Skip to content

ABL90 FLEX

by Radiometer Medical ApS 5 variants

510(k) K122642

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Source FDA 510(k), synced 6 Oct 2026.

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK122642 Date26 Oct 2012ClearedStatusActive

Official records

From the FDA record

Received by the FDA
29 Aug 2012
FDA decision
26 Oct 2012 (Substantially Equivalent)
FDA review time
58 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K122642 (openFDA), as read on 6 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CHL
Device class
Class II
Regulation
21 CFR Part 862.1120
Advisory committee
Clinical Chemistry
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The ABL90 FLEX is an Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph device, designed for the precise analysis of arterial and venous blood samples. It measures key parameters such as partial pressures of carbon dioxide (Pco2) and oxygen (Po2), pH, and other blood chemistry metrics to assess acid-base balance, oxygenation status, and metabolic function in clinical settings.

This device is intended for use in clinical chemistry laboratories and critical care environments, providing rapid results within 35 seconds from a minimal sample volume of 65 µL. Supplied as a reusable medical instrument, it requires proper calibration and maintenance as outlined in its operator manual. The ABL90 FLEX adheres to FDA 510(k) clearance under Special Review (K122642) and is classified under device class 2 (862.1120). Sterility and regulatory compliance are ensured through manufacturer validation processes.

Similar devices

Other devices filed under FDA product code CHL (Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph).

Other devices from Radiometer Medical ApS

See all devices from Radiometer Medical ApS →