Vitrea Advanced Visualization 7.10
by Canon Medical Informatics, Inc.
Vitrea Advanced Visualization 7.10 is a radiological PACS-dedicated management software (FDA Class II) made by Canon Medical Informatics, Inc., cleared under FDA 510(k) K182230 on 7 Sep 2018 (15 earlier submissions) and listed in FDA GUDID since 19 Nov 2018 (UDI-DI 00853866003414), active as of 22 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00853866003414 | Date19 Nov 2018 | StatusListed |
| United States | FDA 510(k)SESE | NumberK182230 | Date7 Sep 2018 | StatusActive |
Official records
- AccessGUDID record 00853866003414
- FDA 510(k) database K182230
- FDA 510(k) database K172855
- FDA 510(k) database K161157
- FDA 510(k) database K160150
- FDA 510(k) database K151283
- FDA 510(k) database K151919
- FDA 510(k) database K150104
- FDA 510(k) database K143079
- FDA 510(k) database K141302
- FDA 510(k) database K140395
From the FDA record
- Device description
- The Vitrea Advanced Visualization software is a medical diagnostic system that allows the processing, review, analysis, communication, and media interchange of multi-dimensional digital images acquired from a variety of imaging devices. The Vitrea Advanced Visualization system provides multi-dimensional visualization of digital images to aid clinicians in their analysis of anatomy and pathology. The Vitrea Advanced Visualization user interface follows typical clinical workflow patterns to process, review, and analyze digital images, including: • Retrieve image data over the network via DICOM • Display of images in dedicated protocols which are automatically adapted based on exam type • Select images for closer examination from a gallery of 2D or 3D views • Interactively manipulate an image in real-time to visualize anatomy and pathology • Annotate, measure, and record selected views • Output selected views to standard film or paper printers, or post a report to an intranet web server or export views to another DICOM device • Retrieve reports that are archived on a Web server
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K182230 decided 7 Sep 2018 Active
- FDA GUDID UDI-DI 00853866003414 listed 19 Nov 2018 Listed
Recalls
-
- Terminated Z-0169-2014
Vital Images, Inc. has found an issue in VitreaCore software though internal testing. There is a potential for incorrect and possibly reversed image orientation for certain snapshots taken in VitreaCore software versions 6.0, 6.1, 6.2, 6.3 (except 6.3.1), 6.4 (except 6.4.4 and 6.4.5), as well as their upgrades, and 6.5.
-
- Terminated Z-1144-2013
Vital Images has made a decision to perform a field correction to the Vitrea CT Multi-Chamber Cardiac Functional Analysis application. Vital Images has identified a defect in which numerical values may be incorrect in the Results Table under the Cardiac Analysis portion of the user interface.
-
- Terminated Z-1181-2013
Vital Images, Inc. (Vital Images) received one report about potential user confusion when viewing a brain perfusion scan on Vitrea CT Brain Perfusion 2D when the scan was performed using a wide coverage shuttle acquisition technique. This may result in patient treatment delays, misdiagnosis or mistreatment.
-
- Terminated Z-0186-2013
Vital Images has found two potential errors in calcium score values in restored snapshots of studies generated through use of Vitrea or Vitrea Enterprise Suite. This issue affects Version 3.1 of Vitrea fX; Version 5.2 of Vitrea; Versions 6.0, 6.1 and 6.2 of Vitrea and Vitrea fX; and Versions 1.3, 6.0, 6.1 and 6.2 of Vitrea Enterprise Suite; and all updates to those versions.
-
- Terminated Z-0388-2012
Vital Images has found two issues that may display incorrect Standard Update Values (SUV) when viewing certain PET/CT images. This issue affects the VitreaCore PET/CT feature for Vitrea Enterprise Suite 1.2, 1.3, 6.0, 6.1, including all updates to those versions.
-
- Terminated Z-1021-2011
There is a potential alignment error of fused PET/CT images in the Vitrea Core component of Vitrea Enterprise Suite 1.2 and 1.3. The error occurs during panning of the fused PET/CT images. Because the PET data has a larger voxel size than the CT data, it is possible to pan the CT image in more frequent, smaller steps than the PET image, so that the fused PET image does not move until the CT data
-
- Terminated Z-0520-2008
Standard Uptake Values (SUV) display/update problems; in the way Standard Uptake Values (SUV) are displayed in 3D/MPR views. The problem arises when a user draws a selected region of interest in order to calculate the SUV statistics of the region. If the user then changes the slice shown by scrolling through additional slices, the original SUV measurements will remain on the screen and do not up
Timeline
- Cleared FDA 510(k) K141302
- Cleared FDA 510(k) K143079
- Cleared FDA 510(k) K150104
- Cleared FDA 510(k) K151919
- Cleared FDA 510(k) K151283
- Cleared FDA 510(k) K160150
- Cleared FDA 510(k) K161157
- Cleared FDA 510(k) K172855
- Cleared FDA 510(k) K182230
- Listed FDA GUDID 00853866003414
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Vitrea Advanced Visualization
- Generic name
- Radiological PACS-dedicated management software
- Model / reference
- 7.10
- Primary DI / UDI-DI
- 00853866003414
- 510(k) Number
- FDA product code
- JAK, LLZ
- GMDN term
- Radiological PACS-dedicated management software
- Device class
- Class II
- Regulation number
- 892.1750, 892.2050
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Radiological PACS software.
- ImagePilot V1.95 by KONICA MINOLTA, INC.
- McKesson Radiology 12.2.2 by Change Healthcare Canada Company
- ContourProtégéAI 1.3 by MIM SOFTWARE INC.
- MIM 7.4 by MIM SOFTWARE INC.
- INFINITT ULite by INFINITT Healthcare Co., Ltd.
- Change Healthcare Enterprise Viewer 2.1.1 by Change Healthcare Canada Company
- INFINITT PACS 7.0 by INFINITT Healthcare Co., Ltd.
- eUnity-1 by Mach7 Technologies Canada Inc
- syngo.plaza 11293724 by Siemens Healthcare GmbH