Skip to content

AccuSITE Needle Guide 610-1018, 610-1031, 610-1124

by Civco Medical Instruments Co., Inc. EUDAMEDGUDID

Active European Union and United States

Ref 610-1018

Regulatory status

as of 27 Oct 2026

Recall ongoing. 1 ongoing FDA recall. See recalls

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0841436101TD101B1NA Basic UDI-DIDate16 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10841436101650 UDI-DIDate22 Aug 2017ListedStatusIn distribution

Coverage

2 jurisdictions

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaSwedenFinlandFinlandSwedenFinlandFinlandSwedenSwedenLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyGermanyPolandPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaPolandFranceFranceAustriaHungaryRomaniaFranceFranceSloveniaBulgariaPortugalSpainSpainItalySpainSpainCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

7 recalls · 1 ongoing · FDA

    • Ongoing Z-1892-2025 FDA Class II initiated 1 May 2025

    During the attachment of the needle guide to the covered probe, the tight tolerance and fit of the needle guide can cause a pinhole breach in the transducer cover when latching the guide in place.

    • Terminated Z-2888-2018 FDA Class II initiated 23 Feb 2018

    A cover failed leak testing during validation testing of new needle guides from a replacement tool.

  • 5 recalls, same reason

    • Terminated Z-0286-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0288-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0289-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0290-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0287-2016 FDA Class II initiated 21 Oct 2015

    Sterility of the product cannot be assured.

Specification

EUDAMED · GUDID

Trade Name
AccuSITE Needle Guide
Generic Name
Needle guide, single-use
Device Name
General Purpose Guidance – Out-of-Plane, Fixed Angle (Accusite guide)
Model / Ref / Catalog
610-1018, 610-1031, 610-1124
Primary DI / UDI-DI
10841436101650
Basic UDI-DI
0841436101TD101B1NA
510(k) Number
FDA Product Code
ITX
EMDN Code
A018002 Needle guides
GMDN Term
Needle guide, single-use
Device Class
Class IIa EUDAMED
Class II GUDID
Regulation Number
892.1570
Market of Registration
Germany
Commercial Distribution
In Commercial Distribution
Sterilization Method
Ethylene Oxide
Size
Length — 5.5 Inch
Width — 3.3 Inch

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / ReferenceEUDAMED
610-1018
GUDID
610-1018, 610-1031, 610-1124
Device ClassEUDAMED
Class IIa
GUDID
Class II

Other devices from Civco Medical Instruments Co., Inc.

See all devices from Civco Medical Instruments Co., Inc. →

Properties

  • Sterile
  • Single Use
  • Prescription Use
  • Convenience Kit
  • Lot / Batch Number
  • Expiration Date
  • Manufacturing Date

Other properties (17)

  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Measuring Function: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No