Skip to content

Synergy Cranial

by Medtronic Navigation Inc.

510(k) K150216

Synergy Cranial is a medical device (FDA Class II; FDA product code HAW, Neurological Stereotaxic Instrument) made by Medtronic Navigation Inc., cleared under FDA 510(k) K150216 on 11 Jun 2015, active as of 8 Nov 2026. 3 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK150216 Date11 Jun 2015ClearedStatusActive

Official records

From the FDA record

Received by the FDA
30 Jan 2015
FDA decision
11 Jun 2015 (Substantially Equivalent)
FDA review time
132 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K150216 (openFDA), as read on 8 Nov 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

3 recalls · 2 ongoing · FDA

    • Ongoing Z-1666-2023 FDA Class I initiated 11 Apr 2023

    In nonaxial/some axial exams if surgical plan utilized, Target Guidance selected, tip projection utilized, Navigate Projection enabled, software anomaly may occur during tumor resection/shunt placement/deep brain stimulation, where distance to/past target text no longer synchronized with navigation information, inaccurate value displayed; may result in prolonged/additional procedure, tissue injury

    • Ongoing Z-0383-2022 FDA Class I initiated 11 Nov 2021

    Cranial biopsy procedure software can enter a state where the biopsy depth gauge is no longer synchronized with the rest of the navigational information on the screen and may display an incorrect position of the biopsy needle, which may result in prolonged procedure, the need for additional surgical procedure, tissue injury.

    • Terminated Z-0552-2019 FDA Class I initiated 26 Sep 2018

    An incorrect display of the Biopsy Depth Gauge graphical representation in the Guidance View using Cranial software, which resulted in the biopsy of healthy tissue.

Timeline

4 dated events

  1. Cleared FDA 510(k) K150216
  2. Recall initiated FDA recalls Z-0552-2019
  3. Recall initiated FDA recalls Z-0383-2022
  4. Recall initiated FDA recalls Z-1666-2023

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
HAW
FDA applicant
Medtronic Navigation, Inc.
Device class
Class II
Regulation
21 CFR Part 882.4560
Advisory committee
Neurology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code HAW (Neurological Stereotaxic Instrument).

Other devices from Medtronic Navigation Inc.