SMR Shoulder Glenoid Impactor
Part of a family of 25 devices: see the family page
Ref 9013.75.110Model 80333902A064C2, SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor
SMR Shoulder Glenoid Impactor (9013.75.110) is an orthopaedic implant impactor (EU MDD Class IIa; EU MDD Class I; FDA Class II) made by Limacorporate, registered in EUDAMED on 29 Oct 2026 (Basic UDI-DI 80333902A064C2), cleared under FDA 510(k) K100858 on 10 Dec 2010 and listed in FDA GUDID since 6 Apr 2016 (UDI-DI 08033390046961), active as of 7 Nov 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | Number80333902A064C2 08033390046961 | Date29 Oct 2026 | StatusActive |
| European Union | CE/MDR EUDAMED | Number80333902A064C2 08033390046961 | Date29 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number08033390046961 | Date6 Apr 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK100858 | Date10 Dec 2010 | StatusActive |
Official records
- EUDAMED public site 80333902A064C2
- AccessGUDID record 08033390046961
- FDA 510(k) database K100858
From the FDA record
- Device description
- SMALL/STD/LARGE MB Glenoid Impactor
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 80333902A064C2 registered 29 Oct 2026 Active
- FDA 510(k) K100858 decided 10 Dec 2010 Active
- FDA GUDID UDI-DI 08033390046961 listed 6 Apr 2016 Listed
Recalls
-
- Terminated Z-2539-2015
- Terminated Z-2540-2015
The dimensions of the mating features of the recalled products are out of specification causing the device to be difficult to assemble.
Timeline
- Cleared FDA 510(k) K100858
- Recall initiated FDA recalls Z-2539-2015
- Recall initiated FDA recalls Z-2540-2015
- Listed FDA GUDID 08033390046961
- Registered EUDAMED 80333902A064C2
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor EUDAMEDSMR Shoulder GUDID
- Generic name
- Orthopaedic implant impactor, reusable
- Model / Ref / Catalog
- 80333902A064C2, 9013.75.110, SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor, Glenoid Impactor
- Primary DI / UDI-DI
- 08033390046961
- Basic UDI-DI
- 80333902A064C2, B-08033390046961
- 510(k) Number
- FDA product code
- KWT, HSD
- EMDN code
- L091104, L091199
- GMDN term
- Orthopaedic implant impactor, reusable
- Device class
- Class IIa EUDAMEDClass I EUDAMEDClass II GUDID
- Regulation number
- 888.3650, 888.3690
- EU registration type
- Standard deviceLegacy device (under a directive)
- EU market of registration
- Italy
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 80333902A064C2 9013.75.110 SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor | Glenoid Impactor |
| Device class | Class IIa Class I | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC PROSTHESES POSITIONERS, REUSABLE.
- G7® 010002677 by Biomet Orthopedics, Inc.
- Persona® 42-5866-062-10 by Zimmer, Inc.
- WasherCap™ Inserter 7mm & 8mm ATMWCIN40 by ABANZA TECNOMED, S.L.
- Tornier Perform MWE046 by TORNIER, INC.
- Persona® 42-5891-004-30 by Zimmer, Inc.
- G7® 010002621 by Biomet Orthopedics, Inc.
- Nail Extractor D36039 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- Drill Guide C19012 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- 3655786 by MEDTRONIC SOFAMOR DANEK, INC.
- TRIGEN MAX 72800132 by Smith & Nephew, Inc.