Brightview VCT Imaging System

by Philips Medical Systems (Cleveland), Inc.

510(k) K080927

Brightview VCT Imaging System is a medical device (FDA Class II; FDA product code KPS, System, Tomography, Computed, Emission) made by Philips Medical Systems (Cleveland), Inc., cleared under FDA 510(k) K080927 on 11 Apr 2008, active as of 22 Oct 2026. 30 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

4 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK080927 Date11 Apr 2008ClearedStatusActive

Official records

From the FDA record

Received by the FDA
2 Apr 2008
FDA decision
11 Apr 2008 (Substantially Equivalent)
FDA review time
9 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K080927 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

30 recalls · 4 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-0930-2024 FDA Class I initiated 15 Dec 2023
    • Ongoing Z-0931-2024 FDA Class I initiated 15 Dec 2023

    Detector may unexpectedly fall due to a component failure. If the detector is positioned below center of gantry, there is a potential for abrasion, contusion, laceration, and/or fracture to the patient's lower limbs, as well as an interruption to normal system operation. If detector is positioned above center of gantry, there may be an interruption to normal system operation.

  • 2 recalls, same reason

    • Ongoing Z-0678-2024 FDA Class II initiated 30 Nov 2023
    • Ongoing Z-0679-2024 FDA Class II initiated 30 Nov 2023

    While using Pre-Programmed Motion during an extrinsic quality assurance scan, a gap is created between the patient support and the detector, which may present a potential extremity entrapment hazard. Risk to patients may include fracture, body part loss of function/debilitation, muscle or ligament sprain or strain, laceration, crush injury, abrasion, or contusion.

  • 3 recalls, same reason

    • Terminated Z-2009-2019 FDA Class II initiated 10 Jun 2019
    • Terminated Z-2011-2019 FDA Class II initiated 10 Jun 2019
    • Terminated Z-2010-2019 FDA Class II initiated 10 Jun 2019

    An issue with the handcontroller may result in either spontaneous uncommanded motions or continued motion after the buttons were released.

  • 4 recalls, same reason

    • Terminated Z-1753-2017 FDA Class III initiated 24 Feb 2017
    • Terminated Z-1752-2017 FDA Class II initiated 24 Feb 2017
    • Terminated Z-1750-2017 FDA Class II initiated 24 Feb 2017
    • Terminated Z-1751-2017 FDA Class II initiated 24 Feb 2017

    The brake hub was not engaging with the gear box shaft due to an error in the assembly of components within the brake hub mechanism after service, causing the detector to backdrive.

  • 3 recalls, same reason

    • Terminated Z-1481-2017 FDA Class II initiated 31 Jan 2017
    • Terminated Z-1480-2017 FDA Class II initiated 31 Jan 2017
    • Terminated Z-1479-2017 FDA Class II initiated 31 Jan 2017

    Four issues: 1. Motion controller problem stops scan and no data image produced. 2. Door interlock switch problem disables CT scan. 3. Detector contacts head holder when performing Patient Unload. 4. JETStream freezes during gated planar scan

  • 2 recalls, same reason

    • Terminated Z-1186-2017 FDA Class II initiated 23 Dec 2016
    • Terminated Z-1187-2017 FDA Class II initiated 23 Dec 2016

    The intended use listed in the English and localized language IFUs for BrightView XCT systems did not match the intended use documented in the 510K submission.

  • 2 recalls, same reason

    • Terminated Z-2737-2016 FDA Class II initiated 25 May 2016
    • Terminated Z-2736-2016 FDA Class II initiated 25 May 2016

    The firm became aware of an issue where during a non-Auto Body Contouring (ABC), non-circular, rel-180 scan, the detector may come in contact with the patient. The issue was caused by a software defect in the workflow setup script.

    • Terminated Z-1022-2016 FDA Class II initiated 17 Dec 2015

    The firm discovered four issues with the BrightView Family systems. Issue 1: During a cardiac non-Auto Body Contouring (ABC) scan, using Cardiac High Resolution (CHR) collimators, the collimator may come in contact with the bottom edge of the patient pallet. If this occurs, collision sensors would pause the scan. Issue 2: During a scan, the gantry motion may halt prematurely. This cause

    • Terminated Z-1792-2015 FDA Class II initiated 6 Mar 2015

    The firm was notified that the failure of the UPS accessory devices used in conjunction with Computed Tomography X-ray systems and Diagnostic Imaging systems. may result in battery acid leakage, overheating and/or emission of fumes.

    • Terminated Z-1011-2015 FDA Class II initiated 12 Nov 2014

    Unintended detector and gantry movement due to software issues.

    • Terminated Z-0450-2015 FDA Class II initiated 4 Nov 2014

    Software issues

    • Terminated Z-1982-2014 FDA Class II initiated 23 Jun 2014

    Flat Panel Display (FPD) failed to remain securely locked in the deployed position.

    • Terminated Z-1074-2014 FDA Class II initiated 19 Dec 2013

    Three problems were reported to the firm: When positioning for a relative 180 degree non circular acquisition the second (bottom) detector was not positioned correctly causing an inappropriate rotation orbit calculation. When the acquisition was started and the detectors began to move into position, the incorrect calculation resulted in the detectors coming in contact with the patient. As

    • Terminated Z-0203-2015 FDA Class II initiated 23 Oct 2013

    It was discovered the CT portion of the scan was interrupted ( stopping the CT exposure at the time of interruption) and did not complete successfully.

    • Terminated Z-0089-2014 FDA Class II initiated 3 Sep 2013

    Philips received reports from the field that the Flat Panel Detector (FPD) does not always remain securely latched in the stowed position.

  • 2 recalls, same reason

    • Terminated Z-2948-2011 FDA Unclassified (pre-2012) initiated 15 Jun 2011
    • Terminated Z-2949-2011 FDA Unclassified (pre-2012) initiated 15 Jun 2011

    Non-conformances with BrightView X/XCT systems running version 2.0.1 including data transfer, XCT acquisition, Pixel Mask for image reconstruction and table moving incorrectly.

  • 2 recalls, same reason

    • Terminated Z-2155-2011 FDA Unclassified (pre-2012) initiated 28 Mar 2011
    • Terminated Z-2156-2011 FDA Unclassified (pre-2012) initiated 28 Mar 2011

    The current Headholder to support Bright View XCT brain imaging allowed for imaging the brain but doe allow for imaging of the associated shoulder/neck area of the body.

Timeline

31 dated events

  1. Recall initiated FDA recalls Z-1752-2017
  2. Recall initiated FDA recalls Z-1750-2017
  3. Recall initiated FDA recalls Z-1751-2017
  4. Recall initiated FDA recalls Z-2009-2019
  5. Recall initiated FDA recalls Z-2011-2019
  6. Recall initiated FDA recalls Z-2010-2019
  7. Recall initiated FDA recalls Z-0678-2024
  8. Recall initiated FDA recalls Z-0679-2024
  9. Recall initiated FDA recalls Z-0930-2024
  10. Recall initiated FDA recalls Z-0931-2024

21 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
KPS
Device class
Class II
Regulation
21 CFR Part 892.1200
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code KPS (System, Tomography, Computed, Emission).

Other devices from Philips Medical Systems (Cleveland), Inc.

See all devices from Philips Medical Systems (Cleveland), Inc. →