Veritas Advanced Fluidics Pack VRT-AF
by Johnson & Johnson Surgical Vision, Inc.
Ref VRT-AF
Veritas Advanced Fluidics Pack VRT-AF is a surgical irrigation/aspiration tubing set (EU MDR Class IIa; FDA Class II; FDA product code HQC, Unit, phacofragmentation) made by Johnson & Johnson Surgical Vision, Inc., registered in EUDAMED on 3 Aug 2026 (Basic UDI-DI 5050474a000159D) and listed in FDA GUDID since 20 Apr 2021 (UDI-DI 05050474700895), active as of 24 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingDocuments
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number5050474a000159D 05050474700895 | Date3 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number05050474700895 | Date20 Apr 2021 | StatusListed |
Official records
- EUDAMED public site 5050474a000159D
- AccessGUDID record 05050474700895
From the FDA record
- Device description
- VERITAS ADVANCED FLUIDICS PACK
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 5050474a000159D registered 3 Aug 2026 Active
- FDA GUDID UDI-DI 05050474700895 listed 20 Apr 2021 Listed
Recalls
-
- Ongoing Z-2247-2023
Weld protrusion/physical gap between the housing and pack cover, may exceed design specification, due to a manufacturing issue, which could lead to priming cycle failure and/or suboptimal vacuum delivered to the phacoemulsification and irrigation/aspiration handpieces during surgery, which could result in surgical delay and/or longer surgical time, which could result in transient corneal edema.
Timeline
- Listed FDA GUDID 05050474700895
- Recall initiated FDA recalls Z-2247-2023
- Registered EUDAMED 5050474a000159D
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Veritas Advanced Fluidics Pack
- Generic name
- Surgical irrigation/aspiration tubing set
- Device name
- Phaco Tubing Pack
- Model / Ref / Catalog
- VRT-AF
- Primary DI / UDI-DI
- 05050474700895
- Basic UDI-DI
- 5050474a000159D
- FDA product code
- HQC
- EMDN code
- Z1212020785 Phaco-vitrectomy instruments - consumables
- GMDN term
- Surgical irrigation/aspiration tubing set
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 886.4670
- EU registration type
- Standard device
- EU market of registration
- Ireland
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under PHACO-VITRECTOMY INSTRUMENTS - CONSUMABLES.
- TRAY COVER QUATERA 700 303061-9112-000 by Carl Zeiss Meditec AG
- Blue infusion sleeve for 3004.FD & 3006.PF phaco needles 3003 by D.O.R.C. Dutch Ophthalmic Research Center (International) B.V.
- Disposable High Myopic Backflush instrument, with brush needle and active aspira 1281.BTDH5 by D.O.R.C. Dutch Ophthalmic Research Center (International) B.V.
- Unity VCS (8065000296); Unity CS (8065000297) by Alcon Laboratories, Inc.
- IRR & ASP HANDPIECES BIMANUAL 303060-0165-000 by Carl Zeiss Meditec AG
- Alcon, Intrepid 8065752144 by Alcon Laboratories, Inc.
- OPHTHALMIC SURGICAL SYSTEM CV-9000 Cubeα_B01E001 by NIDEK CO., LTD.
- OPHTHALMIC SURGICAL SYSTEM CV-30000 Fortas_B01E007 by NIDEK CO., LTD.
Other devices from Johnson & Johnson Surgical Vision, Inc.
See all devices from Johnson & Johnson Surgical Vision, Inc. →