Vitrea
by Canon Medical Informatics, Inc. 9 variants
Part of a family of 10 devices: see the family page
Ref 7.16.3.SU01
Vitrea (7.16.3.SU01) is a device classified as Class IIa in the EU and Class II in the US made by Canon Medical Informatics, Inc., registered in EUDAMED on 20 Sep 2023 (Basic UDI-DI 0850025268VitreaAVES), cleared under FDA 510(k) K223261 on 13 Jul 2023 (18 earlier submissions) and listed in FDA GUDID since 24 Sep 2025 (UDI-DI 00850025268370), withdrawn (EUDAMED), active (FDA 510(k)) as of 24 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number00850025268370 | Date24 Sep 2025 | StatusListed |
| European Union | CE/MDR EUDAMED | Number0850025268VitreaAVES 00850025268370 | Date20 Sep 2023 | StatusWithdrawn |
| United States | FDA 510(k)SESE GUDID | NumberK223261 | Date13 Jul 2023 | StatusActive |
Official records
- EUDAMED public site 0850025268VitreaAVES
- AccessGUDID record 00850025268370
- FDA 510(k) database K223261
- FDA 510(k) database K222662
- FDA 510(k) database K181247
- FDA 510(k) database K182230
- FDA 510(k) database K172855
- FDA 510(k) database K161157
- FDA 510(k) database K160150
- FDA 510(k) database K151283
- FDA 510(k) database K151919
- FDA 510(k) database K150104
Across registries
- EUDAMED Basic UDI-DI 0850025268VitreaAVES registered 20 Sep 2023 Withdrawn
- FDA 510(k) K223261 decided 13 Jul 2023 Active
- FDA GUDID UDI-DI 00850025268370 listed 24 Sep 2025 Listed
Recalls
-
- Terminated Z-0169-2014
Vital Images, Inc. has found an issue in VitreaCore software though internal testing. There is a potential for incorrect and possibly reversed image orientation for certain snapshots taken in VitreaCore software versions 6.0, 6.1, 6.2, 6.3 (except 6.3.1), 6.4 (except 6.4.4 and 6.4.5), as well as their upgrades, and 6.5.
-
- Terminated Z-1181-2013
Vital Images, Inc. (Vital Images) received one report about potential user confusion when viewing a brain perfusion scan on Vitrea CT Brain Perfusion 2D when the scan was performed using a wide coverage shuttle acquisition technique. This may result in patient treatment delays, misdiagnosis or mistreatment.
-
- Terminated Z-1144-2013
Vital Images has made a decision to perform a field correction to the Vitrea CT Multi-Chamber Cardiac Functional Analysis application. Vital Images has identified a defect in which numerical values may be incorrect in the Results Table under the Cardiac Analysis portion of the user interface.
-
- Terminated Z-0186-2013
Vital Images has found two potential errors in calcium score values in restored snapshots of studies generated through use of Vitrea or Vitrea Enterprise Suite. This issue affects Version 3.1 of Vitrea fX; Version 5.2 of Vitrea; Versions 6.0, 6.1 and 6.2 of Vitrea and Vitrea fX; and Versions 1.3, 6.0, 6.1 and 6.2 of Vitrea Enterprise Suite; and all updates to those versions.
-
- Terminated Z-0388-2012
Vital Images has found two issues that may display incorrect Standard Update Values (SUV) when viewing certain PET/CT images. This issue affects the VitreaCore PET/CT feature for Vitrea Enterprise Suite 1.2, 1.3, 6.0, 6.1, including all updates to those versions.
-
- Terminated Z-1021-2011
There is a potential alignment error of fused PET/CT images in the Vitrea Core component of Vitrea Enterprise Suite 1.2 and 1.3. The error occurs during panning of the fused PET/CT images. Because the PET data has a larger voxel size than the CT data, it is possible to pan the CT image in more frequent, smaller steps than the PET image, so that the fused PET image does not move until the CT data
-
- Terminated Z-0520-2008
Standard Uptake Values (SUV) display/update problems; in the way Standard Uptake Values (SUV) are displayed in 3D/MPR views. The problem arises when a user draws a selected region of interest in order to calculate the SUV statistics of the region. If the user then changes the slice shown by scrolling through additional slices, the original SUV measurements will remain on the screen and do not up
Timeline
- Cleared FDA 510(k) K151283
- Cleared FDA 510(k) K160150
- Cleared FDA 510(k) K161157
- Cleared FDA 510(k) K172855
- Cleared FDA 510(k) K182230
- Cleared FDA 510(k) K181247
- Cleared FDA 510(k) K222662
- Cleared FDA 510(k) K223261
- Registered EUDAMED 0850025268VitreaAVES
- Listed FDA GUDID 00850025268370
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Vitrea EUDAMEDVitrea Advanced Visualization GUDID
- Generic name
- Radiological PACS-dedicated management software
- Model / reference
- 7.16.3.SU01
- Primary DI / UDI-DI
- 00850025268370
- Basic UDI-DI
- 0850025268VitreaAVES
- Direct marketing DI
- 00850025268370
- 510(k) Number
- FDA product code
- LLZ, JAK, LMD
- EMDN code
- Z110603 Picture archiving and communication systems
- GMDN term
- Radiological PACS-dedicated management software
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.2050, 892.1750, 892.2020
- Special device type
- Software
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000020013
- Authorised representative
- MDSS GmbH DE-AR-000005430
Similar devices in this category
Other devices filed under PICTURE ARCHIVING AND COMMUNICATION SYSTEMS.
- Visage Ease Pro 2.2 by Visage Imaging, Inc.
- Merge Universal Viewer 100-00001-01 by Merge Healthcare Incorporated
- Velocity Velocity 4.3 by Varian Medical Systems, Inc.
- IntelliSpace Cardiovascular 9 830089 by Philips Medical Systems Nederland B.V.
- ViewPoint 6 5896732 by GE Healthcare GmbH
- TOMTEC-ARENA TTA2 by Philips Ultrasound LLC
- Synapse Radiology PACS Synapse Radiology PACS Software License by FUJIFILM Healthcare Americas Corporation
- IntelePACS N/A by Intelerad Medical Systems Incorporated
- Universal Viewer v8 K2049DE by GE Healthcare
- Aycan Mobile by AYCAN DIGITALSYSTEME GMBH