Trilogy Evo Universal DS2000X11B
Trilogy Evo Universal DS2000X11B is a portable electric ventilator (FDA Class II) made by Respironics Inc., cleared under FDA 510(k) K181170 on 18 Jul 2019 and listed in FDA GUDID since 26 Feb 2020 (UDI-DI 00606959052000), active as of 23 Oct 2026. 13 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
13 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00606959052000 | Date26 Feb 2020 | StatusListed |
| United States | FDA 510(k)SESE | NumberK181170 | Date18 Jul 2019 | StatusActive |
Official records
- AccessGUDID record 00606959052000
- FDA 510(k) database K181170
From the FDA record
- Device description
- Trilogy Evo Universal Ventilator
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K181170 decided 18 Jul 2019 Active
- FDA GUDID UDI-DI 00606959052000 listed 26 Feb 2020 Listed
Recalls
-
- Ongoing Z-1617-2026
Using non-pneumatic nebulizers with Trilogy Evo Platform ventilators may result in a discrepancy between the set tidal volume and the tidal volume received by the patient.
-
- Ongoing Z-1649-2026
In some situations, the Obstruction Alarm does not trigger within the timeframe dictated by the relevant standards and may take up to four breaths.
-
- Ongoing Z-0292-2025
Potential for in-line nebulizer configuration in certain locations to result in aerosol deposit accumulation on the device's internal flow sensor, which could lead to inaccurate flow measurements.
-
- Ongoing Z-2943-2024
- Ongoing Z-2944-2024
- Ongoing Z-2942-2024
Firm has released a mandatory software update Version 1.05.10.00 and a User Manual addendum for affected ventilators. These updates resolve safety issues identified in earlier recalls.
-
- Ongoing Z-1504-2024
- Ongoing Z-1505-2024
Potential for sudden loss of ventilation due to Battery Depleted or Loss of Power alarm while unit has sufficient power.
-
- Ongoing Z-1652-2023
The Trilogy Evo Universal ventilator provides continuous or intermittent positive pressure ventilation for the care of individuals who require mechanical ventilation. Trilogy Evo Universal is intended for pediatric through adult patients weighing at least 2.5 kg. The ventilator can measure, display, record, and alarm SpO2, FiO2, CO2, and pulse rate data when integrated with the appropriate accessories. The ventilator is suitable for use in institutional and hospital settings and non-emergency transport settings; for example, wheelchair. It may be used for both invasive and non-invasive ventilation.
-
- Ongoing Z-1289-2023
The accuracy of delivered oxygen may deviate below the required tolerance of 5% from setpoint when providing high concentration oxygen therapy. Additionally, if equipped, the internal FiO2 sensor may indicate a value higher than the device is actually delivering. This may lead to under delivery of oxygen.
-
- Ongoing Z-0493-2022
- Ongoing Z-0494-2022
Philips has identified a specific lot of non-conforming material manufactured by one of its suppliers. A Philips supplier incorrectly used polyester-based polyurethane (PE-PUR) sound abatement foam, a non-conforming material in the devices and repair kits. PE-PUR foam may degrade into particles which may enter the device s air pathway and be ingested or inhaled by the user. The foam degradation may be exacerbated by use of unapproved cleaning methods such as unapproved ozone cleaners, and the PE-PUR foam may off-gas certain chemicals during initial use of the device.
-
- Ongoing Z-2290-2021
Two software issues have been identified related to pressure increase in the device: The first issue is described as "Infant/Pediatric EFS Calibration Pressure Increase" and the second issue is described as "Pressure Drift (Continuous Usage).
Timeline
- Recall initiated FDA recalls Z-1289-2023
- Recall initiated FDA recalls Z-1652-2023
- Recall initiated FDA recalls Z-1504-2024
- Recall initiated FDA recalls Z-1505-2024
- Recall initiated FDA recalls Z-2943-2024
- Recall initiated FDA recalls Z-2944-2024
- Recall initiated FDA recalls Z-2942-2024
- Recall initiated FDA recalls Z-0292-2025
- Recall initiated FDA recalls Z-1617-2026
- Recall initiated FDA recalls Z-1649-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Trilogy Evo Universal
- Generic name
- Portable electric ventilator
- Model / Ref / Catalog
- DS2000X11B
- Primary DI / UDI-DI
- 00606959052000
- 510(k) Number
- FDA product code
- CBK, NOU
- GMDN term
- Portable electric ventilator
- Device class
- Class II
- Regulation number
- 868.5895
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code CBK (Ventilator, continuous, facility use).
- PURITAN-BENNETT 840 VENTILATIOR SYSTEM WITH VOLUME VENTILATION PLUS OPTION by Puritan Bennett Corp.
- PURITAN-BENNETT 7200SPI MICROPROCESSOR VENTILATOR by Puritan Bennett Corp.
- VEOLAR VENTILATOR by HAMILTON MEDICAL, INC.
- bellavista 302.396.000-40 by Zoll Medical Corporation
- Ventoux Patient Circuit VX64-0006 by FLIGHT MEDICAL INNOVATIONS LTD
- Ventoux VC3 VX-12-0-MN0 by FLIGHT MEDICAL INNOVATIONS LTD
- VENTILATOR ADULT STAR MODIFICATION by Infrasonics Corp.
- PB 840 VENTILATOR SYSTEM WITH LEAK COMPENSATION OPTION, MODEL 840 by Covidien, Formerly Nellcor Puritan Bennett, Inc.
- PURITAN BENNETT LEGENDAIR XL2 by Nellcor Puritan Bennett, Inc.
- Evita V800, Evita V600 by Draegerwerk AG & Co. KGaA