Skip to content

BX2 Needle Guide 680-112

by Civco Medical Instruments Co., Inc.

Ref 680-112

BX2 Needle Guide 680-112 is a needle guide (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., registered in EUDAMED on 18 May 2026 (Basic UDI-DI 0841436101TD101A4ND), cleared under FDA 510(k) K093713 on 19 Jan 2010 and listed in FDA GUDID since 22 Aug 2017 (UDI-DI 10841436107614), active as of 25 Oct 2026. 7 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K093713

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0841436101TD101A4ND Basic UDI-DI 10841436107614UDI-DIDate18 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number10841436107614 UDI-DI Date22 Aug 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK093713 Date19 Jan 2010DecidedStatusActive

Official records

From the FDA record

Device description
Sterile needle guide with (8.9 x 91.5cm) telescopically-folded CIV-Flex™ cover for use with Toshiba PVT-382BT transducer
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0841436101TD101A4ND registered 18 May 2026 Active
  • FDA 510(k) K093713 decided 19 Jan 2010 Active
  • FDA GUDID UDI-DI 10841436107614 listed 22 Aug 2017 Listed

Recalls

7 recalls · 1 ongoing · FDA

    • Ongoing Z-1892-2025 FDA Class II initiated 1 May 2025

    During the attachment of the needle guide to the covered probe, the tight tolerance and fit of the needle guide can cause a pinhole breach in the transducer cover when latching the guide in place.

    • Terminated Z-2888-2018 FDA Class II initiated 23 Feb 2018

    A cover failed leak testing during validation testing of new needle guides from a replacement tool.

  • 5 recalls, same reason

    • Terminated Z-0286-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0288-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0289-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0290-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0287-2016 FDA Class II initiated 21 Oct 2015

    Sterility of the product cannot be assured.

Timeline

10 dated events

  1. Cleared FDA 510(k) K093713
  2. Recall initiated FDA recalls Z-0286-2016
  3. Recall initiated FDA recalls Z-0288-2016
  4. Recall initiated FDA recalls Z-0289-2016
  5. Recall initiated FDA recalls Z-0290-2016
  6. Recall initiated FDA recalls Z-0287-2016
  7. Listed FDA GUDID 10841436107614
  8. Recall initiated FDA recalls Z-2888-2018
  9. Recall initiated FDA recalls Z-1892-2025
  10. Registered EUDAMED 0841436101TD101A4ND

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
BX2 Needle Guide
Generic name
Needle guide, single-use
Device name
General Purpose Guidance – In-Plane, Fixed Angle (BX2 guide)
Model / Ref / Catalog
680-112
Primary DI / UDI-DI
10841436107614
Basic UDI-DI
0841436101TD101A4ND
510(k) Number
FDA product code
ITX
EMDN code
A018002 Needle guides
GMDN term
Needle guide, single-use
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1570
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide
Size
Width — 4.9 Centimeter
Length — 5.7 Centimeter

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II
Sterilise before useEUDAMED
No
GUDID
Yes

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Sterilise before use UDI-DI 10841436107614: EUDAMED states No, FDA GUDID states Yes.

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under NEEDLE GUIDES.

Other devices from Civco Medical Instruments Co., Inc.

See all devices from Civco Medical Instruments Co., Inc. →

Properties

  • Supplied sterile
  • Sterilise before use NoEUDAMEDYesGUDID
  • Single use
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (17, all answered No)