch Number: No
- Expiration Date: No
- Manufacturing Date: No