Identity
- Trade Name
- SACCADOMETER FDA UDI
- Generic Name
- Eye movement analysis system FDA UDI
- Device Name
- The Saccadometer Plus system measures eye movements in horizontal axis with temporal 1kHz and spatial resolution < 5 arc min. The system incorporates a built in visual target presentation using miniature laser projectors mounted on the sensor forehead plate. Saccadometer Plus is equipped with three red laser projectors with 10º separation, and 6 experiments are included in embedded software. The information about the eye movement is stored in a small, self-contained control unit, and can be downloaded for computer analysis at a later stage. Information about eye movement is acquired by analyzing the infrared light reflected from eye orbit. The left and right eye orbit are illuminated by two infrared LEDs, providing eye surface irradiance below 1mW/cm 2 (operating condition). Due to the conjugacy and synchronicity of the saccadic eye movements, the rotation of left and right eyes, can be added and averaged. The inner canthi of the left and right eyes are illuminated with the low intensity IR. The difference between the amounts of IR reflected back from the eye surfaces toward the photodetecting circuitry, carries the information about the eye position changes. Two eye landmarks are taking part in generation of the eye movement signal: the corneal bulge and the limbus (the border between darker iris and white sclera). Main contributor to the eye movement signal is the corneal bulge. Being the relative eye position measurement system, it requires to define the initial eye position. It means that at the beginning of every measurement, a steady eye fixation point needs to be provided. In Saccadometer the central fixation target serves this purpose. FDA UDI
- Model / Reference
- PLUS FDA UDI
- Description
- The Saccadometer Plus system measures eye movements in horizontal axis with temporal 1kHz and spatial resolution < 5 arc min. The system incorporates a built in visual target presentation using miniature laser projectors mounted on the sensor forehead plate. Saccadometer Plus is equipped with three red laser projectors with 10º separation, and 6 experiments are included in embedded software. The information about the eye movement is stored in a small, self-contained control unit, and can be downloaded for computer analysis at a later stage. Information about eye movement is acquired by analyzing the infrared light reflected from eye orbit. The left and right eye orbit are illuminated by two infrared LEDs, providing eye surface irradiance below 1mW/cm 2 (operating condition). Due to the conjugacy and synchronicity of the saccadic eye movements, the rotation of left and right eyes, can be added and averaged. The inner canthi of the left and right eyes are illuminated with the low intensity IR. The difference between the amounts of IR reflected back from the eye surfaces toward the photodetecting circuitry, carries the information about the eye position changes. Two eye landmarks are taking part in generation of the eye movement signal: the corneal bulge and the limbus (the border between darker iris and white sclera). Main contributor to the eye movement signal is the corneal bulge. Being the relative eye position measurement system, it requires to define the initial eye position. It means that at the beginning of every measurement, a steady eye fixation point needs to be provided. In Saccadometer the central fixation target serves this purpose. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 05906874392010 FDA UDI
- 510(k) Number
- K152890 FDA UDI
- FDA Product Code
- HLL FDA UDI
- GMDN Term
- Eye movement analysis system FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 886.1510 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
Category: Eye movement analysis system
Saccadometer by Ober Consulting Sp. Z.O.O. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Eye movement analysis system.
- MedTrakVNG Interface Controller — MEDTRAK VNG, INC · Class II
- Eye Tracker Camera — Nordicneurolab · Class II
- Interacoustics — Interacoustics A/S · Class II
- MedTrakVNG MobiTrak System — MEDTRAK VNG, INC · Class II
- MedTrakVNG Goggle — MEDTRAK VNG, INC · Class II
- MobiTrak Software v3.00 — MEDTRAK VNG, INC · Class II
- MedTrakVNG Footswitch — MEDTRAK VNG, INC · Class II
- MobiTrakVNG Receiver — MEDTRAK VNG, INC · Class II
Cleared under the same submission
K152890 also covers:
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Ober Consulting Sp. Z.O.O.
Sources (1)
- FDA UDI 6608604e-774c-49ac-8c9a-4fa7d55887ec 36 fields · synced May 30, 2026