← Back to catalogue

Saccadometer

FDA UDI

Class II (US FDA UDI)

by Ober Consulting Sp. Z.O.O.

Identity

Trade Name
SACCADOMETER FDA UDI
Generic Name
Eye movement analysis system FDA UDI
Device Name
The Saccadometer Plus system measures eye movements in horizontal axis with temporal 1kHz and spatial resolution < 5 arc min. The system incorporates a built in visual target presentation using miniature laser projectors mounted on the sensor forehead plate. Saccadometer Plus is equipped with three red laser projectors with 10º separation, and 6 experiments are included in embedded software. The information about the eye movement is stored in a small, self-contained control unit, and can be downloaded for computer analysis at a later stage. Information about eye movement is acquired by analyzing the infrared light reflected from eye orbit. The left and right eye orbit are illuminated by two infrared LEDs, providing eye surface irradiance below 1mW/cm 2 (operating condition). Due to the conjugacy and synchronicity of the saccadic eye movements, the rotation of left and right eyes, can be added and averaged. The inner canthi of the left and right eyes are illuminated with the low intensity IR. The difference between the amounts of IR reflected back from the eye surfaces toward the photodetecting circuitry, carries the information about the eye position changes. Two eye landmarks are taking part in generation of the eye movement signal: the corneal bulge and the limbus (the border between darker iris and white sclera). Main contributor to the eye movement signal is the corneal bulge. Being the relative eye position measurement system, it requires to define the initial eye position. It means that at the beginning of every measurement, a steady eye fixation point needs to be provided. In Saccadometer the central fixation target serves this purpose. FDA UDI
Model / Reference
PLUS FDA UDI
Description
The Saccadometer Plus system measures eye movements in horizontal axis with temporal 1kHz and spatial resolution < 5 arc min. The system incorporates a built in visual target presentation using miniature laser projectors mounted on the sensor forehead plate. Saccadometer Plus is equipped with three red laser projectors with 10º separation, and 6 experiments are included in embedded software. The information about the eye movement is stored in a small, self-contained control unit, and can be downloaded for computer analysis at a later stage. Information about eye movement is acquired by analyzing the infrared light reflected from eye orbit. The left and right eye orbit are illuminated by two infrared LEDs, providing eye surface irradiance below 1mW/cm 2 (operating condition). Due to the conjugacy and synchronicity of the saccadic eye movements, the rotation of left and right eyes, can be added and averaged. The inner canthi of the left and right eyes are illuminated with the low intensity IR. The difference between the amounts of IR reflected back from the eye surfaces toward the photodetecting circuitry, carries the information about the eye position changes. Two eye landmarks are taking part in generation of the eye movement signal: the corneal bulge and the limbus (the border between darker iris and white sclera). Main contributor to the eye movement signal is the corneal bulge. Being the relative eye position measurement system, it requires to define the initial eye position. It means that at the beginning of every measurement, a steady eye fixation point needs to be provided. In Saccadometer the central fixation target serves this purpose. FDA UDI

Identifiers

Primary DI / UDI-DI
05906874392010 FDA UDI
510(k) Number
K152890 FDA UDI
FDA Product Code
HLL FDA UDI
GMDN Term
Eye movement analysis system FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
886.1510 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

No

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

No

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

Yes

FDA UDI

Category: Eye movement analysis system

Saccadometer by Ober Consulting Sp. Z.O.O. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Eye movement analysis system.

Cleared under the same submission

K152890 also covers:

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI 6608604e-774c-49ac-8c9a-4fa7d55887ec 36 fields · synced May 30, 2026