Vitrea 7.3.2
by Canon Medical Informatics, Inc.
Vitrea 7.3.2 is a radiological PACS-dedicated management software (FDA Class II) made by Canon Medical Informatics, Inc., cleared under FDA 510(k) K161157 on 3 Nov 2016 (17 earlier submissions) and listed in FDA GUDID since 22 Dec 2016 (UDI-DI 00853866003216), active as of 22 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00853866003216 | Date22 Dec 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK161157 | Date3 Nov 2016 | StatusActive |
Official records
- AccessGUDID record 00853866003216
- FDA 510(k) database K161157
- FDA 510(k) database K161419
- FDA 510(k) database K160150
- FDA 510(k) database K151283
- FDA 510(k) database K151919
- FDA 510(k) database K151115
- FDA 510(k) database K150104
- FDA 510(k) database K150258
- FDA 510(k) database K143079
- FDA 510(k) database K141302
From the FDA record
- Device description
- Vitrea® software is an advanced visualization solution from Vital that creates 2D, 3D, and 4D images of human anatomy from image data from multiple modalities. With this tool, physicians can easily navigate within these images to better understand disease conditions. Vitrea addresses specialists’ needs through various software options for cardiac, colon, vessel probe, and other applications. In addition, Vitrea software utilizes an intuitive clinical workflow and automatic settings to improve speed and simplicity.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K161157 decided 3 Nov 2016 Active
- FDA GUDID UDI-DI 00853866003216 listed 22 Dec 2016 Listed
Recalls
-
- Terminated Z-0169-2014
Vital Images, Inc. has found an issue in VitreaCore software though internal testing. There is a potential for incorrect and possibly reversed image orientation for certain snapshots taken in VitreaCore software versions 6.0, 6.1, 6.2, 6.3 (except 6.3.1), 6.4 (except 6.4.4 and 6.4.5), as well as their upgrades, and 6.5.
-
- Terminated Z-1144-2013
Vital Images has made a decision to perform a field correction to the Vitrea CT Multi-Chamber Cardiac Functional Analysis application. Vital Images has identified a defect in which numerical values may be incorrect in the Results Table under the Cardiac Analysis portion of the user interface.
-
- Terminated Z-1181-2013
Vital Images, Inc. (Vital Images) received one report about potential user confusion when viewing a brain perfusion scan on Vitrea CT Brain Perfusion 2D when the scan was performed using a wide coverage shuttle acquisition technique. This may result in patient treatment delays, misdiagnosis or mistreatment.
-
- Terminated Z-0186-2013
Vital Images has found two potential errors in calcium score values in restored snapshots of studies generated through use of Vitrea or Vitrea Enterprise Suite. This issue affects Version 3.1 of Vitrea fX; Version 5.2 of Vitrea; Versions 6.0, 6.1 and 6.2 of Vitrea and Vitrea fX; and Versions 1.3, 6.0, 6.1 and 6.2 of Vitrea Enterprise Suite; and all updates to those versions.
-
- Terminated Z-0388-2012
Vital Images has found two issues that may display incorrect Standard Update Values (SUV) when viewing certain PET/CT images. This issue affects the VitreaCore PET/CT feature for Vitrea Enterprise Suite 1.2, 1.3, 6.0, 6.1, including all updates to those versions.
-
- Terminated Z-0797-2011
Vital Images Inc., reported that a software defect exists with Vitrea fX 2.1, 3.0 and 3.1 CT Brain Analysis whereby the annotated numeric ROI values on a batched perfusion map are incorrect when created using the auto batching function (from the right click menu) with the auto ROI templates enabled.
-
- Terminated Z-1021-2011
There is a potential alignment error of fused PET/CT images in the Vitrea Core component of Vitrea Enterprise Suite 1.2 and 1.3. The error occurs during panning of the fused PET/CT images. Because the PET data has a larger voxel size than the CT data, it is possible to pan the CT image in more frequent, smaller steps than the PET image, so that the fused PET image does not move until the CT data
-
- Terminated Z-0520-2008
Standard Uptake Values (SUV) display/update problems; in the way Standard Uptake Values (SUV) are displayed in 3D/MPR views. The problem arises when a user draws a selected region of interest in order to calculate the SUV statistics of the region. If the user then changes the slice shown by scrolling through additional slices, the original SUV measurements will remain on the screen and do not up
Timeline
- Cleared FDA 510(k) K143079
- Cleared FDA 510(k) K150258
- Cleared FDA 510(k) K150104
- Cleared FDA 510(k) K151115
- Cleared FDA 510(k) K151919
- Cleared FDA 510(k) K151283
- Cleared FDA 510(k) K160150
- Cleared FDA 510(k) K161419
- Cleared FDA 510(k) K161157
- Listed FDA GUDID 00853866003216
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Vitrea
- Generic name
- Radiological PACS-dedicated management software
- Model / reference
- 7.3.2
- Primary DI / UDI-DI
- 00853866003216
- 510(k) Number
- FDA product code
- JAK, LLZ
- GMDN term
- Radiological PACS-dedicated management software
- Device class
- Class II
- Regulation number
- 892.1750, 892.2050
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Radiological PACS software.
- McKesson Radiology 12.3 by Change Healthcare Canada Company
- INFINITT Cardiology PACS by INFINITT Healthcare Co., Ltd.
- Change Healthcare Radiology Solutions 14.0 by Change Healthcare Canada Company
- INFINITT RT PACS by INFINITT Healthcare Co., Ltd.
- Visage Ease Pro 2.2 by Visage Imaging, Inc.
- Vitrea Software Package VSTP-002A by CANON INC.
- Sidexis 4 6773258 by SIRONA Dental Systems GmbH
- ContourProtégéAI - CT Thorax 1.0 by MIM SOFTWARE INC.