SMR Shoulder Glenoid Impactor

by Limacorporate 3 variants

Part of a family of 25 devices: see the family page

Ref 9013.75.110Model 80333902A064C2, SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor

SMR Shoulder Glenoid Impactor (9013.75.110) is an orthopaedic implant impactor (EU MDD Class IIa; EU MDD Class I; FDA Class II) made by Limacorporate, registered in EUDAMED on 29 Oct 2026 (Basic UDI-DI 80333902A064C2), cleared under FDA 510(k) K100858 on 10 Dec 2010 and listed in FDA GUDID since 6 Apr 2016 (UDI-DI 08033390046961), active as of 7 Nov 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K100858

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED Number80333902A064C2 Basic UDI-DI 08033390046961UDI-DIDate29 Oct 2026RegisteredStatusActive
European UnionCE/MDR EUDAMED Number80333902A064C2 Basic UDI-DI 08033390046961UDI-DIDate29 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number08033390046961 UDI-DI Date6 Apr 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK100858 Date10 Dec 2010DecidedStatusActive

Official records

From the FDA record

Device description
SMALL/STD/LARGE MB Glenoid Impactor
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 80333902A064C2 registered 29 Oct 2026 Active· +1 more in the status table
  • FDA 510(k) K100858 decided 10 Dec 2010 Active
  • FDA GUDID UDI-DI 08033390046961 listed 6 Apr 2016 Listed

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-2539-2015 FDA Class II initiated 14 Aug 2015
    • Terminated Z-2540-2015 FDA Class II initiated 14 Aug 2015

    The dimensions of the mating features of the recalled products are out of specification causing the device to be difficult to assemble.

Timeline

5 dated events

  1. Cleared FDA 510(k) K100858
  2. Recall initiated FDA recalls Z-2539-2015
  3. Recall initiated FDA recalls Z-2540-2015
  4. Listed FDA GUDID 08033390046961
  5. Registered EUDAMED 80333902A064C2

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD, CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor EUDAMED
SMR Shoulder GUDID
Generic name
Orthopaedic implant impactor, reusable
Model / Ref / Catalog
80333902A064C2, 9013.75.110, SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor, Glenoid Impactor
Primary DI / UDI-DI
08033390046961
Basic UDI-DI
80333902A064C2, B-08033390046961
510(k) Number
FDA product code
KWT, HSD
EMDN code
L091104, L091199
GMDN term
Orthopaedic implant impactor, reusable
Device class
Class IIa EUDAMED
Class I EUDAMED
Class II GUDID
Regulation number
888.3650, 888.3690
EU registration type
Standard device
Legacy device (under a directive)
EU market of registration
Italy
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
80333902A064C2
9013.75.110
SMR Shoulder - SMALL/STD/LARGE MB Glenoid Impactor
GUDID
Glenoid Impactor
Device classEUDAMED
Class IIa
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa and Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes.

Similar devices in this category

Other devices filed under ORTHOPAEDIC PROSTHESES POSITIONERS, REUSABLE.

Other devices from Limacorporate

See all devices from Limacorporate →

Properties

  • Sterilise before use
  • Reusable
  • Prescription use
  • Lot / batch number
Other properties (21, all answered No)