Apexpro Telemetry Systems
by GE Medical Systems Information Technologies
510(k) K080251
Apexpro Telemetry Systems is a medical device (FDA Class II; FDA product code MHX, Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)) made by GE Medical Systems Information Technologies, cleared under FDA 510(k) K080251 on 20 Jun 2008, active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK080251 | Date20 Jun 2008 | StatusActive |
Official records
- FDA 510(k) database K080251
From the FDA record
- Received by the FDA
- 31 Jan 2008
- FDA decision
- 20 Jun 2008 (Substantially Equivalent)
- FDA review time
- 141 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-2242-2026
GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the CARESCAPE Central Station or CIC Pro Clinical Information Center (Central Station).
-
- Ongoing Z-0175-2020
May not provide visual and/or audible alarms at the CARESCAPE Central Station or Clinical Information Center monitor for ECG arrhythmias, ECG LEADS FAIL or Pulse Oximetry (SpO2) under certain conditions.
-
- Terminated Z-0725-2020
When connected to the Mission Critical (MC) and /or Information Exchange (IX) networks, certain versions of the CARESCAPE Telemetry Server, ApexPro Telemetry Server, CARESCAPE Central Station (CSCS) version 1 and Central Information Center (CIC) systems were identified to have vulnerabilities to a cyber-attack.
-
- Terminated Z-1522-2011
GE Healthcare has become aware of a potential for loss of patient monitoring when ApexPro Telemetry System is used in conjunction with a mirrored view CARESCAPE CIC Pro in combination monitoring mode (combo mode). The safety issue includes the potential for a delay in annunciation of audible alarms when used in combo mode, and may result in the delay of treatment of a cardiac event.
Timeline
- Cleared FDA 510(k) K080251
- Recall initiated FDA recalls Z-1522-2011
- Recall initiated FDA recalls Z-0175-2020
- Recall initiated FDA recalls Z-0725-2020
- Recall initiated FDA recalls Z-2242-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- MHX
- Device class
- Class II
- Regulation
- 21 CFR Part 870.1025
- Advisory committee
- Cardiovascular
- FDA decision
- SESE Substantially Equivalent
Devices cleared under K080251
Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.
| UDI-DI | Size and differences | |||
|---|---|---|---|---|
| ApexPro 600 MHz Receiver | 600 MHz Receiver | 00840682108799 | — | On the market |
| ApexPro CH Transmitter | CH Transmitter | 00840682108928 | — | No longer on the market |
| ApexPro FH Transceiver | FH Transceiver | 00840682109024 | — | No longer on the market |
| CARESCAPE T14 Transmitter | T14 Transmitter | 00840682109383 | — | No longer on the market |
| CARESCAPE Telemetry Server V4 | Telemetry Server V4 | 00840682109260 | — | No longer on the market |
| CARESCAPE Telemetry Server v4 upgrade | Telemetry Server v4 upgrade | 00840682108775 | — | No longer on the market |
| CARESCAPE Telemetry Server V6 | V6 | 00198953205716 | — | On the market |
Similar devices
Other devices filed under FDA product code MHX (Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)).
- Mortara Surveyor Telemetry Central Station by MORTARA INSTRUMENT, INC.
- PHILIPS INTELLIVUE PATIENT MONITOR, MODELS MP40 & MP50 by Philips Medizin Systeme Boeblingen GmbH
- HP VIRIDIA CMS PATIENT MONITOR WITH EEG PARAMETER, MODEL M1027A by Hewlett-Packard Co.
- Omni-Trak Model 3150 Series Patient Monitoring System by Invivo Research, Inc.
- Intellivue MX40 Patient Monitor by Philips Medical Systems
- BioHarness by Zephyr Technology Corporation
- Infinity CentralStation Wide by Draeger Medical Systems, Inc.
- Vital Signs Monitor; Advisor Model # BCI 9200 by Bci Intl., Inc.
- PHYSIOLOGICAL MONITOR, PATIENT MONITOR by Philips Medizinsysteme Boeblingen GmbH, Cardiac AN
- Next Generation NetKonnect by Nihon Kohden Digital Health Solutions LLC
Other devices from GE Medical Systems Information Technologies, Inc.
See all devices from GE Medical Systems Information Technologies, Inc. →