SunTech 98-0239-41
Part of a family of 31 devices: see the family page
Ref NJ118Model ABPM200
SunTech 98-0239-41 is a blood pressure ambulatory recorder (EU MDR Class I; FDA Class II; FDA product code DXN, System, Measurement, Blood-Pressure, Non-Invasive) made by SunTech Medical, Inc, registered in EUDAMED on 30 Oct 2026 (Basic UDI-DI 0840935100000000ABPM20078), cleared under FDA 510(k) K151520 on 19 Feb 2016 and listed in FDA GUDID since 23 Sep 2019 (UDI-DI 10840935108856), active as of 7 Nov 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0840935100000000ABPM20078 10840935108856 | Date30 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number10840935108856 | Date23 Sep 2019 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK151520 | Date19 Feb 2016 | StatusActive |
Official records
- EUDAMED public site 0840935100000000ABPM20078
- AccessGUDID record 10840935108856
- FDA 510(k) database K151520
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0840935100000000ABPM20078 registered 30 Oct 2026 Active
- FDA 510(k) K151520 decided 19 Feb 2016 Active
- FDA GUDID UDI-DI 10840935108856 listed 23 Sep 2019 Listed
Recalls
-
- Terminated Z-2429-2020
The device display, when activated, can show an incorrect decimal point when the blood pressure reading is a three-digit number and the unit of measure is set for mmHg.
-
- Terminated Z-0810-2020
The Bravo Mini (Model 250D), Agilis Mini (Model 250D), and NBP One (Model 250D) are being recalled because of a user safety issue when rechargeable batteries are misused in the product.
Timeline
- Cleared FDA 510(k) K151520
- Listed FDA GUDID 10840935108856
- Recall initiated FDA recalls Z-0810-2020
- Recall initiated FDA recalls Z-2429-2020
- Registered EUDAMED 0840935100000000ABPM20078
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- SunTech
- Generic name
- Blood pressure ambulatory recorder
- Device name
- Orbit Blood Pressure Cuff
- Model / reference
- ABPM200 EUDAMEDNJ118 EUDAMED98-0239-41 GUDID
- Primary DI / UDI-DI
- 10840935108856
- Basic UDI-DI
- 0840935100000000ABPM20078
- 510(k) Number
- FDA product code
- DXN
- EMDN code
- Z1203020302 Non–invasive blood pressure monitoring instruments
- GMDN term
- Blood pressure ambulatory recorder
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 870.1130
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | ABPM200 NJ118 | 98-0239-41 |
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under NON–INVASIVE BLOOD PRESSURE MONITORING INSTRUMENTS.
- Securmed ID-BDS by Jiangxi Securmed Medical Technology Co., Ltd
- UA-767S by A&D Company, Limited
- UM-102 by A&D Company, Limited
- BIOTRANS™ Pressure Monitoring Kits BTR-4812-3 (CAT#5510219)-GE 22-000813-30 by BIOPTIMAL INTERNATIONAL PTE. LTD.
- ati Care 25727335 by Ava Tajhiz Iranian
- NIBP Neo #1 Cuff 3.1 - 5.7 cm 2870181 by Draeger Medical Systems, Inc.
- NIBP Neo #2 Cuff 4.3 - 8 cm 2870199 by Draeger Medical Systems, Inc.
- BIOTRANS™ Pressure Monitoring Kits BTR4812-3 22-000813-23 by BIOPTIMAL INTERNATIONAL PTE. LTD.
- Upper arm blood pressure monitor AW150f by Rossmax Swiss GmbH
- Electronic Blood Pressure Monitor WHA20 by Shenzhen Jumper Medical Equipment Co.,Ltd