Skip to content

Titanium Interference Screw 909668

by Biomet Orthopedics, Inc.

Ref 909668

Titanium Interference Screw 909668 is a tendon/ligament bone anchor (EU MDD Class IIb; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 26 Oct 2026 (Basic UDI-DI B-00880304008304), cleared under FDA 510(k) K193451 on 24 Feb 2020 (1 earlier submission) and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 00880304008304), active as of 7 Nov 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00880304008304 Basic UDI-DI 00880304008304UDI-DIDate26 Oct 2026RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK193451 Date24 Feb 2020DecidedStatusActive
United StatesGUDID listing GUDID Number00880304008304 UDI-DI Date24 Oct 2015ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00880304008304 registered 26 Oct 2026 Active
  • FDA 510(k) K193451 decided 24 Feb 2020 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00880304008304 listed 24 Oct 2015 Listed

Recalls

2 recalls · FDA

    • Terminated Z-0630-2021 FDA Class II initiated 25 Nov 2020

    Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device.

    • Terminated Z-0753-2013 FDA Class II initiated 3 Jan 2013

    Thru hole at the tip of the screw is undersized.

Timeline

6 dated events

  1. Cleared FDA 510(k) K934469
  2. Recall initiated FDA recalls Z-0753-2013
  3. Listed FDA GUDID 00880304008304
  4. Cleared FDA 510(k) K193451
  5. Recall initiated FDA recalls Z-0630-2021
  6. Registered EUDAMED B-00880304008304

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Titanium Interference Screw
Generic name
Tendon/ligament bone anchor, non-bioabsorbable
Device name
Round Head TI Interference Screw Implant
Model / Ref / Catalog
909668
Primary DI / UDI-DI
00880304008304
Basic UDI-DI
B-00880304008304
510(k) Number
FDA product code
HWC, MBI
EMDN code
P09120605 Interference screws
GMDN term
Tendon/ligament bone anchor, non-bioabsorbable
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
888.3040
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
MRI safety
MR Conditional

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under INTERFERENCE SCREWS.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)