ABL90 Flex Series
510(k) K092686
ABL90 Flex Series is a medical device (FDA Class II; FDA product code CEM, Electrode, Ion Specific, Potassium) made by Radiometer Medical ApS, cleared under FDA 510(k) K092686 on 6 Aug 2010, active as of 22 Oct 2026. 6 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
3 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK092686 | Date6 Aug 2010 | StatusActive |
Official records
- FDA 510(k) database K092686
From the FDA record
- Received by the FDA
- 2 Sep 2009
- FDA decision
- 6 Aug 2010 (Substantially Equivalent)
- FDA review time
- 338 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-1659-2025
ABL90 FLEX and ABL90 FLEX PLUS analyzers running with Radiometer Windows 10 versions RWIN10 1.0 and RWIN10 1.1 may unexpectedly freeze (the analyzer ceases to operate) during a sample measurement. The analyzer software includes a feature (watchdog) that detects a freeze and automatically restarts the software to continue operating the analyzer. However, even if a restart occurs, any sample being processed at that time will be lost, potential to lead to delay in test results.
-
- Ongoing Z-1858-2021
- Ongoing Z-1856-2021
Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed.
-
- Terminated Z-1760-2020
The firm received reports of occurrences where the barcode reader misinterpreted the contents of a locally printed barcode label used for entering patient ID or accession number into the analyzer in connection with a sample measurement. This could result is patient mixup and/or lost of sample, resulting in delayed medical treatment.
-
- Terminated Z-2139-2020
The analyzers fail on S7950 (Range +) QC measurements due to the hemolyzer cuvettes, a subcomponent of the optical system which measures ctHb and derivates. In a cuvette with light shunt, some of the received light has not been transmitted through the sample. This will lead to a perturbed and non-linear absorbance spectrum which results in measurement errors.
-
- Terminated Z-2320-2019
Software Security; The action is being initiated because of software security vulnerabilities with the firm's analyzer operating system, which may cause the device to shutdown or reboot resulting in delayed medical treatment.
-
- Terminated Z-1462-2017
Reports that the sample type "cord blood" has been changed into the two sample types "cord blood arterial" and "cord blood venous.
-
- Terminated Z-0816-2014
RADIOMETER become aware that if the ABL90 FLEX is tilted, this may potentially cause a negative bias on sodium (Na+) results.
-
- Terminated Z-2112-2011
Following the receipt of two (2) reported customer complaints, the firm determined that the current operating software for their ABL 90 Analyzer does not prevent the further use of the sensor cassette when there is the possibility of iron rich plaque build-up in the reference electrode. If the device operator/user ignores the error message and continues to obtain biased measuring results using the
-
- Terminated Z-1011-2011
Due to a software error, a patient mix up can occur on the ABL90. If a sample is pre-registered and the sample "fails" the next result will inherit the patient data from the previous result.
Timeline
- Recall initiated FDA recalls Z-1011-2011
- Recall initiated FDA recalls Z-2112-2011
- Recall initiated FDA recalls Z-0816-2014
- Recall initiated FDA recalls Z-1462-2017
- Recall initiated FDA recalls Z-2320-2019
- Recall initiated FDA recalls Z-2139-2020
- Recall initiated FDA recalls Z-1760-2020
- Recall initiated FDA recalls Z-1858-2021
- Recall initiated FDA recalls Z-1856-2021
- Recall initiated FDA recalls Z-1659-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- CEM
- Device class
- Class II
- Regulation
- 21 CFR Part 862.1600
- Advisory committee
- Clinical Chemistry
- FDA decision
- SESE Substantially Equivalent
Similar devices
Other devices filed under FDA product code CEM (Electrode, Ion Specific, Potassium).
- SmartLyte® Plus Electrolyte Analyzer Na+/K+/Cl-/Ca++/Li+ by DIAMOND DIAGNOSTICS Inc
- DIMENSION CLINICAL CHEMISTRY SYSTEM, MODEL XPAND by Dade Behring, Inc.
- CHEM PRO 1000 CHEMISTRY ANALYSIS by Sen Tech Medical Corp.
- REAGENT FOR DETERM. POTASSIUM/IN HUMAN by Diagnostic Solutions, Inc.
- ULTRA LYTE POTASSIUM REAGENT KIT by Ultra Quest Diagnostics, Inc.
- NOVA NA/K/CL/LI MODULE by NOVA BIOMEDICAL CORPORATION
- ACCELERATOR APS by Abbott Laboratories
- NOVA 11 NA/K/LI ANALYZER by NOVA BIOMEDICAL CORPORATION
- ULTRA LYTE ANALYZER I 100 by Ultra Quest Diagnostics, Inc.
- DUPONT ACA ION SELECTIVE ELECTRODE by E.I. Dupont DE Nemours & Co., Inc.