Venclose System Power Cord VCPCM
by Venclose Inc
Venclose System Power Cord VCPCM is an electrical mains power cable (FDA Class II; FDA product code GEI, Electrosurgical, Cutting & Coagulation & Accessories) made by Venclose Inc, cleared under FDA 510(k) K160754 on 9 Sep 2016, registered in EUDAMED and listed in FDA GUDID since 1 Nov 2016 (UDI-DI 00858254006121), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number00858254006121 | Date1 Nov 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK160754 | Date9 Sep 2016 | StatusActive |
| European Union | CE/MDR EUDAMED | Number— | Date— | StatusActive |
Official records
- EUDAMED public site
- AccessGUDID record 00858254006121
- FDA 510(k) database K160754
From the FDA record
- Device description
- Power Cord, India
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K160754 decided 9 Sep 2016 Active
- EUDAMED Active
- FDA GUDID UDI-DI 00858254006121 listed 1 Nov 2016 Listed
Recalls
-
- Ongoing Z-2638-2025
Software version 3.35 of the Venclose digiRF Generator incorporates a catheter verification feature specifically designed to detect internal wiring anomalies in Venclose EVSRF Ablation Catheters prior to clinical use. This automated diagnostic check is executed immediately upon catheter connection to the generator, occurring before the procedure interface becomes accessible. When a catheter fails this verification process, the generator displays a Red X indicator on the screen without accompanying error codes, effectively disabling catheter functionality. However, BD has determined that software version 3.35 generates false positive failures due to temperature-dependent verification parameters, incorrectly flagging properly functioning Venclose EVSRF Ablation Catheters as defective when the catheter temperature is not at steady state during the check initiation.
-
- Ongoing Z-0371-2025
The Venclose" RF Ablation Catheters may have been manufactured with internal wiring error. The red and yellow signal wires were soldered on swapped ports of the catheter PCB. This error in wire configuration would lead to power being applied through the proximal 3/4th of the heating coil, bypassing the thermocouple, which will then cause the generator to overdrive the catheter in an attempt to reach desired temperature set point. The wire attachment error causes the device to reach temperatures exceeding the levels intended for therapeutic efficacy, while the console is falsely indicating that temperature has not yet been reached, thus increasing the risk of harm due to excessive temperature.
Timeline
- Cleared FDA 510(k) K160754
- Listed FDA GUDID 00858254006121
- Recall initiated FDA recalls Z-0371-2025
- Recall initiated FDA recalls Z-2638-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Venclose System Power Cord
- Generic name
- Electrical mains power cable
- Model / reference
- VCPCM
- Primary DI / UDI-DI
- 00858254006121
- 510(k) Number
- FDA product code
- GEI
- GMDN term
- Electrical mains power cable
- Device class
- Class II
- Regulation number
- 878.4400
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category