SmartDrive® MX2
SmartDrive MX2, a wheelchair electric-motor-driven propulsion system (FDA Class II; FDA product code ITI, Wheelchair, Powered) made by Max Mobility, LLC, was cleared under FDA 510(k) K151199 on 30 Jul 2015 and listed in FDA GUDID on 23 Sep 2016 (UDI-DI 00861896000303); the registry lists it as not in commercial distribution (GUDID) as of 22 Oct 2026. FDA recalls on record: 7.
Active
Valid until
No expiry
FDA recalls
7 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00861896000303 | Date23 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK151199 | Date30 Jul 2015 | StatusActive |
Official records
- AccessGUDID record 00861896000303
- FDA 510(k) database K151199
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K151199 decided 30 Jul 2015 Active
- FDA GUDID UDI-DI 00861896000303 listed 23 Sep 2016 Listed
Recalls
-
- Ongoing Z-2538-2025
- Ongoing Z-2539-2025
- Ongoing Z-2540-2025
Due to a faulty electrical connection between the speed control Dial and the wheelchair motor, their is a potential for lost of control of the device potentially resulting in minor or major injuries.
-
- Ongoing Z-1116-2025
- Ongoing Z-1117-2025
Due to faulty circuit board in speed control remote use in conjunction with a wheelchair power assist, their is a potential for lost of control of device potentially resulting in minor and major injuries.
-
- Ongoing Z-2004-2023
- Ongoing Z-2005-2023
When multiple processes are running on the watch's Central Processing Unit (CPU), the application may fail unexpectedly. If this happens, the motor on the power assist device continues to run and the user may not be able to stop the device using tap gestures.
Timeline
- Cleared FDA 510(k) K151199
- Listed FDA GUDID 00861896000303
- Recall initiated FDA recalls Z-2004-2023
- Recall initiated FDA recalls Z-2005-2023
- Recall initiated FDA recalls Z-1116-2025
- Recall initiated FDA recalls Z-1117-2025
- Recall initiated FDA recalls Z-2538-2025
- Recall initiated FDA recalls Z-2539-2025
- Recall initiated FDA recalls Z-2540-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- SmartDrive®
- Generic name
- Wheelchair electric-motor-driven propulsion system
- Model / reference
- MX2
- Primary DI / UDI-DI
- 00861896000303
- 510(k) Number
- FDA product code
- ITI
- GMDN term
- Wheelchair electric-motor-driven propulsion system
- Device class
- Class II
- Regulation number
- 890.3860
- GUDID distribution status
- Not in Commercial Distribution
Similar devices
Other devices filed under FDA product code ITI (Wheelchair, Powered).
- Haida HD21 by Jiangyin East China Medical Technology Co., Ltd.
- Fortress Commuter FT (Folding Transport) by Fortress, Inc.
- Electric wheelchair (S7204/S7205) by Dongguan Prestige Sporting Goods Co., Ltd.
- Power Wheelchair (ZS-EW8026) by Ningbo Zhishan Medical Technology Co., Ltd
- Heartway Electrically Powered Wheelchairs by HEARTWAY MEDICAL PRODUCTS CO., LTD.
- Powered Wheelchair (PL001-9001) by Suzhou KD Intelligent Device Co., Ltd.
- Relay Power Wheelchair by Dalton Instrument Corp.
- M71 Power Wheelchair by Invacare Corp.
- Lerado Power Wheelchair PB by Lerado China Limited
- Quickie P90 Series by Quickie Designs, Inc.