88000057
by Shanghai United Imaging Healthcare Co., Ltd.
Ref 88000057Model uMI 550
88000057 is a PET/CT system (EU MDR Class IIb; FDA Class II) made by Shanghai United Imaging Healthcare Co., Ltd., registered in EUDAMED on 22 Feb 2024 (Basic UDI-DI B-06971576832026), cleared under FDA 510(k) K210001 on 30 Apr 2021 (4 earlier submissions) and listed in FDA GUDID since 3 Apr 2019 (UDI-DI 06971576832026), active as of 22 Oct 2026. 10 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
7 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | NumberB-06971576832026 06971576832026 | Date22 Feb 2024 | StatusActive |
| European Union | CE/MDD EUDAMED | NumberB-06971576832026 06971576832026 | Date22 Feb 2024 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK210001 | Date30 Apr 2021 | StatusActive |
| United States | GUDID listing GUDID | Number06971576832026 | Date3 Apr 2019 | StatusListed |
Official records
- EUDAMED public site B-06971576832026
- AccessGUDID record 06971576832026
- FDA 510(k) database K210001
- FDA 510(k) database K210418
- FDA 510(k) database K193210
- FDA 510(k) database K193241
- FDA 510(k) database K182237
From the FDA record
- Device description
- Positron Emission Tomography and Computed Tomography System
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI B-06971576832026 registered 22 Feb 2024 Active
- FDA 510(k) K210001 decided 30 Apr 2021 Active
- FDA GUDID UDI-DI 06971576832026 listed 3 Apr 2019 Listed
Recalls
-
- Ongoing Z-3283-2026
Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on the Patient Administration interface, which may result in the need for rescans.
-
- Ongoing Z-0223-2026
Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.
-
- Ongoing Z-1353-2023
Due to a software issue where the process of patient scanning, the scatter correction may occasionally fail with will potentially cause a failure of the PET image reconstruction and generation of PET images.
-
- Ongoing Z-0087-2023
The wireless VSM module of a mobile PET/CT system, operating in an environment with strong Wi-Fi signals, may experience ECG signal and respiratory signal loss due to Wi-Fi interference. ECG and respiratory signal loss during acquisition can result in the failure of ECG and respiratory-gated reconstruction of the PET scan, which may require rescanning of the patient.
-
- Ongoing Z-2593-2021
- Ongoing Z-2594-2021
The EXAM acquisition workflow could occasionally freeze after canceling the PET scan.
-
- Ongoing Z-0448-2021
A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.
-
- Terminated Z-2800-2020
1) Service function problem may cause false marking of a bad channel resulting in ring artifacts; 2) Potential intermittent scout scanning interruption due to angle signal drift caused by external interference; 3) Metal edge overlap of mylar strip in gantry may create sharp edge. May lead to repeat scanning and abrasions (N/A for Serial No. 200036)
-
- Terminated Z-2819-2020
In affected software version, of Positron emission tomography and computed tomography system, the CT Hounsfield unit curve may not display in real time when using the bolus tracking protocol with the tracker scan function. If this occurs, the subsequent clinical scanning protocols will need to be started manually, which may effect image enhancement, and may result in patient rescan.
-
- Terminated Z-1708-2020
Potential sporadic software bugs in R001.3.0.0.750505 software version may cause an issue with the PET acquisition raw data causing reconstruction problems during PET/CT scanning and could possibly cause rescans of patients with additional dose.
Timeline
- Recall initiated FDA recalls Z-0448-2021
- Cleared FDA 510(k) K210418
- Cleared FDA 510(k) K210001
- Recall initiated FDA recalls Z-2593-2021
- Recall initiated FDA recalls Z-2594-2021
- Recall initiated FDA recalls Z-0087-2023
- Recall initiated FDA recalls Z-1353-2023
- Registered EUDAMED B-06971576832026
- Recall initiated FDA recalls Z-0223-2026
- Recall initiated FDA recalls Z-3283-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- uMI
- Generic name
- PET/CT system
- Model / reference
- uMI 550, 88000057
- Primary DI / UDI-DI
- 06971576832026
- Basic UDI-DI
- B-06971576832026, 697157683202N2
- FDA product code
- KPS, JAK
- EMDN code
- Z11020301 CT/pet systems
- GMDN term
- PET/CT system
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1200, 892.1750
- EU registration type
- Legacy device (under a directive)Standard device
- EU market of registration
- Poland
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- CN-MF-000008501
- Authorised representative
- Shanghai International Holding Corp. GmbH(Europe) DE-AR-000000001
Similar devices in this category
Other devices filed under CT/PET SYSTEMS.
- SpotLight Duo 07290016484052 by Arineta, Ltd.
- Omni PCM-PET0014 by GE Medical Systems Israel, Functional Imaging
- CardioGraphe Spotlight by Arineta, Ltd.
- Vereos PET/CT 882446 by Philips Medical Systems Nederland B.V.
- Omni Legend PCM-PET0012 by GE Medical Systems, LLC
- Discovery IQ PCM-PET0008A by GE Medical Systems, LLC
- Discovery MI by GE Medical Systems, L.L.C.
- Vereos PET/CT System Upgrade 882425 by Philips Medical Systems Nederland B.V.
Other devices from Shanghai United Imaging Healthcare Co., Ltd.
See all devices from Shanghai United Imaging Healthcare Co., Ltd. →