SOMATOM Edge Plus 10267000
Part of a family of 20 devices: see the family page
Ref 10267000Model CT-Scanner_IIb_ERLN H 127
SOMATOM Edge Plus 10267000 is a device classified as Class IIb in the EU and Class II in the US made by Siemens Healthcare GmbH, registered in EUDAMED on 14 Apr 2026 (Basic UDI-DI 0405686900117UR), cleared under FDA 510(k) K230421 on 16 Jun 2023 (2 earlier submissions) and listed in FDA GUDID since 16 May 2018 (UDI-DI 04056869152684), active as of 12 Nov 2026. 16 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
4 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686900117UR 04056869152684 | Date14 Apr 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK230421 | Date16 Jun 2023 | StatusActive |
| United States | GUDID listing GUDID | Number04056869152684 | Date16 May 2018 | StatusListed |
Official records
- EUDAMED public site 0405686900117UR
- AccessGUDID record 04056869152684
- FDA 510(k) database K230421
- FDA 510(k) database K190578
- FDA 510(k) database K173607
Across registries
- EUDAMED Basic UDI-DI 0405686900117UR registered 14 Apr 2026 Active
- FDA 510(k) K230421 decided 16 Jun 2023 Active
- FDA GUDID UDI-DI 04056869152684 listed 16 May 2018 Listed
Recalls
-
- Ongoing Z-0475-2022
- Ongoing Z-0473-2022
- Ongoing Z-0474-2022
- Ongoing Z-0472-2022
Software version VB20_SP5 my lead to a relevant degradation of head image quality, a potential risk to patients is misdiagnosis.
-
- Terminated Z-0287-2022
- Terminated Z-0288-2022
- Terminated Z-0285-2022
- Terminated Z-0284-2022
- Terminated Z-0283-2022
- Terminated Z-0286-2022
- Terminated Z-0289-2022
software syngo.CT VB20 in the installed base, with or without syngo.CT software versions VB20_SP1, SP2, SP3, or SP4, may result in workflow interruptions resulting in the delay in diagnosis, the necessity for patient rescans, and/or the need for additional contrast media may occur
-
- Terminated Z-0771-2021
System does not trigger a cancel command followed by a reload of the scan with the new parameter(s). This issue may result in a delay in diagnosis and/or need for patient rescan
-
- Terminated Z-2440-2019
SOMATOM Definition Edge, SOMATOM Definition AS, SOMATOM Definition Flash with software syngo.CT with Software version VA48A_SP5 may result in scanning workflow interruptions and unexpected user notifications. and may result in a delay in diagnosis and/or patient rescans
-
- Terminated Z-2273-2019
- Terminated Z-2270-2019
Potential for four safety-related software issues impacting systems utilizing syngo.CT software version VB10A which may result in a scan abort.
-
- Terminated Z-1246-2019
Potential risk of scans being aborted when using the optional Dual Spiral Dual Engery mode due to a software issue found in syngo CT VB10A for the Siemens Healthineers CT scanners with a single X-ray tube.
Timeline
- Recall initiated FDA recalls Z-0284-2022
- Recall initiated FDA recalls Z-0283-2022
- Recall initiated FDA recalls Z-0286-2022
- Recall initiated FDA recalls Z-0289-2022
- Recall initiated FDA recalls Z-0475-2022
- Recall initiated FDA recalls Z-0473-2022
- Recall initiated FDA recalls Z-0474-2022
- Recall initiated FDA recalls Z-0472-2022
- Cleared FDA 510(k) K230421
- Registered EUDAMED 0405686900117UR
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- SOMATOM Edge Plus
- Generic name
- Full-body CT system
- Device name
- CT-Scanner_IIb_ERLN H 127
- Model / reference
- 10267000, CT-Scanner_IIb_ERLN H 127
- Primary DI / UDI-DI
- 04056869152684
- Basic UDI-DI
- 0405686900117UR
- FDA product code
- JAK
- EMDN code
- Z11030606 Computed tomographs - 128 layers or more but less than 256 layers
- GMDN term
- Full-body CT system
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1750
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under COMPUTED TOMOGRAPHS - 128 LAYERS OR MORE BUT LESS THAN 256 LAYERS.
- CT 5300 728285 by Philips Healthcare (Suzhou) Co., Ltd.
- System SOMATOM X.ceed 11330002 by Siemens Healthineers AG
- Revolution Ascend Select by GE Healthcare Japan Corporation
- Supria by FUJIFILM CORPORATION
- Revolution Ascend Elite by GE Healthcare Japan Corporation
- FCT iStream by FUJIFILM CORPORATION
- Photonova Spectra 5590000-50 by GE Medical Systems, L.L.C.
- CT Areta RT/Rembra RT Upgrades 728385 by Philips Healthcare (Suzhou) Co., Ltd.
- NeuViz Prime none by Neusoft Medical Systems Co., Ltd.
- Revolution Altitude Plus by GE HANGWEI MEDICAL SYSTEMS CO., LTD.