Vitrea

by Canon Medical Informatics, Inc. 9 variants

Part of a family of 10 devices: see the family page

Ref 7.16.3.SU01

Vitrea (7.16.3.SU01) is a device classified as Class IIa in the EU and Class II in the US made by Canon Medical Informatics, Inc., registered in EUDAMED on 20 Sep 2023 (Basic UDI-DI 0850025268VitreaAVES), cleared under FDA 510(k) K223261 on 13 Jul 2023 (18 earlier submissions) and listed in FDA GUDID since 24 Sep 2025 (UDI-DI 00850025268370), withdrawn (EUDAMED), active (FDA 510(k)) as of 24 Oct 2026. 7 FDA recalls are linked to it.

Active Active in United States. Withdrawn in European Union. Also listed in GUDID (US).

CE MDR, withdrawn 510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

7 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number00850025268370 UDI-DI Date24 Sep 2025ListedStatusListed GUDID: in commercial distribution
European UnionCE/MDR EUDAMED Number0850025268VitreaAVES Basic UDI-DI 00850025268370UDI-DIDate20 Sep 2023RegisteredStatusWithdrawn No longer placed on the EU market
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK223261 Date13 Jul 2023DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0850025268VitreaAVES registered 20 Sep 2023 Withdrawn
  • FDA 510(k) K223261 decided 13 Jul 2023 Active· +18 more in the status table
  • FDA GUDID UDI-DI 00850025268370 listed 24 Sep 2025 Listed

Recalls

7 recalls · FDA

    • Terminated Z-0169-2014 FDA Class II initiated 21 Oct 2013

    Vital Images, Inc. has found an issue in VitreaCore software though internal testing. There is a potential for incorrect and possibly reversed image orientation for certain snapshots taken in VitreaCore software versions 6.0, 6.1, 6.2, 6.3 (except 6.3.1), 6.4 (except 6.4.4 and 6.4.5), as well as their upgrades, and 6.5.

    • Terminated Z-1181-2013 FDA Class II initiated 15 Mar 2013

    Vital Images, Inc. (Vital Images) received one report about potential user confusion when viewing a brain perfusion scan on Vitrea CT Brain Perfusion 2D when the scan was performed using a wide coverage shuttle acquisition technique. This may result in patient treatment delays, misdiagnosis or mistreatment.

    • Terminated Z-1144-2013 FDA Class II initiated 15 Mar 2013

    Vital Images has made a decision to perform a field correction to the Vitrea CT Multi-Chamber Cardiac Functional Analysis application. Vital Images has identified a defect in which numerical values may be incorrect in the Results Table under the Cardiac Analysis portion of the user interface.

    • Terminated Z-0186-2013 FDA Class II initiated 13 Aug 2012

    Vital Images has found two potential errors in calcium score values in restored snapshots of studies generated through use of Vitrea or Vitrea Enterprise Suite. This issue affects Version 3.1 of Vitrea fX; Version 5.2 of Vitrea; Versions 6.0, 6.1 and 6.2 of Vitrea and Vitrea fX; and Versions 1.3, 6.0, 6.1 and 6.2 of Vitrea Enterprise Suite; and all updates to those versions.

    • Terminated Z-0388-2012 FDA Unclassified (pre-2012) initiated 11 Nov 2011

    Vital Images has found two issues that may display incorrect Standard Update Values (SUV) when viewing certain PET/CT images. This issue affects the VitreaCore PET/CT feature for Vitrea Enterprise Suite 1.2, 1.3, 6.0, 6.1, including all updates to those versions.

    • Terminated Z-1021-2011 FDA Unclassified (pre-2012) initiated 23 Aug 2010

    There is a potential alignment error of fused PET/CT images in the Vitrea Core component of Vitrea Enterprise Suite 1.2 and 1.3. The error occurs during panning of the fused PET/CT images. Because the PET data has a larger voxel size than the CT data, it is possible to pan the CT image in more frequent, smaller steps than the PET image, so that the fused PET image does not move until the CT data

    • Terminated Z-0520-2008 FDA Unclassified (pre-2012) initiated 8 Nov 2007

    Standard Uptake Values (SUV) display/update problems; in the way Standard Uptake Values (SUV) are displayed in 3D/MPR views. The problem arises when a user draws a selected region of interest in order to calculate the SUV statistics of the region. If the user then changes the slice shown by scrolling through additional slices, the original SUV measurements will remain on the screen and do not up

Timeline

28 dated events

  1. Cleared FDA 510(k) K151283
  2. Cleared FDA 510(k) K160150
  3. Cleared FDA 510(k) K161157
  4. Cleared FDA 510(k) K172855
  5. Cleared FDA 510(k) K182230
  6. Cleared FDA 510(k) K181247
  7. Cleared FDA 510(k) K222662
  8. Cleared FDA 510(k) K223261
  9. Registered EUDAMED 0850025268VitreaAVES
  10. Listed FDA GUDID 00850025268370

18 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Withdrawn
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Vitrea EUDAMED
Vitrea Advanced Visualization GUDID
Generic name
Radiological PACS-dedicated management software
Model / reference
7.16.3.SU01
Primary DI / UDI-DI
00850025268370
Basic UDI-DI
0850025268VitreaAVES
Direct marketing DI
00850025268370
FDA product code
LLZ, JAK, LMD
EMDN code
Z110603 Picture archiving and communication systems
GMDN term
Radiological PACS-dedicated management software
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.2050, 892.1750, 892.2020
Special device type
Software
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000020013
Authorised representative
MDSS GmbH DE-AR-000005430

Similar devices in this category

Other devices filed under PICTURE ARCHIVING AND COMMUNICATION SYSTEMS.

Other devices from Canon Medical Informatics, Inc.

See all devices from Canon Medical Informatics, Inc. →

Properties

  • Measuring function
  • Lot / batch number
  • Manufacturing date
Other properties (22, all answered No)