Microgenics Corporation

United States·US-MF-000030375

Last updated September 17, 2026

Information

Country
United States
Address
46500 , Kato Road, Fremont, United States
Website
www.thermofisher.com/diagnostics

This website did not respond in time when we last checked. Last checked 2026-09-18.

LinkedIn
—
Facebook
—
Phone
001-510-979-5000
PRRC Contact
Mark Brandes
EUDAMED SRN
US-MF-000030375
FDA FEI Number
3010939897
DUNS Number
—

Catalogue (706)

Page 1 of 15
DeviceModel / ReferenceRegistriesClassStatus
ARCHITECT Cannabinoid 100 Calibrator 3L41-03
EUDAMED
IVD GeneralActive
ARCHITECT Cannabinoid Reagent Kit 3L41-20
EUDAMED
IVD GeneralActive
ARCHITECT Opiates 300 Calibrator 3L34-02
EUDAMED
IVD GeneralActive
ARCHITECT DOA MC Negative Calibrator 3L43-05
EUDAMED
IVD GeneralActive
ARCHITECT Cannabinoid 125 Control 3L41-16
EUDAMED
IVD GeneralActive
ARCHITECT Cocaine Reagent Kit 3L40-20
EUDAMED
IVD GeneralActive
CEDIA Gentamicin II Assay (125 tests) 09086137190
EUDAMED
IVD GeneralActive
DRI Oxycodone Control Set 300 05178550190
EUDAMED
IVD GeneralActive
ARCHITECT Ethanol 300 Control 3L36-12
EUDAMED
IVD GeneralActive
ARCHITECT Tox Controls 6L36-10
EUDAMED
IVD GeneralActive
ARCHITECT Tox Calibrators 1 6L36-01
EUDAMED
IVD GeneralActive
ARCHITECT Tox Negative Calibator 6L36-05
EUDAMED
IVD GeneralActive
Alinity c Amphetamine/Methamphetamine 09P4520
EUDAMED
IVD GeneralActive
ARCHITECT DOA MC I Calibrator 4 3L43-04
EUDAMED
IVD GeneralActive
ARCHITECT Valproic Acid 1E13-20
EUDAMED
IVD GeneralActive
ARCHITECT Propoxyphene 6L97-20
EUDAMED
IVD GeneralActive
ARCHITECT Tobramycin Reagent 7F93-20
EUDAMED
IVD GeneralActive
ARCHITECT Ecstasy 750 Calibrator 3L42-03
EUDAMED
IVD GeneralActive
ARCHITECT Ethanol 50 Control 3L36-10
EUDAMED
IVD GeneralActive
DRI Oxycodone Control Set 100 05178568190
EUDAMED
IVD GeneralActive
ARCHITECT Theophylline 05P06-21
EUDAMED
IVD GeneralActive
ARCHITECT Tricyclic Antidepressants 6L28-20
EUDAMED
IVD GeneralActive
ARCHITECT DOA MC I Calibrator 2 3L43-02
EUDAMED
IVD GeneralActive
ARCHITECT Serum Benzodiazepines 6L30-20
EUDAMED
IVD GeneralActive
ARCHITECT Ethanol Reagent Kit 3L36-20
EUDAMED
IVD GeneralActive
ARCHITECT Digoxin Calibrator 1E06-02
EUDAMED
IVD GeneralActive
ARCHITECT Phenobarbital 05P07-21
EUDAMED
IVD GeneralActive
ARCHITECT Opiates 1000 Calibrator 3L34-04
EUDAMED
IVD GeneralActive
ARCHITECT TDM Multiconstituent Calibrator 5P04-01
EUDAMED
IVD GeneralActive
ARCHITECT Ecstasy 500 Calibrator 3L42-02
EUDAMED
IVD GeneralActive
ARCHITECT Cannabinoid 200 Calibrator 3L41-04
EUDAMED
IVD GeneralActive
ARCHITECT Ethanol Negative Calibrator 3L36-01
EUDAMED
IVD GeneralActive
ARCHITECT Amphetamine/Methamphetamine 3L37-20
EUDAMED
IVD GeneralActive
ARCHITECT DOA MC I Control 3L43-10
EUDAMED
IVD GeneralActive
ARCHITECT Phenytoin 05P08-21
EUDAMED
IVD GeneralActive
ARCHITECT Opiates 150 Calibrator 3L34-01
EUDAMED
IVD GeneralActive
ARCHITECT Opiates Reagent Kit 3L34-20
EUDAMED
IVD GeneralActive
ARCHITECT Ecstasy Reagent 3L42-20
EUDAMED
IVD GeneralActive
ARCHITECT Cannabinoid 60 Control 3L41-12
EUDAMED
IVD GeneralActive
ARCHITECT DOA MC I Calibrator 3 3L43-03
EUDAMED
IVD GeneralActive
ARCHITECT Tox Calibrators 3 6L36-03
EUDAMED
IVD GeneralActive
ARCHITECT DOA MC I Calibrator 1 3L43-01
EUDAMED
IVD GeneralActive
ARCHITECT Benzodiazepines 3L39-20
EUDAMED
IVD GeneralActive
ARCHITECT Cannabinoid 20 Calibrator 3L41-01
EUDAMED
IVD GeneralActive
ARCHITECT Tox Calibrators 2 6L36-02
EUDAMED
IVD GeneralActive
ARCHITECT Carbamazepine 05P05-21
EUDAMED
IVD GeneralActive
ARCHITECT Ecstasy 250 Calibrator 3L42-01
EUDAMED
IVD GeneralActive
ARCHITECT DOA MC 3 Controls 4P51-10
EUDAMED
IVD GeneralActive
DRI Oxycodone Calibrator 0 05201284190
EUDAMED
IVD GeneralActive
ARCHITECT Phencyclidine 6L96-20
EUDAMED
IVD GeneralActive

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (14)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Oct 1, 2025Z-0415-2026—open, classified

The firm received complaints from customers reporting vial-to-vial variability when using the control with high sensitivity Troponin I assays. This defect may lead to as delay in patient results for hs Troponin I assays.

Jan 20, 2022Z-1284-2022—open, classified

Due to QMS Tacrolimus Calibrator recovering between 82 to 94% of their target values, resulting in over-quantitation in tacrolimus patient result values when used with the QMS Tacrolimus Immunoassay.

Aug 15, 2016Z-0008-2017—terminated

A reagent stability issue (still under investigation) causes less separation in the calibration curve, which affects results across the entire range. For controls, maximum bias of +/- 35% for low levels, +/- 33% for mid-range levels, and +/- 47% for high levels is observed. Bias in patient samples ranges from -15.7% to +5.2% with an average bias of -5.6% when comparing the QMS everolimus assay to an everolimus LC-MS reference method. Patient samples across the measuring range sub-therapeutic, therapeutic, and supra-therapeutic could be affected.

Jul 25, 2016Z-2884-2016—terminated

Some lots of DRI Salicylate Serum Tox Assay negative patient samples are recovering higher than the product sensitivity claim of 4.4 mg/dL.

Oct 20, 2014Z-0501-2015—terminated

MAS CardioImmune XL, level 1 (lot CXL16011), is showing vial-to-vial variation for the analytes Creatine Kinase-MB (CK-MB) and B-Type Natriuretic Peptide-32 (BNP-32).

Dec 2, 2013Z-1930-2014—terminated

The constituent, Inhibin A, was removed from MAS Omni IMMUNE and MAS Omni IMMUNE PRO controls; however the package insert was not updated to reflect the change.

Dec 2, 2013Z-1929-2014—terminated

The constituent, Inhibin A, was removed from MAS Omni IMMUNE and MAS Omni IMMUNE PRO controls; however the package insert was not updated to reflect the change.

Oct 16, 2013Z-0513-2014—terminated

Microgenics Corp., part of Thermo Fisher Scientific, is recalling CEDIA Tobramycin II Assay (Lot Number: 60169764) due to calibration stability problem relating to two complaints received.

Jul 23, 2013Z-2267-2013—terminated

Surveillance of reagent stability for specific lots of DRI Cocaine Metabolite Reagent show an unexpected decreasing change in the reaction rate, indicating a faster than expected reagent degradation.

May 13, 2013Z-1563-2013—terminated

It has been confirmed from in-house testing that Direct Bilirubin (DBIL), and Total Bilirubin (TBIL) claimed in Thermo Scientific MAS Bilirubin Systems are displaying reduced stability.

Aug 20, 2012Z-0379-2013—terminated

In house testing confirmed that CK-MS and Insulin claimed in both Omni IMMUNE and Omni IMMUNE PRO products are displaying reduced stability.

Dec 14, 2011Z-0637-2012—terminated

Low measurements of Troponin I in the MAS CardioImmune XL Control which were outside the published control ranges.

Nov 11, 2011Z-0773-2012—terminated

Reports that third party control material for 4 lots of Tobramycin Calibrators that are recovering low and outside of the published range.

Jun 8, 2011Z-0297-2012—terminated

Complaint from the sole distributor that the third party control material is recovering high, and outside the published range.