Skip to content

ThermoCool SmartTouch D132704

by Biosense Webster Inc

ThermoCool SmartTouch D132704 is a cardiac radio-frequency ablation system catheter (FDA Class III; FDA product code LPB, Cardiac ablation percutaneous catheter) made by Biosense Webster Inc, approved under FDA PMA P040036 on 11 Aug 2006 (1 earlier submission) and listed in FDA GUDID since 10 Sep 2014 (UDI-DI 10846835009194), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

1 ongoing

Recall on shared PMA P030031; other models may be affected

Documents

PMA P040036

+1 more

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10846835009194 UDI-DI Date10 Sep 2014ListedStatusListed GUDID: in commercial distribution
United StatesFDA PMAAPPR from GUDID Approved NumberP040036 Date11 Aug 2006DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA PMA P040036 decided 11 Aug 2006 Active· +1 more in the status table
  • FDA GUDID UDI-DI 10846835009194 listed 10 Sep 2014 Listed

Recalls

8 recalls · 1 ongoing · FDA

    • Ongoing Z-0169-2023 FDA Class II initiated 7 Sep 2022 on shared PMA P030031

    Manufacturing error resulted in potential contamination of Bi-Directional navigation catheter irrigation path with cellulose fibers that can cause 1) Failure of initial flushing inspection, 2) Insufficient irrigation causing catheter tip temperature increase, limiting the ability to deliver ablation, or 3) particles flushed through the catheter irrigation may have thrombogenic/toxic effect.

    • Terminated Z-0139-2015 FDA Class II initiated 19 Oct 2014 catalog no. D132704 listed

    The recall was initiated because Biosense Webster is providing additional labeling for the safe and effective use of the ThermoCool SmartTouch Catheter.

  • 5 recalls, same reason

    • Terminated Z-0979-2012 FDA Unclassified (pre-2012) initiated 22 Nov 2010 on shared PMA P030031
    • Terminated Z-0980-2012 FDA Unclassified (pre-2012) initiated 22 Nov 2010 on shared PMA P030031
    • Terminated Z-0981-2012 FDA Unclassified (pre-2012) initiated 22 Nov 2010 on shared PMA P030031
    • Terminated Z-0982-2012 FDA Unclassified (pre-2012) initiated 22 Nov 2010 on shared PMA P030031
    • Terminated Z-0983-2012 FDA Unclassified (pre-2012) initiated 22 Nov 2010 on shared PMA P030031

    Biosense Webster, Inc. has recently become aware of the omission of the following two Warning and Precaution statements on the Instructions For Use (IFU) for the above catheter: 1. If phrenic nerve location is a concern, precautionary measures are recommended to evaluate the proximity of the nerve to the ablation electrode, such as pacing maneuvers. 2. To minimize risk of atrio-esophageal fist

    • Terminated Z-0057-06 FDA Unclassified (pre-2012) initiated 8 Aug 2005

    Increased complaints regarding catheters with leaks and flow obstruction.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

11 dated events

  1. Recall initiated FDA recalls Z-0057-06
  2. Approved FDA PMA P040036
  3. Recall initiated FDA recalls Z-0979-2012
  4. Recall initiated FDA recalls Z-0980-2012
  5. Recall initiated FDA recalls Z-0981-2012
  6. Recall initiated FDA recalls Z-0982-2012
  7. Recall initiated FDA recalls Z-0983-2012
  8. Listed FDA GUDID 10846835009194
  9. Recall initiated FDA recalls Z-0139-2015
  10. Recall initiated FDA recalls Z-0169-2023

1 earlier event are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

GUDID

Trade name
ThermoCool SmartTouch
Generic name
Cardiac radio-frequency ablation system catheter
Model / Ref / Catalog
D132704
Primary DI / UDI-DI
10846835009194
FDA product code
LPB
GMDN term
Cardiac radio-frequency ablation system catheter
Device class
Class III
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Cardiac radio-frequency ablation system catheter.

Other devices from Biosense Webster Inc

See all devices from Biosense Webster Inc →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)