Skip to content

3M™ Ranger™ 24240

by 3M Company

3M Ranger 24240 is a conduction blood/fluid warmer set (FDA Class II; FDA product code BSB, Warmer, blood, non-electromagnetic radiation) made by 3M Company, cleared under FDA 510(k) K973741 on 30 Apr 1998 and listed in FDA GUDID since 21 Jun 2021 (UDI-DI 10707387805002), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K973741

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10707387805002 UDI-DI Date21 Jun 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK973741 Date30 Apr 1998DecidedStatusActive

Official records

From the FDA record

Device description
3M™ Ranger™ Blood/Fluid Warming Standard Flow Set, 24240, 10/Case
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K973741 decided 30 Apr 1998 Active
  • FDA GUDID UDI-DI 10707387805002 listed 21 Jun 2021 Listed

Recalls

3 recalls · 1 ongoing · FDA

    • Ongoing Z-2483-2025 FDA Class I initiated 10 Apr 2025

    Field action to clarify the flow rates and inlet fluid temperatures, along with location of the outlet temperature for Ranger Blood/Fluid Warming High Flow Sets.

  • 2 recalls, same reason

    • Terminated Z-1183-2007 FDA Unclassified (pre-2012) initiated 26 Jun 2007 on shared 510(k) K973741
    • Terminated Z-1184-2007 FDA Unclassified (pre-2012) initiated 26 Jun 2007 on shared 510(k) K973741

    Incomplete seal on the product pouch; with the seal incomplete, the sterility of the product inside the pouch cannot be guaranteed.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K973741
  2. Recall initiated FDA recalls Z-1183-2007
  3. Recall initiated FDA recalls Z-1184-2007
  4. Listed FDA GUDID 10707387805002
  5. Recall initiated FDA recalls Z-2483-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
3M™ Ranger™
Generic name
Conduction blood/fluid warmer set
Model / Ref / Catalog
24240
Primary DI / UDI-DI
10707387805002
FDA product code
BSB
GMDN term
Conduction blood/fluid warmer set
Device class
Class II
Regulation number
864.9205
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code BSB (Warmer, blood, non-electromagnetic radiation).

Other devices from 3M Company

See all devices from 3M Company →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)