Advanced Perfusion System 1

by Terumo Cardiovascular Systems Corporation 5 variants

510(k) K172220

Advanced Perfusion System 1 is a medical device (FDA Class II; FDA product code DTQ, Console, Heart-Lung Machine, Cardiopulmonary Bypass) made by Terumo Cardiovascular Systems Corporation, cleared under FDA 510(k) K172220 on 17 Aug 2017, active as of 11 Oct 2026. 14 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

14 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 11 Oct 2026.

Regulatory status

as of registry sync 11 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK172220 Date17 Aug 2017ClearedStatusActive

Official records

From the FDA record

Received by the FDA
24 Jul 2017
FDA decision
17 Aug 2017 (Substantially Equivalent)
FDA review time
24 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K172220 (openFDA), as read on 11 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

14 recalls · FDA

    • Terminated Z-2350-2021 FDA Class II initiated 8 Jun 2021

    intermittent failure causes a blender initialization fault upon start-up, or during an EPGS calibration attempt following the 15-minute warm-up period. The control sliders on the Central Control Monitor (CCM) are disabled and the gas system can only be controlled by the local control knobs

  • 3 recalls, same reason

    • Terminated Z-2959-2020 FDA Class II initiated 25 Aug 2020
    • Terminated Z-2960-2020 FDA Class II initiated 25 Aug 2020
    • Terminated Z-2961-2020 FDA Class II initiated 25 Aug 2020

    Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.

  • 4 recalls, same reason

    • Terminated Z-1108-2020 FDA Class II initiated 10 Jan 2020
    • Terminated Z-1109-2020 FDA Class II initiated 10 Jan 2020
    • Terminated Z-1110-2020 FDA Class II initiated 10 Jan 2020
    • Terminated Z-1111-2020 FDA Class II initiated 10 Jan 2020

    These roller pumps were assembled with pump shafts that may fail at the location of the thread where a locknut is installed. The failure is associated with a noise that is atypical of roller pump operation. The noise is caused when an unsecured shaft end contacts the rotating pulley of the roller pump. Prolonged use of a roller pump in this condition could lead to an eventual pump stop, resulting in the inability to create pump flow due to pulley loosening and drive belt damage.

    • Terminated Z-1337-2019 FDA Class II initiated 18 Apr 2019

    The gas flow rate output of the EPGS may be inaccurate due to a defect in the internal flowmeter.

    • Terminated Z-1769-2019 FDA Class II initiated 17 Oct 2018

    An intermittent failure which causes a blender initialization fault upon start-up or during an EPGS calibration attempt leads to the Central Control Monitor control sliders being disabled, such that the gas system can only be controlled by the local control knobs.

    • Terminated Z-0176-2019 FDA Class II initiated 13 Sep 2018

    The service manual was not updated at the time of the release of software version 1.30.

    • Terminated Z-3242-2018 FDA Class II initiated 28 Aug 2018

    Screws on a Terumo Advanced Perfusion System 1 Power Manager Board (the base unit circuit board) were not torqued to specification. It is possible that a screw which has not been properly torqued can go undetected during manufacturing testing and may loosen over time, resulting in the potential for an electrical short in the system.

    • Terminated Z-3243-2018 FDA Class II initiated 28 Aug 2018

    Screws on a Terumo Advanced Perfusion System 1 Power Manager Board (the base unit circuit board) were not torqued to specification. It is possible that a screw which has not been properly torqued can go undetected during manufacturing testing and may loosen over time, resulting in the potential for an electrical short in the system

    • Terminated Z-1478-2018 FDA Class II initiated 19 Jan 2018

    Inaccurrate flow readings. Depending on the degree of inaccuracy, this issue may not be easy for the user to detect during setup or use (for example, following a Flow Probe relocation or manipulation).

Timeline

15 dated events

  1. Recall initiated FDA recalls Z-1769-2019
  2. Recall initiated FDA recalls Z-1337-2019
  3. Recall initiated FDA recalls Z-1108-2020
  4. Recall initiated FDA recalls Z-1109-2020
  5. Recall initiated FDA recalls Z-1110-2020
  6. Recall initiated FDA recalls Z-1111-2020
  7. Recall initiated FDA recalls Z-2959-2020
  8. Recall initiated FDA recalls Z-2960-2020
  9. Recall initiated FDA recalls Z-2961-2020
  10. Recall initiated FDA recalls Z-2350-2021

5 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
DTQ
Device class
Class II
Regulation
21 CFR Part 870.4220
Advisory committee
Cardiovascular
FDA decision
SESE Substantially Equivalent