TDI Head Neck Array
by GE Healthcare Coils 2 variants
Ref 5015300Model 1.5T TDI and Anterior Array
TDI Head Neck Array (5015300) is a MRI system coil (EU MDR Class I; FDA Class II) made by GE Healthcare Coils, registered in EUDAMED on 9 Feb 2024 (Basic UDI-DI 8406821BUG00312H2), cleared under FDA 510(k) K161567 on 1 Sep 2016 and listed in FDA GUDID since 28 Sep 2016 (UDI-DI 00840682120746), active as of 22 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
3 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00312H2 00840682120746 | Date9 Feb 2024 | StatusActive |
| United States | GUDID listing GUDID | Number00840682120746 | Date28 Sep 2016 | StatusListed |
| United States | FDA 510(k) GUDID | NumberK161567 | Date1 Sep 2016 | StatusActive |
Official records
- EUDAMED public site 8406821BUG00312H2
- AccessGUDID record 00840682120746
- FDA 510(k) database K161567
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00312H2 registered 9 Feb 2024 Active
- FDA 510(k) K161567 decided 1 Sep 2016 Active
- FDA GUDID UDI-DI 00840682120746 listed 28 Sep 2016 Listed
Recalls
-
- Ongoing Z-2300-2025
GE HealthCare has become aware that for certain MR systems (SIGNA Artist, SIGNA Voyager, Discovery MR450 1.5T, Optima MR450w 1.5T, SIGNA Architect, SIGNA Premier, SIGNA UHP, Discovery MR750 3.0T, Discovery MR750w 3.0T, SIGNA Hero, SIGNA PET/MR, SIGNA Artist Evo, SIGNA Voyager AIR (China Only), SIGNA Architect AIR (China Only), SIGNA Premier XT (China Only), SIGNA Premier Elite (China Only), SIGNA Premier MAX (China Only), SIGNA Hero XT (China Only), SIGNA Hero Elite (China Only), SIGNA Hero MAX (China Only), SIGNA PET/MR AIR (China Only), SIGNA PET/MR AIR Plus (China Only), the planned maintenance steps to check the functionality of the caster locks on the MR patient table may not have been performed.
-
- Ongoing Z-0599-2022
The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.
-
- Ongoing Z-2062-2021
GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed patient orientation on the system prior to running the initial 3-Plane Localizer Scan (See Figure 1 for reference to buttons.) Selecting and saving a patient orientation that does not match the patient's actual position may result in incorrectly annotated and/or flipped images.
-
- Terminated Z-0138-2022
Under certain conditions, some slices may be missing which can lead to a gap of anatomy in the 3D Volume images.
Timeline
- Cleared FDA 510(k) K161567
- Listed FDA GUDID 00840682120746
- Recall initiated FDA recalls Z-2062-2021
- Recall initiated FDA recalls Z-0138-2022
- Recall initiated FDA recalls Z-0599-2022
- Registered EUDAMED 8406821BUG00312H2
- Recall initiated FDA recalls Z-2300-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- MRI system coil, radio-frequency
- Device name
- 1.5T TDI and Anterior Array
- Model / Ref / Catalog
- 1.5T TDI and Anterior Array EUDAMED5015300 EUDAMEDTDI HEAD NECK ARRAY 5015300 GUDIDM7001ND GUDID
- Primary DI / UDI-DI
- 00840682120746
- Basic UDI-DI
- 8406821BUG00312H2
- 510(k) Number
- FDA product code
- LNH, MOS
- EMDN code
- Z1105018001 Magnetic resonance (MR) radiofrequency surface coils
- GMDN term
- MRI system coil, radio-frequency
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 892.1000
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 1.5T TDI and Anterior Array 5015300 | TDI HEAD NECK ARRAY 5015300 |
| Device class | Class I | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000001664
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under MAGNETIC RESONANCE (MR) RADIOFREQUENCY SURFACE COILS.
- 1.5T 16CH FLEX SPEEDER LARGE by NEOCOIL, LLC
- Vanguard for Siemens Breast MRI Auxiliary Table 300007108971 by Philips Medical Systems Nederland B.V.
- dS MSK S 1.5T by Philips Healthcare (Suzhou) Co., Ltd.
- Philips dS Base 3.0T 459801290092 by Philips Ds North America LLC
- Philips 4522-133-17141 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- 1.5T Receive-Only 16ch Flex SPEEDER Medium NC042200 by NEOCOIL, LLC
- Philips 4598-000-51951 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- Philips dS FootAnkle 16Ch 3.0T 459801295501 by Philips Ds North America LLC
- dS TorsoCardiac 1.5T 459801681991 by Philips Healthcare (Suzhou) Co., Ltd.
- Vanguard Breast MRI Table 453530385162 by Philips Medical Systems Nederland B.V.