Revolution Frontier ES
by GE Hangwei Medical Systems Co., Ltd.
Ref Revolution Frontier ES
Revolution Frontier ES is a device classified as Class IIb in the EU and Class II in the US made by GE Hangwei Medical Systems Co., Ltd., registered in EUDAMED on 27 Jan 2022 (Basic UDI-DI 8406821BUG00202GS), cleared under FDA 510(k) K120833 on 12 Jun 2012 and listed in FDA GUDID since 16 Aug 2022 (UDI-DI 00195278362247), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number00195278362247 | Date16 Aug 2022 | StatusListed |
| European Union | CE/MDR EUDAMED | Number8406821BUG00202GS 00195278362247 | Date27 Jan 2022 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK120833 | Date12 Jun 2012 | StatusActive |
Official records
- EUDAMED public site 8406821BUG00202GS
- AccessGUDID record 00195278362247
- FDA 510(k) database K120833
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00202GS registered 27 Jan 2022 Active
- FDA 510(k) K120833 decided 12 Jun 2012 Active
- FDA GUDID UDI-DI 00195278362247 listed 16 Aug 2022 Listed
Recalls
-
- Ongoing Z-0609-2025
GE HealthCare has become aware of a potential issue on certain Discovery, Optima, Revolution series CT systems, and certain operator console upgrades that can result in rotated CT images. Particularly with helical, cine, and cardiac (if applicable) scan modes, after the first image of an exam, each subsequent image can be rotated by an increasing amount. The amount of progressive image rotation is dependent on the gantry speed and the duration of the scan. The final image in the exam can be rotated up to a maximum of ~56 degrees. The entire anatomy rotates as a whole by equal degrees, without distortion, and the anatomical positioning and z-axis of the images remains correct. Small degrees of image rotation might not be noticed. If image rotation is noticed and necessitates a rescan of the patient, the same image rotation will reoccur.
Timeline
- Cleared FDA 510(k) K120833
- Registered EUDAMED 8406821BUG00202GS
- Listed FDA GUDID 00195278362247
- Recall initiated FDA recalls Z-0609-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Revolution Frontier ES EUDAMEDRevolution GUDID
- Generic name
- Full-body CT system
- Device name
- Revolution Frontier Gen 3_HD Refresh Package
- Model / reference
- Revolution Frontier ES EUDAMEDFrontier ES GUDID
- Primary DI / UDI-DI
- 00195278362247
- Basic UDI-DI
- 8406821BUG00202GS
- 510(k) Number
- FDA product code
- JAK
- EMDN code
- Z11030605 Computed tomographs - 64 layers or more but less than 128 layers
- GMDN term
- Full-body CT system
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1750
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | Revolution Frontier ES | Frontier ES |
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- CN-MF-000009292
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under COMPUTED TOMOGRAPHS - 64 LAYERS OR MORE BUT LESS THAN 128 LAYERS.
- NeuViz 64 In none by Neusoft Medical Systems Co., Ltd.
- Computed Tomography X-ray System 88000817 by Shanghai United Imaging Healthcare Co., Ltd.
- Philips CT 3500 by Philips Healthcare (Suzhou) Co., Ltd.
- IQon Spectral CT 728332 by Philips Medical Systems Nederland B.V.
- CT Areta RT 728382 by Philips Healthcare (Suzhou) Co., Ltd.
- X-ray equipment for computed tomography 3001 by KuanTeng (Beijing) Medical Technology Co., Ltd
- X-ray computed Tomography System ANATOM 64 Clarity by Shenzhen Anke High-Tech Co., Ltd.