Skip to content

BX2 Biopsy Bracket 680-110

by Civco Medical Instruments Co., Inc.

Ref 680-110

BX2 Biopsy Bracket 680-110 is an ultrasound imaging system tracking positioner (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., registered in EUDAMED on 18 May 2026 (Basic UDI-DI 0841436101TD101A4ND), cleared under FDA 510(k) K093713 on 19 Jan 2010 and listed in FDA GUDID since 22 Aug 2017 (UDI-DI 00841436107600), active as of 23 Oct 2026. 7 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K093713

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0841436101TD101A4ND Basic UDI-DI 00841436107600UDI-DIDate18 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00841436107600 UDI-DI Date22 Aug 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK093713 Date19 Jan 2010DecidedStatusActive

Official records

From the FDA record

Device description
Reusable non-sterile bracket for use with Toshiba PVT-382BT transducers
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0841436101TD101A4ND registered 18 May 2026 Active
  • FDA 510(k) K093713 decided 19 Jan 2010 Active
  • FDA GUDID UDI-DI 00841436107600 listed 22 Aug 2017 Listed

Recalls

7 recalls · 1 ongoing · FDA

    • Ongoing Z-1892-2025 FDA Class II initiated 1 May 2025

    During the attachment of the needle guide to the covered probe, the tight tolerance and fit of the needle guide can cause a pinhole breach in the transducer cover when latching the guide in place.

    • Terminated Z-2888-2018 FDA Class II initiated 23 Feb 2018

    A cover failed leak testing during validation testing of new needle guides from a replacement tool.

  • 5 recalls, same reason

    • Terminated Z-0286-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0288-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0289-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0290-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0287-2016 FDA Class II initiated 21 Oct 2015

    Sterility of the product cannot be assured.

Timeline

10 dated events

  1. Cleared FDA 510(k) K093713
  2. Recall initiated FDA recalls Z-0286-2016
  3. Recall initiated FDA recalls Z-0288-2016
  4. Recall initiated FDA recalls Z-0289-2016
  5. Recall initiated FDA recalls Z-0290-2016
  6. Recall initiated FDA recalls Z-0287-2016
  7. Listed FDA GUDID 00841436107600
  8. Recall initiated FDA recalls Z-2888-2018
  9. Recall initiated FDA recalls Z-1892-2025
  10. Registered EUDAMED 0841436101TD101A4ND

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
BX2 Biopsy Bracket
Generic name
Ultrasound imaging system tracking positioner, reusable
Device name
General Purpose Guidance – In-Plane, Fixed Angle (BX2 guide)
Model / Ref / Catalog
680-110
Primary DI / UDI-DI
00841436107600
Basic UDI-DI
0841436101TD101A4ND
Direct marketing DI
20841436115395
510(k) Number
FDA product code
ITX
EMDN code
A018002 Needle guides
GMDN term
Ultrasound imaging system tracking positioner, reusable
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1570
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Size
Length — 1.5 Inch
Width — 1.1 Inch

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under NEEDLE GUIDES.

Other devices from Civco Medical Instruments Co., Inc.

See all devices from Civco Medical Instruments Co., Inc. →

Properties

  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Manufacturing date
Other properties (21, all answered No)