ToggleLoc With Ziploop 904756
Ref 904756
ToggleLoc With Ziploop 904756 is a tendon/ligament bone anchor (EU MDD Class IIb; FDA Class II) made by Biomet Orthopedics, Inc., registered in EUDAMED on 20 Oct 2026 (Basic UDI-DI B-00880304464223), cleared under FDA 510(k) K130033 on 1 Aug 2013 (3 earlier submissions) and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 00880304464223), active as of 25 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00880304464223 00880304464223 | Date20 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00880304464223 | Date24 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK130033 | Date1 Aug 2013 | StatusActive |
Official records
- EUDAMED public site B-00880304464223
- AccessGUDID record 00880304464223
- FDA 510(k) database K130033
- FDA 510(k) database K083070
- FDA 510(k) database K033838
- FDA 510(k) database K973775
From the FDA record
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-00880304464223 registered 20 Oct 2026 Active
- FDA 510(k) K130033 decided 1 Aug 2013 Active
- FDA GUDID UDI-DI 00880304464223 listed 24 Oct 2015 Listed
Recalls
-
- Ongoing Z-0212-2026
There is a potential for a missing slotted button assembly in one lot of ZipTight, Acute AC Joint Implant, Single Ziploop
-
- Terminated Z-0818-2018
Ziptight Ankle Syndesmosis Fixation was packaged without the tip protectors.
-
- Terminated Z-1828-2016
Insufficient seal strength on sterile barrier packaging. The seal could be jeopardized causing the sterile barrier to be compromised and the product could become nonsterile. If the product becomes non-sterile and is used or implanted, it may lead to an infection.
-
- Terminated Z-1363-2015
The firm is recalling ToggleLocs and Ziploops manufactured in May and July of 2014 as they were not processed following a standard work process, which resulted in complaints of sterile packaging not being sealed.
-
- Terminated Z-1953-2010
- Terminated Z-1952-2010
The firm has received complaints that the saddle is too long. The saddle is supposed to be between 7/8 and 1 1/8 inches long. The saddle in the complaints was up to 1.9 inches long.
-
- Terminated Z-0560-2010
- Terminated Z-0559-2010
Packages labeled as containing a stainless steel device actually contain a titanium device, and vice versa.
-
- Terminated Z-0582-2012
Six sizes of ToggleLoc, Artificial Ligament Fixation Device, have been manufactured with the suture pull hole drilled in the wrong location on the device. The ToggleLoc implant is deployed with a suture that pulls the device through the tunnel. The hole being drilled in the wrong location will orient the device to pass through the tunnel with the angled end of the implant first. This may caus
Timeline
- Recall initiated FDA recalls Z-0559-2010
- Recall initiated FDA recalls Z-1953-2010
- Recall initiated FDA recalls Z-1952-2010
- Cleared FDA 510(k) K130033
- Recall initiated FDA recalls Z-1363-2015
- Listed FDA GUDID 00880304464223
- Recall initiated FDA recalls Z-1828-2016
- Recall initiated FDA recalls Z-0818-2018
- Recall initiated FDA recalls Z-0212-2026
- Registered EUDAMED B-00880304464223
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- ToggleLoc With Ziploop
- Generic name
- Tendon/ligament bone anchor, non-bioabsorbable
- Device name
- TLoc Extension TI Button with Continuous Loop Implant Assemb
- Model / Ref / Catalog
- 904756
- Primary DI / UDI-DI
- 00880304464223
- Basic UDI-DI
- B-00880304464223
- FDA product code
- JDR, MBI
- EMDN code
- P0999 Orthopaedic prostheses, osteosynthesis devices, devices for tendon and ligament synthesis - other
- GMDN term
- Tendon/ligament bone anchor, non-bioabsorbable
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3030, 888.3040
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under ORTHOPAEDIC PROSTHESES, OSTEOSYNTHESIS DEVICES, DEVICES FOR TENDON AND LIGAMENT SYNTHESIS - OTHER.
- FlareHawk Interbody Fusion System FHTPKW1 by Integrity Implants Inc.
- Allen O-ASLW by HILL-ROM, INC.
- Allen O-AWLH by HILL-ROM, INC.
- CONTOUR MENISCUS ARROW 541110 by Conmed Corporation
- Poly-Tape 10 x 500mm 102-1010 by Xiros Limited
- Poly-Tape 10 x 800mm 102-1080 by Xiros Limited
- SMARTPIN 121520 by Conmed Corporation
- General Instrument 11-1500-005 by ORTHOPEDIATRICS CORP.
- OrthoPediatrics Cannulated Screw System 01-1400-0400 by ORTHOPEDIATRICS CORP.