Skip to content

88000057

by Shanghai United Imaging Healthcare Co., Ltd.

Ref 88000057Model uMI 550

88000057 is a PET/CT system (EU MDR Class IIb; FDA Class II) made by Shanghai United Imaging Healthcare Co., Ltd., registered in EUDAMED on 22 Feb 2024 (Basic UDI-DI B-06971576832026), cleared under FDA 510(k) K210001 on 30 Apr 2021 (4 earlier submissions) and listed in FDA GUDID since 3 Apr 2019 (UDI-DI 06971576832026), active as of 22 Oct 2026. 10 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

7 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED NumberB-06971576832026 Basic UDI-DI 06971576832026UDI-DIDate22 Feb 2024RegisteredStatusActive
European UnionCE/MDD EUDAMED NumberB-06971576832026 Basic UDI-DI 06971576832026UDI-DIDate22 Feb 2024RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK210001 Date30 Apr 2021DecidedStatusActive
United StatesGUDID listing GUDID Number06971576832026 UDI-DI Date3 Apr 2019ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Positron Emission Tomography and Computed Tomography System
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 29 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-06971576832026 registered 22 Feb 2024 Active· +1 more in the status table
  • FDA 510(k) K210001 decided 30 Apr 2021 Active· +4 more in the status table
  • FDA GUDID UDI-DI 06971576832026 listed 3 Apr 2019 Listed

Recalls

10 recalls · 7 ongoing · FDA

    • Ongoing Z-3283-2026 FDA Class II initiated 11 Aug 2026 UDI-DI 06971576832026 listed

    Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on the Patient Administration interface, which may result in the need for rescans.

    • Ongoing Z-0223-2026 FDA Class II initiated 12 Sep 2025 UDI-DI 06971576832026 listed

    Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.

    • Ongoing Z-1353-2023 FDA Class II initiated 1 Mar 2023 UDI-DI 06971576832026 listed

    Due to a software issue where the process of patient scanning, the scatter correction may occasionally fail with will potentially cause a failure of the PET image reconstruction and generation of PET images.

    • Ongoing Z-0087-2023 FDA Class II initiated 30 May 2022 UDI-DI 06971576832026 listed

    The wireless VSM module of a mobile PET/CT system, operating in an environment with strong Wi-Fi signals, may experience ECG signal and respiratory signal loss due to Wi-Fi interference. ECG and respiratory signal loss during acquisition can result in the failure of ECG and respiratory-gated reconstruction of the PET scan, which may require rescanning of the patient.

  • 2 recalls, same reason

    • Ongoing Z-2593-2021 FDA Class II initiated 2 Aug 2021 UDI-DI 06971576832026 listed
    • Ongoing Z-2594-2021 FDA Class II initiated 2 Aug 2021

    The EXAM acquisition workflow could occasionally freeze after canceling the PET scan.

    • Ongoing Z-0448-2021 FDA Class II initiated 5 Aug 2020 UDI-DI 06971576832026 listed

    A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.

    • Terminated Z-2800-2020 FDA Class II initiated 16 Jul 2020

    1) Service function problem may cause false marking of a bad channel resulting in ring artifacts; 2) Potential intermittent scout scanning interruption due to angle signal drift caused by external interference; 3) Metal edge overlap of mylar strip in gantry may create sharp edge. May lead to repeat scanning and abrasions (N/A for Serial No. 200036)

    • Terminated Z-2819-2020 FDA Class II initiated 26 Mar 2020 UDI-DI 06971576832026 listed

    In affected software version, of Positron emission tomography and computed tomography system, the CT Hounsfield unit curve may not display in real time when using the bolus tracking protocol with the tracker scan function. If this occurs, the subsequent clinical scanning protocols will need to be started manually, which may effect image enhancement, and may result in patient rescan.

    • Terminated Z-1708-2020 FDA Class II initiated 26 Aug 2019 UDI-DI 06971576832026 listed

    Potential sporadic software bugs in R001.3.0.0.750505 software version may cause an issue with the PET acquisition raw data causing reconstruction problems during PET/CT scanning and could possibly cause rescans of patients with additional dose.

Timeline

17 dated events

  1. Recall initiated FDA recalls Z-0448-2021
  2. Cleared FDA 510(k) K210418
  3. Cleared FDA 510(k) K210001
  4. Recall initiated FDA recalls Z-2593-2021
  5. Recall initiated FDA recalls Z-2594-2021
  6. Recall initiated FDA recalls Z-0087-2023
  7. Recall initiated FDA recalls Z-1353-2023
  8. Registered EUDAMED B-06971576832026
  9. Recall initiated FDA recalls Z-0223-2026
  10. Recall initiated FDA recalls Z-3283-2026

7 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR, CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
uMI
Generic name
PET/CT system
Model / reference
uMI 550, 88000057
Primary DI / UDI-DI
06971576832026
Basic UDI-DI
B-06971576832026, 697157683202N2
FDA product code
KPS, JAK
EMDN code
Z11020301 CT/pet systems
GMDN term
PET/CT system
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1200, 892.1750
EU registration type
Legacy device (under a directive)
Standard device
EU market of registration
Poland
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CN-MF-000008501
Authorised representative
Shanghai International Holding Corp. GmbH(Europe) DE-AR-000000001

Similar devices in this category

Other devices filed under CT/PET SYSTEMS.

Other devices from Shanghai United Imaging Healthcare Co., Ltd.

See all devices from Shanghai United Imaging Healthcare Co., Ltd. →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)