Stat Profile CCX
by Nova Biomedical Corporation 18 variants
Stat Profile CCX (35942) is a metabolic profile clinical chemistry analyser IVD (FDA Class II) made by Nova Biomedical Corporation, cleared under FDA 510(k) K013729 on 15 Jan 2002 and listed in FDA GUDID since 20 Sep 2016 (UDI-DI 00385480359429), active as of 23 Oct 2026.
Active
510(k)
Valid until
No expiry
FDA recalls
None found
Documents
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00385480359429 | Date20 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK013729 | Date15 Jan 2002 | StatusActive |
Official records
- AccessGUDID record 00385480359429
- FDA 510(k) database K013729
From the FDA record
- Device description
- Stat Profile Critical Care Express Analyzer
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K013729 decided 15 Jan 2002 Active
- FDA GUDID UDI-DI 00385480359429 listed 20 Sep 2016 Listed
Timeline
- Cleared FDA 510(k) K013729
- Listed FDA GUDID 00385480359429
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Stat Profile
- Generic name
- Metabolic profile clinical chemistry analyser IVD, portable, semi-automated
- Model / Ref / Catalog
- CCX, 35942
- Primary DI / UDI-DI
- 00385480359429
- 510(k) Number
- FDA product code
- CGZ, JPK, CGL, CHL, CDS, GKR, JGS, JFP, CGA, CFA, CEM, JKS, GHS, JIX, JJS, KHP, JPI
- GMDN term
- Metabolic profile clinical chemistry analyser IVD, portable, semi-automated
- Device class
- Class II
- Regulation number
- 862.1170, 864.8625, 862.1225, 862.1120, 862.1770, 864.5620, 862.1665, 862.1145, 862.1345, 862.1495, 862.1600, 862.3220, 864.7425, 862.1150, 862.1660, 862.1450, 864.6400
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code CGZ (ELECTRODE, ION-SPECIFIC, CHLORIDE).
- ISE REAGENTS FOR HITACHI 700 SERIES AND 911 CLINICAL CHEMISTRY SYSTEMS by Alko Diagnostic Corp.
- ISE REAGENTS FOR DEMAND ANALYZER by Advanced Biomedical Methods, Inc.
- VITROS Chemistry Products Cl- Slides by Ortho-Clinical Diagnostics
- AEROSET SYSTEM by Abbott Laboratories
- Dimension® QuikLYTE® Multisensor Flush Solution 10445051 S630 by Siemens Healthcare Diagnostics Inc.
- MODEL 644 SWEAT DILUENT by Ciba Corning Diagnostics Corp.
- HICHEM ISEKCI SOLUTION KIT 70010 by Hichem Diagnostics
- RAPIDLab® 1200 Series 1260 10321846 5062460 by Siemens Healthcare Diagnostics Inc.
- ARCHITECT 1E49-21 01E4921 by Abbott
- ABL90 FLEX, Clot catcher 906-026 by Radiometer Medical ApS