BX2 Needle Guide 680-112
by Civco Medical Instruments Co., Inc.
Ref 680-112
BX2 Needle Guide 680-112 is a needle guide (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., registered in EUDAMED on 18 May 2026 (Basic UDI-DI 0841436101TD101A4ND), cleared under FDA 510(k) K093713 on 19 Jan 2010 and listed in FDA GUDID since 22 Aug 2017 (UDI-DI 10841436107614), active as of 25 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0841436101TD101A4ND 10841436107614 | Date18 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number10841436107614 | Date22 Aug 2017 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK093713 | Date19 Jan 2010 | StatusActive |
Official records
- EUDAMED public site 0841436101TD101A4ND
- AccessGUDID record 10841436107614
- FDA 510(k) database K093713
From the FDA record
- Device description
- Sterile needle guide with (8.9 x 91.5cm) telescopically-folded CIV-Flex™ cover for use with Toshiba PVT-382BT transducer
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile; sterilise before use (Ethylene Oxide)
Across registries
- EUDAMED Basic UDI-DI 0841436101TD101A4ND registered 18 May 2026 Active
- FDA 510(k) K093713 decided 19 Jan 2010 Active
- FDA GUDID UDI-DI 10841436107614 listed 22 Aug 2017 Listed
Recalls
-
- Ongoing Z-1892-2025
During the attachment of the needle guide to the covered probe, the tight tolerance and fit of the needle guide can cause a pinhole breach in the transducer cover when latching the guide in place.
-
- Terminated Z-2888-2018
A cover failed leak testing during validation testing of new needle guides from a replacement tool.
-
- Terminated Z-0286-2016
- Terminated Z-0288-2016
- Terminated Z-0289-2016
- Terminated Z-0290-2016
- Terminated Z-0287-2016
Sterility of the product cannot be assured.
Timeline
- Cleared FDA 510(k) K093713
- Recall initiated FDA recalls Z-0286-2016
- Recall initiated FDA recalls Z-0288-2016
- Recall initiated FDA recalls Z-0289-2016
- Recall initiated FDA recalls Z-0290-2016
- Recall initiated FDA recalls Z-0287-2016
- Listed FDA GUDID 10841436107614
- Recall initiated FDA recalls Z-2888-2018
- Recall initiated FDA recalls Z-1892-2025
- Registered EUDAMED 0841436101TD101A4ND
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- BX2 Needle Guide
- Generic name
- Needle guide, single-use
- Device name
- General Purpose Guidance – In-Plane, Fixed Angle (BX2 guide)
- Model / Ref / Catalog
- 680-112
- Primary DI / UDI-DI
- 10841436107614
- Basic UDI-DI
- 0841436101TD101A4ND
- 510(k) Number
- FDA product code
- ITX
- EMDN code
- A018002 Needle guides
- GMDN term
- Needle guide, single-use
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Ethylene Oxide
- Size
- Width — 4.9 CentimeterLength — 5.7 Centimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Sterilise before use | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 10841436107614: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under NEEDLE GUIDES.
- InnoFine JEM-070 by JingFang Precision Medical Device(Shenzhen) Co., Ltd.
- PEROUSE MEDICAL E63101DR VPEE63101DR by PEROUSE MEDICAL
- Single-Use Dual Biopsy Guide UA1329-S by BK MEDICAL APS
- Single-Use Endfire Biopsy Guide UA1323-S by BK MEDICAL APS
- InnoFine DGCK-0101 11109 by JingFang Precision Medical Device(Shenzhen) Co., Ltd.
- Needle Guide LNGC2022YX by Argon Medical Devices, Inc.
- Disposable Needle-guided Bracket Kit 1070003043 by Carbon (Shenzhen) Medical Device Co., Ltd.
- Surefire 28-TPU168 by Advance Medical Designs, Inc.
- SeeStar 20G 13320 by Apriomed AB
- Transperineal Template Grid 17G 28-TPG002 by Advance Medical Designs, Inc.