ABL800 Flex
510(k) K041874
ABL800 Flex is a medical device (FDA Class II; FDA product code CHL, Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph) made by Radiometer Medical ApS, cleared under FDA 510(k) K041874 on 8 Oct 2004, active as of 9 Oct 2026. 21 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
4 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK041874 | Date8 Oct 2004 | StatusActive |
Official records
- FDA 510(k) database K041874
From the FDA record
- Received by the FDA
- 12 Jul 2004
- FDA decision
- 8 Oct 2004 (Substantially Equivalent)
- FDA review time
- 88 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-0190-2027
In vitro diagnostic analyzer had a risk of potentially inaccurate results requiring changes to instructions for use and: 1) Sample types, including whole blood samples no longer suitable for testing FHbF and ctBil, 2) Reportable ranges for some parameters, 3) Analyzer configuration, and 4) limitations and warnings.
-
- Ongoing Z-2426-2024
Issue with analyzer when the pH of the calibration solution decreases during the in-use period potentially because of bacterial growth in the calibration solution bottles. This may result in a probability of reporting biased out-of-specification pH results on blood samples.
-
- Ongoing Z-1321-2022
There is a potential for sporadic incidents of positive and negative biases for analyzer systems configured with cNa+, cCa+, and cK+.
-
- Ongoing Z-1836-2020
Through internal investigation is has been determined that an incorrect component was used within the power supply. The incorrect component may cause a short circuit within the power supply resulting in a delay in treatment. The delay could result in a range of risk from cyanosis and low blood pressure to cardiac arrhythmias and severe impairment of cardiac function.
-
- Terminated Z-2494-2020
- Terminated Z-2493-2020
Potential risk of patient mix-up on analyzers due to software issues.
-
- Terminated Z-1684-2020
Analyzer's barcode reader misinterprets the contents of barcode label used for entering patient ID or accession number. The issue is related to barcode types not using a check digit. This could result in patient mixup or loss of sample resulting in delayed medical treatment
-
- Terminated Z-0682-2019
The analyzer software may cause a mis-match of patient demographics and test results when a certain sequence of events occur.
-
- Terminated Z-0231-2018
Due to misinterpretation of the barcode by the scanner, when the registration receipt barcode is scanned by the analyzer , a result from a different patient will be printed or displayed on the analyzer.
-
- Terminated Z-1463-2017
Reports that the sample type "cord blood" has been changed into the two sample types "cord blood arterial" and "cord blood venous.
-
- Terminated Z-1075-2014
RADIOMETER has become aware that some D788 pCO2 membranes can cause biased measurement results on patient results as well as QC results.
-
- Terminated Z-2162-2012
- Terminated Z-2163-2012
A customer has reported an error on an ABL8xx configured to a Hospital Information System using the data transfer protocol HL7 version 2.5. If the instrument transmits results to a HIS system and the connection is broken the results are queued for later transmission. If the ABL and HIS system are configured with HL7 2.5, any results in the queue will be mixed up when the instrument transmits t
-
- Terminated Z-1554-2009
When removing the waste bottle from the analyzer waste material may leak both from the analyzer and from the waste bottle.
-
- Terminated Z-1654-2008
Reported calibration errors are not displayed on the analyzers parameter bar screen or on the patient results when the calibration number is between 32768 - 65535 and 98303 - 131070. This may cause the operator to perform measurements and obtain questionable results.
-
- Terminated Z-0038-2008
Tube may break. The firm discovered that the yellowish/white tubes used in their blood gas analyzers (ABL800 Flex Series) were manufactured incorrectly. These tubes have the potential to break off at the black plastic connectors. The breakage may occur during the installation of the tubes or after a short time in use.
-
- Terminated Z-1095-2007
Software anomaly. Protein removing program incorporated in the operating software for Versions: V3.833 and V5.24, of the ABL700 and ABL800 Blood Gas Analyzers, may allow for protein build up on the electrode membranes of blood gas analyzers. This condition can influence analyzer results. When the protein removal program is run too frequently, more than once a week, or when running the protein rem
-
- Terminated Z-1325-06
ABL800 Series Blood Gas Analyzer became inoperable when the 'restore default setup' button was touched.
-
- Terminated Z-1387-06
Under certain circumstances, the ABL 700 &800 Series Blood Gas Analyzers may experience leakage current into the measuring system. Consequently, the analyzers intermittently provide incorrect (too low) result values for Calcium (Ca) and Sodium (Na).
-
- Terminated Z-1324-06
Reference electrodes for the firm's ABL 700/800 Blood Gas Analyzers are oversized and will not fit into the instrument.
-
- Terminated Z-1319-06
The recalled membranes cause the status value of the pH and electrolyte electrodes to be offset causing readings outside of the acceptable range.
-
- Terminated Z-1318-06
Software defect. pO2 and pCO2 sample test results run on the firm's ABL700/800 Series Blood Gas Analyzers are not being properly flagged during the sample calibration phase.
Timeline
- Recall initiated FDA recalls Z-1463-2017
- Recall initiated FDA recalls Z-0231-2018
- Recall initiated FDA recalls Z-0682-2019
- Recall initiated FDA recalls Z-1836-2020
- Recall initiated FDA recalls Z-1684-2020
- Recall initiated FDA recalls Z-2494-2020
- Recall initiated FDA recalls Z-2493-2020
- Recall initiated FDA recalls Z-1321-2022
- Recall initiated FDA recalls Z-2426-2024
- Recall initiated FDA recalls Z-0190-2027
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- CHL
- Device class
- Class II
- Regulation
- 21 CFR Part 862.1120
- Advisory committee
- Clinical Chemistry
- FDA decision
- SESE Substantially Equivalent
Similar devices
Other devices filed under FDA product code CHL (Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph).
- BLOOD PH CAPILLARY TUBES, HEPARIN by Helps Products, Inc.
- AVL OPTI PH/BLOOD GAS ANALYZER by Avl Scientific Corp.
- DMI BLOD GAS ANALYZER/CARTRIDGE by Diamond Medical, Inc.
- STAT PAL SENSYR SYRINGE ASSEMBLY FOR USE W/STATPAL by Ppg Industries, Inc.
- CORNING 170 PH/BLOOD GAS ANALYZER by Corning Medical & Scientific
- ANALYZER: NOVA STAT PROFILE 1 QUA CON MAT: ELECT by NOVA BIOMEDICAL CORPORATION
- MONITOR, PATIENT, MODEL PM-20N by Cavitron Corp.
- BLOOD GAS ANALYSIS, STANDARDS CONTROLS by United Diagnostics, Inc.
- IRMA BLOOD ANALYSIS SYSTEM by Diametrics Medical, Ltd.
- GEM Premier 3000 iQM - BG HCT ELECT. GL - 600 Tests 00024360089 by INSTRUMENTATION LABORATORY COMPANY