Advanced Perfusion System 1
by Terumo Cardiovascular Systems Corporation 5 variants
510(k) K172220
Advanced Perfusion System 1 is a medical device (FDA Class II; FDA product code DTQ, Console, Heart-Lung Machine, Cardiopulmonary Bypass) made by Terumo Cardiovascular Systems Corporation, cleared under FDA 510(k) K172220 on 17 Aug 2017, active as of 11 Oct 2026. 14 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK172220 | Date17 Aug 2017 | StatusActive |
Official records
- FDA 510(k) database K172220
From the FDA record
- Received by the FDA
- 24 Jul 2017
- FDA decision
- 17 Aug 2017 (Substantially Equivalent)
- FDA review time
- 24 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Terminated Z-2350-2021
intermittent failure causes a blender initialization fault upon start-up, or during an EPGS calibration attempt following the 15-minute warm-up period. The control sliders on the Central Control Monitor (CCM) are disabled and the gas system can only be controlled by the local control knobs
-
- Terminated Z-2959-2020
- Terminated Z-2960-2020
- Terminated Z-2961-2020
Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.
-
- Terminated Z-1108-2020
- Terminated Z-1109-2020
- Terminated Z-1110-2020
- Terminated Z-1111-2020
These roller pumps were assembled with pump shafts that may fail at the location of the thread where a locknut is installed. The failure is associated with a noise that is atypical of roller pump operation. The noise is caused when an unsecured shaft end contacts the rotating pulley of the roller pump. Prolonged use of a roller pump in this condition could lead to an eventual pump stop, resulting in the inability to create pump flow due to pulley loosening and drive belt damage.
-
- Terminated Z-1337-2019
The gas flow rate output of the EPGS may be inaccurate due to a defect in the internal flowmeter.
-
- Terminated Z-1769-2019
An intermittent failure which causes a blender initialization fault upon start-up or during an EPGS calibration attempt leads to the Central Control Monitor control sliders being disabled, such that the gas system can only be controlled by the local control knobs.
-
- Terminated Z-0176-2019
The service manual was not updated at the time of the release of software version 1.30.
-
- Terminated Z-3242-2018
Screws on a Terumo Advanced Perfusion System 1 Power Manager Board (the base unit circuit board) were not torqued to specification. It is possible that a screw which has not been properly torqued can go undetected during manufacturing testing and may loosen over time, resulting in the potential for an electrical short in the system.
-
- Terminated Z-3243-2018
Screws on a Terumo Advanced Perfusion System 1 Power Manager Board (the base unit circuit board) were not torqued to specification. It is possible that a screw which has not been properly torqued can go undetected during manufacturing testing and may loosen over time, resulting in the potential for an electrical short in the system
-
- Terminated Z-1478-2018
Inaccurrate flow readings. Depending on the degree of inaccuracy, this issue may not be easy for the user to detect during setup or use (for example, following a Flow Probe relocation or manipulation).
Timeline
- Recall initiated FDA recalls Z-1769-2019
- Recall initiated FDA recalls Z-1337-2019
- Recall initiated FDA recalls Z-1108-2020
- Recall initiated FDA recalls Z-1109-2020
- Recall initiated FDA recalls Z-1110-2020
- Recall initiated FDA recalls Z-1111-2020
- Recall initiated FDA recalls Z-2959-2020
- Recall initiated FDA recalls Z-2960-2020
- Recall initiated FDA recalls Z-2961-2020
- Recall initiated FDA recalls Z-2350-2021
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- DTQ
- Device class
- Class II
- Regulation
- 21 CFR Part 870.4220
- Advisory committee
- Cardiovascular
- FDA decision
- SESE Substantially Equivalent
Similar devices
Other devices filed under FDA product code DTQ (Console, Heart-Lung Machine, Cardiopulmonary Bypass).
- STOCKERT S5 SYSTEM, STOCKERT GAS BLENDER by Sorin Group Deutschland GmbH
- SIII ALARM AMPLIFIER by Stockert Instrumente GmbH
- LIFEBRIDGE B2T, MODEL 7001 by Lifebridge Medizintechnik AG
- Essenz HLM, Essenz ILBM by LivaNova Deutschland GmbH
- MODIFICATION TO STOCKERT S5 SYSTEM by Sorin Group Deutschland GmbH
- CENTRIMED SYSTEM 1 W/MANUAL PUMP DRIVE by Centrimed Corp.
- MAQUET CARDIOHELP FBS 3/8" x 3/32" L0.9 70104.8001 by Maquet Cardiopulmonary AG
- Sarns 8000 Modular Perfusion System by 3M Health Care, Sarns
- SARNES HELP by 3M Health Care, Sarns
- Medtronic Performer CpB, Model R51, Pcpb by Rand S.R.L.