7C2 Transducer 11268277
by Siemens Medical Solutions USA, Inc.
Ref 11268277Model MDR_07_IIA_IQH_BTS LB A_ACDV_7C2_11268277
7C2 Transducer 11268277 is a device classified as Class IIa in the EU and Class II in the US made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 8 Sep 2026 (Basic UDI-DI 0405686902414VG), cleared under FDA 510(k) K232617 on 26 Sep 2023 (2 earlier submissions) and listed in FDA GUDID since 20 Feb 2018 (UDI-DI 04056869051956), active as of 23 Oct 2026.
Active
Valid until
No date given
FDA recalls
5 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686902414VG 04056869051956 | Date8 Sep 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK232617 | Date26 Sep 2023 | StatusActive |
| United States | GUDID listing GUDID | Number04056869051956 | Date20 Feb 2018 | StatusListed |
Official records
- EUDAMED public site 0405686902414VG
- AccessGUDID record 04056869051956
- FDA 510(k) database K232617
- FDA 510(k) database K201130
- FDA 510(k) database K180039
Across registries
- EUDAMED Basic UDI-DI 0405686902414VG registered 8 Sep 2026 Active
- FDA 510(k) K232617 decided 26 Sep 2023 Active
- FDA GUDID UDI-DI 04056869051956 listed 20 Feb 2018 Listed
Recalls
-
- Ongoing Z-3217-2024
- Ongoing Z-3215-2024
If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliters using multiplier 100 instead of 1000, resulting values 10x smaller than actual, which could contribute misdiagnosis or negatively influence patient management
-
- Ongoing Z-1599-2024
- Ongoing Z-1601-2024
On ultrasound systems, when Cardiac DICOM SR feature is configured to display either minimum or maximum measured value, and multiple cardiac region measurements are made, and results are exported into the SR feature, then The SR viewer will display the LAST measured value, not min or max, which could contribute to patient condition misdiagnosis or negatively influence patient management decisions.
-
- Ongoing Z-0748-2022
The clip store function in the ultrasound imaging system does not work when the system has a disk full error. This could cause a delay in treatment if the ultrasound system is unable to save clips as study documentation during a high risk procedure, such as a stress echo exam.
-
- Terminated Z-2471-2021
Due to intermittent failures of the power supply in the ultrasound system which renders it inoperable.
Timeline
- Listed FDA GUDID 04056869051956
- Cleared FDA 510(k) K201130
- Recall initiated FDA recalls Z-2471-2021
- Recall initiated FDA recalls Z-0748-2022
- Cleared FDA 510(k) K232617
- Recall initiated FDA recalls Z-1599-2024
- Recall initiated FDA recalls Z-1601-2024
- Recall initiated FDA recalls Z-3217-2024
- Recall initiated FDA recalls Z-3215-2024
- Registered EUDAMED 0405686902414VG
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- 7C2 Transducer
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Device name
- MDR_07_IIA_IQH_BTS Lb A_ACDV_7C2_11268277
- Model / reference
- 11268277, MDR_07_IIA_IQH_BTS LB A_ACDV_7C2_11268277
- Primary DI / UDI-DI
- 04056869051956
- Basic UDI-DI
- 0405686902414VG
- FDA product code
- ITX
- EMDN code
- Z110402010201 Curvilinear transcutaneous two–dimensional ultrasound probes (convex–array)
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under CURVILINEAR TRANSCUTANEOUS TWO–DIMENSIONAL ULTRASOUND PROBES (CONVEX–ARRAY).
- C10-3 P23117-20A by Fujifilm Sonosite, Inc.
- C253A 04573596214510 by FUJIFILM CORPORATION
- C1-6VN-D by GE HEALTHCARE JAPAN CORPORATION
- Vscan Air CL GP000160 by Ge Vingmed Ultrasound
- C60xf/5-2 MHz P18024-21 by Fujifilm Sonosite, Inc.
- CA621 9600155000 by Esaote S.p.A.
- 8C-RS H40402LS by GE Healthcare Japan Corporation
- 9C2 Transducer 9002 by Bk Medical ApS
- GP-C01 99-7903-00 by Interson Corporation
- C25P 04573596211366 by FUJIFILM CORPORATION